Spot supply of GF dissolved oxygen water quality analysis instrument
GF dissolved oxygen analyzer is divided into GF dissolved oxygen controller and GF dissolved oxygen electrode set for use,
Our company specializes in providing selection and debugging services. In addition, there is long-term inventory available.
characteristic
Optical dissolved oxygen measurement, no flow rate requirement
Durable and sturdy, with a measuring range
Two types of sensor housing materials:
0-20ppm
316L stainless steel or titanium alloy
·Flexible communication interface: 2-channel 4-20mA output, RS485/ModbusRTU
Output, 3-channel relay output
·Flexible installation form
application
·Wastewater treatment: aeration tank, nitrification tank
·Aquaculture: freshwater aquaculture, marine aquaculture
·Surface water monitoring: rivers, lakes, wetlands, etc
·Online monitoring of groundwater, rainwater and other water quality
The iDO 2606 digital fluorescence dissolved oxygen sensor of GF piping system is a
Sensor for dissolved oxygen measurement using optical technology, sturdy and durable, consumable
Low quantity. This product is designed to provide accurate dissolution over a wide measurement range
Dissolve oxygen measurement while reducing maintenance costs.
The sensor provides two types of body materials to be compatible with applications in different media. stainless steel
The material shell is used for freshwater aquaculture, and the titanium alloy material shell is used for seawater aquaculture
Industry.
IDO 2606 dissolved oxygen sensor is a digital sensor that directly provides RS485/
The output of Modbus RTU can be used with a header or independently.
The sensor has built-in temperature compensation and can output both dissolved oxygen and temperature.
Technical Specification for iDO 2606 Digital Fluorescence Dissolved Oxygen Sensor
Parameter technical specifications
Measurement parameter dissolved oxygen
Basic principle: Fluorescence quenching principle
technical parameters
Range dissolved oxygen: 0~20 mg/L or 0~200% saturation
Temperature: 0~45 ° C
Precision dissolved oxygen: measurement value ± 3% or ± 0.3mg/L, whichever is greater;
Temperature: ± 0.5 ° C
Repetitive dissolved oxygen: 0.3 mg/L
Temperature: 0.2 ° C
Continuous measurement interval
Material: 316L stainless steel (optional titanium)
Dimensions: Φ 38 x 240 mm (sensor body)
Protection level IP68
Output serial port output RS485, Modbus RTU protocol
Installation requirements
Installation method: Submerged
Install thread G1 on the upper thread
Power supply voltage: 12-24VDC
Cable length 10 meters
Pressure range<0.3MPa
Sample temperature 0~45 ° C
Environmental temperature -20 ° C~50 ° C
Storage temperature -40 ° C~70 ° C
Humidity<95% (uncondensed)
Technical specifications for EcoPro 7900-1 digital fluorescence dissolved oxygen analyzer transmitter
Parameter technical specifications
Measurement parameter dissolved oxygen
technical parameters
Range dissolved oxygen: 0~20 mg/L
Temperature: 0~45 ° C
Precision dissolved oxygen: measurement value ± 3% or ± 0.3mg/L, whichever is greater;
Temperature: ± 0.5 ° C
Repetitive dissolved oxygen: 0.3 mg/L
Temperature: 0.2 ° C
Display resolution dissolved oxygen: 0.01mg/L
Temperature: 0 1°C
Continuous measurement interval
Shell&Display
Display screen 240 * 160 dot matrix LCD screen
Material: PC plastic (polycarbonate)
Hole size 138mm * 138mm
Dimensions: Height: 144mm, Width: 144mm, Thickness: 104mm
Header protection level IP65
Software features
Function password management function password: set 3700, calibrate 3900, historical data 1300, historical curve 1400
Historical data is available, with a storage interval of 5 minutes
Language: Chinese/English
output
Serial port output 1 RS485, Modbus RTU protocol
Current output 2-channel 4-20mA output, dissolved oxygen/temperature
Relay output with 3 normally open contacts,
Data Logger with data recording, can store 1000 pieces of data, historical data can be exported
Installation requirements
Installation location indoor
Power supply voltage 100-240VAC, 50/60Hz
Sample temperature 0-45 ° C
Environmental temperature -20 ° C~50 ° C
Storage temperature -40 ° C~70 ° C
Humidity<95% (uncondensed)
Spot supply of GF dissolved oxygen water quality analysis instrument
Order code Chinese description English description Basic parameters
300 149 701 digital fluorescence dissolved oxygen analyzer ppm DO transmitter header EcoPro 7900-1 type 220VAC
300 149 711 digital fluorescence method dissolved oxygen sensor SS ppm DO sensor SS sensor iDO 2606 type 0-20ppm, 10m cable, 316L stainless steel material
300 149 751 Digital Fluorescence Dissolved Oxygen Sensor Ti ppm DO Sensor Ti Sensor iDO 2606 Type 0-20ppm, 10m Cable, Titanium Alloy Material
Order code Chinese description English description Recommended for normal use Replacement cycle
300 149 761 ppm dissolved oxygen membrane head ppm DO membrane cap 12 months

Georg Fischer (GF) was founded in 1802 and headquartered in Switzerland
Schaffhausen, And it is listed on the SWX Swiss Exchange. as
GF, an operating industrial group, is committed to becoming a sustainable water and fluid solutions provider
In the field. GF Group focuses on four core areas: GF Piping Systems
GF Building Flow Solutions、GF Casting Solutions 和 GF Machining
Solutions。