Supply of pulp flow meterThe measurement principle is based on Faraday's law of electromagnetic induction. The measuring tube of the flowmeter is a non-magnetic alloy short tube lined with insulating material. Two electrodes are fixed on the measuring tube by passing through the tube wall along the diameter direction. The electrode tip is basically flush with the inner surface of the lining. When the excitation coil is excited by bidirectional square wave pulses, a working magnetic field with a magnetic flux density of B will be generated in the direction perpendicular to the axis of the measuring tube. At this point, if a fluid with a certain conductivity flows through the measuring tube, an electromotive force E will be induced by cutting the magnetic field lines. The electromotive force E is proportional to the magnetic flux density B, which is the product of the inner diameter d of the measuring tube and the average flow velocity v. The electromotive force E (flow signal) is detected by the electrode and sent to the converter through a cable. After amplifying and processing the flow signal, the converter can display the fluid flow rate and output signals such as pulses and analog currents for flow control and regulation. In the equation E=KBdv, E represents the signal voltage (v) between the electrodesPulp flowmeterB - Magnetic flux density (T) d - Measuring tube inner diameter (m) v - Average flow velocity (m/s) In the equation, K and d are constants. Since the excitation current is constant, B is also constant. Therefore, from E=KBdv, it can be seen that the volume flow rate Q is proportional to the signal voltage E, that is, the signal voltage E induced by the flow velocity is linearly related to the volume Q. Therefore, as long as E is measured, the flow rate Q can be determined, which isPulp flowmeterThe basic working principle. According to E=KBdv, parameters such as temperature, density, pressure, conductivity, and liquid-solid composition ratio of the measured fluid medium will not affect the measurement results.

Pulp flow meterAs for the flow state, as long as it conforms to axisymmetric flow (such as laminar or turbulent flow), it will not affect the measurement results. Therefore, it is said thatPulp flowmeterIt is a true volumetric flowmeter. For manufacturers and users, the volumetric flow rate of any other conductive fluid medium can be measured without any correction as long as it is calibrated with ordinary water. This isPulp flowmeterOne outstanding advantage of this is that it is not found in any other flow meter. There are no active or obstructed components inside the measuring tube, so there is almost no pressure loss and it has * reliability.
Our advantages:
We implement a lifelong responsibility system for our products and always provide technical support and services.
Implement three guarantees for product quality, with a shelf life of12A month.
Free engineering and technical personnel for users to provide guidance on product usage, maintenance, and general troubleshooting
On site guidance for installation and debugging.
Regularly conduct follow-up visits and technical exchanges with users.
Prioritize providing product and technical support to project users.
JKM-LDESupply of pulp flow meter:
◆Nominal diameter: DN10~DN3000mm
◆Pulp flowmeter Nominal pressure: 0.6~4.0MPa (special pressure can be customized)
◆Accuracy: ± 0.5% of indication, optional ± 0.3% or ± 0.2% of indication
◆Pulp flowmeter Lining material: polytetrafluoroethylene, PFA, F46, Chloroprene rubber, high-temperature rubber
◆Pulp flowmeter Electrode form: standard type, type, replaceable type
◆Electrode Material: 316L, Hastelloy C, Titanium, Tantalum, Platinum Iridium, Alloy, Stainless Steel Coated with Tungsten Carbide
◆Medium temperature: Integrated type: -20℃- +60℃
◆Pulp flowmeter Split type: chloroprene rubber lining/polyurethane lining/PTFE lining/PFA lining/F46 lining
◆Pulp flowmeter Environmental temperature: -25℃- +60℃
◆Environmental humidity: 5-100% RH (relative humidity)
◆Dielectric conductivity: ≥ 20 μ S/cm
◆Measurement range: 1500:1
◆Structural form: integrated type, split type, immersive type, explosion-proof type
◆Protection level: IP65, IP68 optional
◆Pulp flowmeter Explosion proof mark: Exmd ∥ T4

