Supply original Italian GEFRAN pressure sensor TK series

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Italian GEFRAN pressure sensor is a device or apparatus that can sense pressure signals and convert them into usable output electrical signals according to certain rules. Pressure sensors typically consist of pressure sensitive components and signal processing units. According to different types of testing pressure, the original Italian GEFRAN pressure sensor TK series is supplied in the form of gauge pressure sensors, differential pressure sensors, and absolute pressure sensors.

Product Details

Supply original Italian GEFRAN pressure sensor TK seriesOverview:

The TK series is a pressure sensor used in high-temperature applications where the process temperature may reach 538 ° C (1000 ° F), such as high-temperature engineering polymers. The K series adopts the standard melt pressure principle and structure. Strain sensing technology is adhesive foil strain gauges. Almost incompressible sodium potassium (NaK) mixture is used for pressure transfer. NaK is a FDA approved safe (GRAS) substance. Application: As for FDA approval, the K series is suitable for mercury free, food and medical applications, processing special polymers, and high-tech polymers (538 ° C/1000 ° F).

Supply original Italian GEFRAN pressure sensor TK seriesDescription

Pressure range: 0-35 to 0-1000 bar/0-500 to 0-15000 psi accuracy<± 0.25% FS (H); <± 0.5% FS (meters)

The hydraulic transmission system with pressure signals ensures stability at operating temperature (NaK). Liquids that comply with the RoHS directive. NaK is defined as a safe substance (GRAS), and the number of NaK contained in each model is: K30 series (30mm 3) (0.00183 in 3), K31-K32-K33 series (40mm 3) (0.00244 in 3) 1/2-20UNF, M18x1.5 standard thread; Other types of Inconel 718 membranes with GTP+coating can be provided upon request, suitable for temperatures up to 538 ° C (1000 ° F) with GTP+coating for 15-5 PH membranes, suitable for temperatures up to 400 ° C (750 ° F) with Hastelloy C276 membranes, suitable for temperatures up to 300 ° C (570 ° F) with GTP+coating for 17-7 PH corrugated membranes, suitable for the range of 100bar-1500psi and below. Italian GEFRAN pressure sensor performance indicators:

Measurement medium: liquid or gas (non corrosive to stainless steel shell)

Range: 0-10MPa

Accuracy level: 0.1% FS, 0.5% FS (optional)

Stability performance: ± 0.05% FS/year; ± 0.1% FS/year

Output signal: RS485, 4~20mA (optional)

Overload capacity: 150% FS

Zero temperature coefficient: ± 0.01% FS/℃

Full temperature coefficient: ± 0.02% FS/℃

Correct installation method for GEFRAN pressure sensor in Italy:

(1) Verify the frequency response value of the pressure sensor under normal atmospheric pressure and standard temperature conditions using appropriate instruments.

(2) Verify the correctness of the coding of the pressure sensor and the corresponding frequency response signal.

2. Determine the specific installation location

In order to determine the number and specific installation location of the Italian GEFRAN pressure sensor, it is necessary to consider each inflation section of the inflation net.

(1) The pressure sensor must be installed along the cable and installed at the cable joint.

(2) Each cable should be equipped with no less than 4 pressure sensors, and the two pressure sensors near the telephone office should be no more than 200m apart.

(3) Install one at the beginning and one at the end of each cable.

(4) Each cable should have one branch point installed. If two branch points are close together (less than 100 meters), only one can be installed.

(5) One cable should be installed at the location where the cable laying method (overhead, underground) changes

(6) For cables without branches, due to the consistent cable program of the base line, the installation spacing of pressure sensors should not be more than 500m, and the total number should not be less than 4.

(7) In order to facilitate the determination of the fault point of the pressure sensor, in addition to installing the pressure sensor at the starting point, an additional one needs to be installed at a distance of 150-200m from the starting point. Of course, in the design, economic and technical factors must be considered. If the pressure sensor does not need to be installed, it should not be installed.