TC-120F (Z) type high negative pressure air heavy metal particle sampler

NegotiableUpdate on 03/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
TC-120F (Z) High Negative Pressure Air Heavy Metal Particle Sampler Product Introduction TC-120F (Z) Air Heavy Metal Sampler is suitable for collecting heavy metal particles (TSP, PM10, PM2.5, etc.) in the atmosphere. This instrument adopts high-tech in the fields of sensors, new materials, etc., with reliable quality, stable performance, and long service life. Suitable for routine monitoring and environmental evaluation of the atmosphere by relevant departments such as factories, mines, environmental protection, labor, health, scientific research, meteorology, etc. 2、 The TC-120F (Z) high negative pressure air heavy metal particle sampler adopts biao zhunHJ/T 374-2007 "Technical Requirements and Testing Methods for Total Suspended Particle Samplers" JJG 943-2011 "Total Suspended Particle Samplers" HJ 618-2011 "Determination of Weight Method for PM10 and PM2.5 in Environmental Air" HJ/T 93-2013 "Technical Requirements and Testing Methods for Environmental Air Particle (PM10 and PM2.5) Samplers" Q/0213TWB 001-2014 Enterprise biao zhun III. Main Features: Brushless high negative pressure sampling pump, can overcome 20kPa resistance at a flow rate of 100L/min; Electronic flowmeter, constant current sampling; Equipped with a real-time clock, it can be set for timed sampling with multiple sampling intervals; The TSP/PM10/PM2.5 sampling head is made of aluminum alloy material and has anti-static adsorption; Automatic measurement of temperature and air pressure, automatic calculation of standard sampling volume; Small size, light weight, easy to carry; Large sized Chinese dot matrix LCD screen with automatic adjustment .....
Product Details
TC-120F(Z)Type high negative pressure air heavy metal particle sampler

1 TC-120F(Z)Product Introduction of High Negative Pressure Air Heavy Metal Particle Sampler
The TC-120F (Z) air heavy metal sampler is suitable for collecting heavy metal particles (TSP, PM10, PM2.5, etc.) in the atmosphere. This instrument adopts high-tech in the fields of sensors, new materials, etc., with reliable quality, stable performance, and long service life. Suitable for routine monitoring and environmental evaluation of the atmosphere by relevant departments such as factories, mines, environmental protection, labor, health, scientific research, meteorology, etc.
II TC-120F(Z)The high negative pressure air heavy metal particle sampler adopts biao zhun
HJ/T 374-2007 Technical Requirements and Testing Methods for Total Suspended Particle Samplers
JJG 943-2011 "Total Suspended Particle Sampler"
HJ 618-2011 "Determination of PM10 and PM2.5 in ambient air by gravimetric method"
HJ/T 93-2013 "Technical Requirements and Detection Methods for Particulate Matter (PM10 and PM2.5) Samplers in Environmental Air"
Q/0213TWB 001-2014 Enterprise biao zhun
3、 Main features
Brushless high negative pressure sampling pump, capable of overcoming 20kPa resistance at a flow rate of 100L/min;
Electronic flowmeter, constant current sampling;
Equipped with a real-time clock, it can be set for timed sampling with multiple sampling intervals;
The TSP/PM10/PM2.5 sampling head is made of aluminum alloy material and has anti-static adsorption;
Automatic measurement of temperature and air pressure, automatic calculation of standard sampling volume;
Small size, light weight, easy to carry;
Large size Chinese dot matrix LCD screen, automatically adjusts contrast, can work normally at minus 30 degrees Celsius;
Power off protection function, automatic sampling of incoming calls;
Sampling data can be printed or exported from a USB drive;
4、 Technical indicators

Main parameters parameter range resolution accuracy
sampling flow (60~130)L/min 0.1L/min Better than ± 2.5%
Traffic stability Better than ± 2.0%
Traffic repeatability Better than ± 2.0%
sampling time 1min~99h59min 1min Not exceeding ± 0.2%
Pre measurement pressure (-20~0)kPa 0.01kPa Better than ± 2.5%
Environmental atmospheric pressure (70~130)kPa 0.01kPa Better than ± 2.5%
Timed startup 24-hour clock
Equidistant sampling time Set freely within 99 hours and 59 minutes
Equal interval sampling frequency 1 to 99 times
noise <59dB(A)
Overall dimensions (W × D × H) mm 260×280×350
weight About 8.0 kg
power supply AC220V±10% 50HZ
power consumption <600W
Sampling head indicators
PM2.5 cutting characteristics Da50 = (2.5±0.2)μm 〥g = (1.2±0.1)μm
PM10 cutting characteristics Da50 = (10±0.5)μm 〥g = (1.5±0.1)μm
Entrance speed 0.3m/s
b/a 0.625
sampling flow 100L/min
Effective filter membrane diameter Ф80mm
connector M20×1.5
5、 Packing list
serial number name unit quantity Remarks
1 host Taiwan 1
2 Main aluminum box a 1
3 Attachment aluminum box a 1
4 TSP/PM10 sampling a 1
5 Fluoride sampling head (optional) a 1
6 power cord root 1
7 triangular bracket a 1
8 Sampling filter membrane box 1 glass fiber filters
9 Sampling filter membrane box 1 Polytetrafluoroethylene filter membrane
10 Filter membrane clamp box a 2
11 Product Manual copy 1
12 Product Qualification Certificate copy 1
13 Product Warranty Card copy 1