Pulp flowmeter How to choose the right type
The selection of instruments is a very important task in instrument applications. Relevant data shows that 2/3 of instrument failures in practical applications are caused by incorrect selection or installation of instruments. Please pay special attention.
Pulp flowmeter Flow direction adjustment
The flow meter and flow direction regulations are described in Section 2.6.5. For separated flow meters, although installing sensors can ensure that the flow direction arrow is consistent with the actual positive direction on site. Due to issues with user wiring, the following situations may occur:
Equipped with a unidirectional output converter, the output displays zero or negative values when there is forward flow (such as 0mA for 0-10mA or 4mA for 4-20mA).
A converter with bidirectional display, which outputs negative display when there is positive flow. At this point, simply disconnect the power supply and adjust the positions of the two excitation lines (EXT+and EXT -) on one side to ensure that the output direction, actual forward flow direction, and arrow direction remain consistent.
Pulp flowmeterMain technical data: nominal diameter: DN6-3000mm
Nominal force: 0.6, 1.0, 1.6, 4.0 MPa (high pressure can be processed according to user requirements)
Accuracy: ± 0.2% ± 0.5% (indication error)
Measurement range (flow rate): 0-1m/s to 0-10m/s
Medium temperature: Split type -10 ℃~+80 ℃ (PTFE and F46 lining -40 ℃~+180 ℃) Integrated type -10 ℃~+80 ℃
Environmental temperature: -25 ℃~+60 ℃
Pulp flowmeterEnvironmental humidity: 5-100% RH (relative humidity)
Dielectric conductivity: greater than 20 μ S/cm
Installation: integrated type, split type
IIIPulp flowmeterflow range
Diameter (mm) |
10 |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
Small flow rate (m3/h) |
0.02 |
0.06 |
0.12 |
0.16 |
0.29 |
0.452 |
0.7 |
1.19 |
Common range (m3/h) |
1 |
2 |
4 |
6 |
9 |
15 |
22 |
35 |
High flow rate (m3/h) |
4.24 |
9.54 |
16.96 |
26.5 |
43.42 |
67.85 |
106 |
179 |
Diameter (mm) |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
350 |
Small flow rate (m3/h) |
1.8 |
2.82 |
4.41 |
6.36 |
11.3 |
17.6 |
25.4 |
34.6 |
Common range (m3/h) |
55 |
85 |
130 |
190 |
340 |
530 |
750 |
1000 |
High flow rate (m3/h) |
271 |
424 |
662 |
954 |
1690 |
2650 |
3810 |
5196 |
Diameter (mm) |
400 |
450 |
500 |
550 |
600 |
700 |
800 |
900 |
Small flow rate (m3/h) |
45.2 |
57.2 |
77.6 |
85.5 |
101 |
138 |
180 |
229 |
Common range (m3/h) |
1200 |
1400 |
1700 |
2000 |
2500 |
2800 |
3600 |
4500 |
High flow rate (m3/h) |
6780 |
8570 |
10600 |
12800 |
15200 |
20700 |
27100 |
34300 |

Pulp flowmeterGrid code |
explanation |
|
enterprise standard |
JKM |
Kaiming |
Instrument type |
LDE |
Intelligent electromagnetic flowmeter |
Instrument type |
LDM |
Ordinary electromagnetic flowmeter |
Path code |
-XXX |
Example: 100 represents DN100. If the diameter is followed by I, it means insertion type, and AI means adjustable insertion type |
Electrode form |
-1 |
Standard fixed type |
2 |
Scraping type |
|
3 |
Removable and replaceable |
|
electrode material |
0 |
stainless steel |
1 |
Platinum Pt |
|
2 |
Ha Shi B (HB) |
|
3 |
钽Ta |
|
4 |
Titanium Ti |
|
5 |
Ha Shi C (HC) |
|
Lining material |
3 |
neoprene |
4 |
Polyurethane rubber |
|
5 |
F4 |
|
6 |
F46 |
|
7 |
F40 |
|
8 |
P0 |
|
9 |
PPS |
|
Rated pressure (MPa) |
-4.0 |
DN10-80 |
1.6 |
DN100-150 |
|
1.0 |
DN200-1000 |
|
0.6 |
DN1100-2000 |
|
0.25 |
DN2200 |
|
Operating Temperature |
E |
<80oC |
H |
<180oC |
|
Grounding ring |
-0 |
No grounding ring |
1 |
There is a grounding ring |
|
Protection level |
0 |
IP65 |
1 |
IP68 |
|
Converter type |
0 |
integrated |
1 |
split-type |
|
communication |
0 |
Nothing |
1 |
RS-485 |
|
2 |
Hart |
|
3 |
PAbus |
|
4 |
FFbus |
|
housing material |
-0 |
carbon steel |
1 |
stainless steel |
|
Body flange |
0 |
carbon steel |
1 |
stainless steel |
|
Install the matching flange |
0 |
without |
1 |
belt |
|
power supply |
0 |
220VAC |
1 |
24VDC |
|
instrument range |
(XXX) |
Example: (2000) represents a large flow rate of 2000M3/h corresponding to 20mA |