Do you provide customized processing for the walk-in constant temperature and humidity test chamber? Brand: Nanjing Hilbert Model: HS-100~HS-1500 Material: 304 stainless steel Mirror Panel Temperature range: -70-150 (℃) Humidity range: 30% -98% (RH) Studio size: 400 * 450 * 550 (mm) Power supply: 220/380v Applicable range: hospitals, electronics, military industry,
Step in constant temperature and humidity test chamberStructural characteristics:
This series of wet heat test chambers is suitable for reliability testing of industrial products under constant and alternating wet heat conditions. The performance indicators of the constant temperature box comply with the requirements of GB5170.18 "Basic Parameter Calibration Method for Environmental Testing Equipment of Electrical and Electronic Products".
Suitable for adaptability testing of electrical, electronic, instrumentation, and other products, components, and materials during storage, transportation, and use in high and low temperature alternating humid and hot environments.
The product complies with GB10592.89 and GB2423.22.87 standards. The product adopts an imported temperature controller for temperature and humidity control, which can be programmed to set multiple parameters. The temperature and humidity are directly displayed digitally, and the operation of the constant temperature box is convenient.
Features of the walk-in constant temperature and humidity test chamber:
1. The refrigeration system adopts imported compressors.
2. Electric heating steam humidification method.
3. Saturated gas humidification method.
4. The studio is made of stainless steel, and the outer box is made of cold-rolled steel plate with electrostatic spraying.
5. The outer box is made using CNC machine tools to ensure accuracy and aesthetic appearance.
6. Each system has security protection functions.
|
Main technical parameters:
|
Small (model)
Large (model)
|
HS-50 |
HS-100 |
HS-150 |
HS-225 |
HS-408 |
HS-800 |
HS-010 |
HS-015 |
|
Small studio size (mm)
Large studio size (mm)
|
300×400×450 |
400×450×550 |
500×600×500 |
500×600×750 |
600×800×850 |
800×1000×1000 |
1000×1000×1000 |
1000×1500×1000 |
Thermostatic box, operating mode |
Fixed value operation, program operation |
|
skill
technique
ginseng
number
|
temperature upper limit |
+100℃/+150℃/ 200℃ |
lower temperature limit |
0℃、-10℃、-20℃、-30℃、-40℃、-50℃、-60℃、-70℃、-80℃ |
temperature fluctuation |
±0.5℃ |
Temperature Uniformity |
≤2.0℃ |
temperature deviation |
±2℃ |
humidity range |
20~98%RH |
humidity deviation |
+2/-3%RH |
warm-up time |
35min(20℃~100℃) |
Cooling time |
25min(20℃~0℃)、40min(20℃~-20℃)60min(20℃~-40℃)、90min
(20℃~ -70℃)
|
Temperature and humidity controller |
Imported temperature and humidity controller |
temperature sensor |
Pt100 platinum resistor |
humidity sensor |
Pt100 platinum resistance dry wet bulb |
refrigeration system |
refrigeration unit |
Imported fully enclosed French Taikang compressor unit (environmentally friendly) |
Cooling method |
Single stage compression refrigeration, binary cascade compression refrigeration |
cooling method |
air cooling |
heater |
Nickel chromium alloy electric heater |
Humidification method |
Boiler type evaporation |
humidifier |
Stainless steel heating tube |
Dehumidification method |
Low temperature dehumidification |
circulating fan |
axial flow fan |
Security protection measures |
Overtemperature, overload, overpressure, oil pressure Protection against leakage, water interruption, short circuit, power phase loss, and phase error |
|
material
material
|
housing material |
Cold rolled steel plate electrostatic spraying |
Inner wall material |
SUS304 stainless steel plate |
thermal insulation material |
Ultra fine glass wool |
Standard Configuration |
One test hole of size 50, two sets of test sample shelves, lighting fixtures, and insulated glass observation windows coated with electric heating film |
Optional accessories |
Communication interface, remote monitoring computer and software |
power supply |
380V±10%,50Hz,3P+N+G |
product standard |
GB10586: Technical Conditions for Damp Heat Test Chamber GB10589: Technical Conditions for Low Temperature Test Chamber |
Test Method |
GB/T2423.1、GB/T2423.3、GB/T2423.9、GJB150.4 |
|