Cement slurry level gaugeThe ARLD600 series radar level gauge is used for non-contact continuous measurement of the level of liquids, slurries, and particulate materials. It is suitable for situations with large temperature and pressure changes, inert gases, and evaporation.
The measurement method adopts microwave pulses and can operate normally within the industrial frequency range. The beam energy is low and can be installed in various metal and non-metal containers or pipelines, without causing harm to the human body and the environment.
Cement slurry level gaugeTechnical Specifications:
Basic parameter operating frequency: 6.2G, 10.2G
Beam angle: 24 ° ARLD601, GDLD602
18 ° ARLD603, GDLD604 with DN150 flange
14 ° ARLD603, GDLD604 with DN200 flange
10 ° ARLD603, GDLD604 with DN250 flange
Measurement range: 0... 70m (standard)
Repeatability: ± 3mm
Resolution: 1mm
Sampling: echo sampling 44/55 times/s
Response speed:>0.2s (depending on specific usage)
Output signal: 4... 20mA (two-wire system)
Accuracy:<0.1%
The antenna materials ARLD601 and ARLD602 are PVDF/PTFE
ARLD603 and ARLD604 are 316L stainless steel/C22 Hastelloy alloys
Communication interface: HART communication protocol, PROFIBUS PA (optional)
Process connection G11/2 316L stainless steel, PVDF,PTFE:ARLD601
Flange DN50, DN80, DN100, DN150 (rod antenna): ARLD602
Flanges DN50, DN80, DN100, DN150, DN200, DN250 (horn shaped antenna): ARLD603, ARLD604
Power supply: 24VDC (+/-10%), ripple voltage: 1Vpp
Power consumption: max22.5mA
Environmental temperature conditions: -40 ℃...+80 ℃
Container pressure (gauge pressure): -1... 60bar
Explosion proof certification ExiaII CT6
Shell protection level IP66/IP 68
Two wire system with shared two core wire for power supply and signal output
Cable entry: 2 M20 × 1.5 (cable diameter 5... 9mm)
category |
ARLD601 |
ARLD602 |
ARLD603 |
ARLD604 |
application |
Simple process conditions, corrosive liquids, slurries, and solids for example Water storage tank Slurry storage tank solid particles |
Corrosive liquids, slurries, and solids stored or processed in containers for example Water storage tank Slurry storage tank solid particles |
Adapt to various storage containers or process metering environments, including liquids, slurries, and solids for example Crude oil and light oil storage tanks Slurry storage tank solid particles |
Process containers for large quantities of liquids, slurries, and solids for example Crude oil and light oil storage tanks Slurry storage tank solid particles |
measurement range |
20 meters |
20 meters |
35 meters |
70 meters |
process connection |
thread |
flange |
flange |
flange |
process temperature |
-40-150℃ |
-40-150℃ |
-40-350℃ |
-40-350℃ |
Process pressure |
-1.0-40bar |
-1.0-40bar |
-1.0-60bar |
-1.0-60bar |
precision |
< 0.1% |
< 0.1% |
< 0.1% |
< 0.1% |
resolution |
1mm |
1mm |
1mm |
1mm |
repetitiveness |
±3mm |
±3mm |
±3mm |
±3mm |
frequency range |
6.2G |
6.2G |
10.2G |
10.2G |
Explosion proof protection level |
EXiaIICT6/IP68 |
EXiaIICT6/IP68 |
EXiaIICT6/IP68 |
EXiaIICT6/IP68 |
|
4... 20mA/HART (two-wire) |
4... 20mA/HART (two-wire) |
4... 20mA/HART two-wire) |
4... 20mA/HART (two-wire) |