- Phone
-
Address
No. 191 Guangzhong West Road, Shanghai
Shanghai Automation Instrument Co., Ltd
No. 191 Guangzhong West Road, Shanghai
0-16MpaStainless steel shock resistant pressure gauge
Precautions for using pressure measuring instruments
(1) The instrument should be installed perpendicular to the horizontal plane; (2) Is the measurement point of the instrument located at the same horizontal position as the instrument installation considering the correction of additional height errors; (3) The distance between the instrument installation site and the measuring point should be as short as possible to avoid slow indication; (4) Ensure sealing and prevent leakage, especially for flammable and explosive gas media as well as toxic and harmful media.
Additional devices should be added to the instrument when used in the following situations, but no additional errors should be generated, otherwise correction should be considered.
(1) In order to ensure that stainless steel pressure gauges are not corroded by the measured medium or affected by high viscosity or crystallization, isolation devices should be installed;
(2) To ensure that the instrument is not affected by rapid changes or pulsating pressure of the measured medium, a buffer is installed. Especially during sudden increases and decreases in pressure, it is easy for pressure instruments to be damaged or scrapped, and even for spring tubes to crack and leak;
(3) In order to ensure that the instrument is not affected by vibration, pressure instruments should be equipped with vibration reduction devices and fixing devices;
(4) In order to ensure that the instrument is not affected by the high temperature of the measured medium, a full bend device should be installed;
(5) Special instruments are strictly prohibited from being used for other purposes, and measurements must not be made without special and reliable devices. It is even more strictly forbidden to use general pressure gauges for pressure measurement of special media;
(6) For newly purchased pressure detection instruments, it is necessary to perform metrological calibration before installation and use to prevent vibration, damage, or other factors affecting the accuracy of the pressure instruments during transportation.
Widely used in industrial sectors such as petroleum, chemical, synthetic fiber, metallurgy, power plants, etc., where high requirements for corrosion resistance and vibration resistance are needed, to measure the pressure of various fluid media.
0-16MpaStainless steel shock resistant pressure gauge
Additional devices should be added to the instrument when used in the following situations, but no additional errors should be generated, otherwise correction should be considered.
1. The current passing through the electric contact pressure gauge should not exceed 3A (ampere), otherwise it will be considered arrogant.
Instruments must be calibrated and calibrated before use. Instruments that are used for a long time should also be regularly calibrated, and their cycle should depend on the degree of use and emphasis. When the instrument is equipped with long-distance transmission and secondary instruments, it should be calibrated and calibrated together with the secondary instruments.
The horizontal section of the connecting conduit should have a certain slope to facilitate the elimination of condensation or gas. When the measured medium is gas, the conduit should tilt low towards the pressure tap direction; When the measured medium is, the conduit should be tilted towards the direction of the pressure measuring instrument; When the measured parameter is a smaller differential pressure value, the inclination can be slightly larger. In addition, if the conduit bends up and down, a condensing device should be installed at the lowest point or an exhaust device should be installed at the highest point according to the medium conditions in the conduit to ensure that the accuracy of the measurement is not affected for a considerable period of time due to the accumulation of condensation or gas in the conduit. Condensation or gas should be discharged regularly.
The requirements for measurement in process production include range and accuracy. In static (or changing) conditions, the maximum value of the measured pressure shall be two-thirds of the full scale value of the pressure gauge; In the case of pulsating (fluctuating) pressure, the maximum value of the measured pressure should be selected as half of the full scale value of the pressure gauge.
7. Stainless steel pressure gauges should be equipped with barrier devices and buffering devices when measuring media with high viscosity and fluctuating pressure.

When adjusting the given value of a pressure gauge, it is necessary to use a slotted screwdriver.
Suitable for observation by staff. Select instruments with varying diameters (external dimensions) based on their location and lighting conditions.
The main feature of Sinumerik 808D is its complexity and ease of use. This product is jointly created by engineers from China and Germany. Siemens has stopped research and development of its existing leading CNC product development platform based on local market demand, and the product cost has been strictly stopped in accordance with German regulations, ensuring high popularity of CNC.
Meanwhile, 2017 also made an appearance at this conference. The concepts of intelligent manufacturing and Industry 4.0 are being highly promoted, corresponding to the release of "Manufacturing 2025" in the middle of last year. In the transition from manufacturing to intelligent manufacturing, the limited business opportunities included in "factories" have already impressed the business community, which is one of the early multinational enterprises to smell the huge business opportunities.
The second-generation SIMATIC HMI panel adopts a 7-inch or 9-inch high brightness 16 million color widescreen display with an aspect ratio of 16:9, which enables highly complex and specific process flows... Siemens SINAMICSG120 series frequency converter SINAMICSG120 is a modular frequency converter that includes various functional units.
We tracked a group of people who moved from the suburbs to the city because there were many construction sites in the suburbs, and the PM2.5 concentration in the air was actually higher than in the city. But after our physical examination, we found that these people's blood pressure, inflammatory factors, coagulation targets, and lung function improved after entering the city.
The Ministry of Environmental Protection believes that with the implementation of the "Ten Measures for Air Quality on Chinese New Year's Eve" and related measures, the overall air quality in 74 cities has improved, and the air quality in the Beijing Tianjin Hebei region has improved significantly. In addition, in the first half of 2014, the monitoring results of key pollution sources showed that the compliance rate of major pollutants from nationally controlled key pollution sources was slightly higher. Three measures, including appointing community and administrative village cadres as food safety information officers, have strengthened the responsibilities of the authorities.