- Phone
-
Address
No. 191 Guangzhong West Road, Shanghai
Shanghai Automation Instrument Co., Ltd
No. 191 Guangzhong West Road, Shanghai
Cable guided wave radar level gaugeGDGW51Shanghai Automation Instrument Co., Ltd
Features: Multiple antennas, anti condensation, anti steam.
Application: Suitable for liquid measurement in environments with volatile substances or vapors (such as coking industry); Adapting to complex process conditions
The environment.
Large distance: 30m
Measurement accuracy: ± 10mm
Process connection: G1 Half A/G2A/1 Half NPT
Detection component material: stainless steel 316L/PTFE
Steel cable/rod diameter: Φ 4mm, Φ 6mm/Φ 10mm
Process temperature: -40... 150 ° C
Process pressure: -1.0... 40bar
Signal output: two-wire system 4... 20mA/HART
Cable guided wave radar level gauge GDGW51Detailed introduction:
GDGW51
License
P standard type (non explosion proof)
I intrinsic safety type (Exia IIC T6)
C Intrinsic Safety Type+Marine License (Exia IIC T6)
G intrinsic safety type+explosion-proof type (Exd [ia] ia IIC T6)
Detecting component type/material
Cable type/stainless steel 316L/PTFE
B-rod/stainless steel 316L/PTFE
C Extended PP/Cable/Stainless Steel 316L
D Extended PP/Rod/Stainless Steel 316L
Extended PTFE/Cable/Stainless Steel 316L
F Extended PTFE/Rod/Stainless Steel 316L
X 特殊定制
process connection
GP thread G1 Half A
KP thread G2A
NP thread 1 half NPT
YP special formulation
Sealing/process temperature
Viton fluororubber/(-30~150) ℃
B Kalrez perfluorinated rubber/(-40~150) ℃
electronic component
B (4-20) mA/HART two-wire system
C (4-20) mA/(22.8-26.4) V DC/HART two-wire/four wire system
D (198-242) V AC/HART four wire system
Shell/protection level (note)
Aluminum/IP67
B Plastic/IP66
D aluminum two chamber/IP67
G stainless steel 316L/IP67
Cable incoming line
M M20x1.5
N ½NPT
On site display/programming
A belt
X without
Cable (rod) length
5-digit number (unit: mm)
Note: The intrinsic safety type (Exia IIC T6) is only compatible with "B" electronic components and "A" type enclosures; The intrinsic safety+marine license (Exia IIC T6) is limited to the use of "B" electronic components and "G" type enclosures; The intrinsic safety+explosion-proof type (Exd [ia] ia IIC T6) is limited to the use of "C" and "D" electronic components and "D" type enclosures; The standard flange size refers to GB/T9119-2000 PN1.6MPa size, with a thickness of 15
The company sells other products:
HSTC0017DIntelligent temperature transmitter,HSTC0017AIntelligent temperature transmitter,HSTR2017ATemperature Transmitter,HSTR2017AIntelligent temperature transmitter,HSTR201717AIntelligent temperature transmitter,Two line wall mounted temperature transmitter HSTRTC9917BG,HSTC001717AIntelligent temperature transmitter,HS1717Passive signal isolator,HSPD171717AIntelligent signal isolator,HSPD1717DIntelligent signal isolator,HSPD1717DIntelligent signal isolator,Intelligent signal isolator LSP171717D