+GF+Signet integrated rotary flow meter in large stock
The 2537 rotary flowmeter series features low flow rate, low power, and high resolution, with various output options such as volume pulse
Pulse frequency divider, flow switch, digital (S3L) or 4-20 mA. It can be directly accessed through the built-in user interface
Set up the unit on site.
The 4-20 mA model provides blind current loop output.
The digital (S3L) model provides digital (S3L) output for connecting Signet 8900 multi parameter control
Device or 9900 transmitter.
The composite model uses a single relay (mechanical or solid-state) and has three optional operating modes:
The frequency divider mode can reduce the wheel frequency to adapt to devices with low-frequency inputs.
The accumulation mode can achieve one pulse output for each group of traffic.
The flow switch mode uses a single relay and can perform high or low alarm operations.
A small LCD can be set up on the 2537 without using any external devices. During normal operation period
The display is not visible.
Planting liquids and chemicals.
All plastic materials (including typical pipe types such as PVC, PVDF, PP, etc.)
PE) is more or less permeable to the medium it contains, such as water or volatile compounds
Quality, including some acidity. This effect is not related to porosity, but purely gas permeability
The problem of plastic diffusion.
If the plastic material is compatible with the medium, penetration will not damage the plastic itself. but
Yes, if the plastic contains other sensitive components such as GF Signet plastic wheel conveyors
Sensors may be affected by the diffusion of media into the body and rotor
Or damaged.
There have been reports of PVDF wheel sensors malfunctioning in hot nitric acid applications.
PVDF allows nitric acid components to penetrate without damaging itself. There's no clear here
Accurate guidelines, as the destructive effect on sensors largely depends on
Temperature, pressure, and medium concentration.
It is possible to apply sensors in corrosive media. GF Signet can
Provide sensors with special requirements, whose different internal resin encapsulation can delay acid
The destructive effect on sensors.
Wheel maintenance:
The wheel on the sensor is prone to wear and may require repair and replacement of components (wheel,
Rotating shaft, O-ring, bearing, cage, etc. The maintenance cycle depends on the application environment
It depends on the environment, medium characteristics, and installation. Including but not limited to: process flow rate, water hammer
The appearance of corrosive and abrasive fluids, as well as the surrounding equipment where sensors are installed.
GF Signet provides separate replacement parts and wheel replacement kits, including replacement operations
Provide an instruction manual that allows customers to perform on-site replacement to reduce system downtime.
+GF+Signet integrated rotary flow meter in large stock
Product Specifications
General Specifications
Flow velocity range ..........................0.1 m/s - 6 m/s
Pipe diameter range .........................DN15 - DN200 (½ in. - 8 in.)
Minimum Reynolds number .....................4500
Wiring port 1/2 inch NPT thread; Liquid tight joint can be connected
Receiving electricity with an outer diameter of 7mm-10mm
缆 (0.275in.-0.394in.)
material
shell ........................................PBT, yellow
Inner shell .......................................Valox, black
Liquid receiving material
-P0, -P1
Sensor body Fiberglass filled polypropylene
O-ring ..............................FKM
Rotating shaft Titanium
Wheel ..................................PVDF, Black; Optional ETFE, with or
Without carbon fiber reinforced PTFE shaft sleeve
-T0
Sensor body ....................PVDF, natural color
O-ring ..............................FKM
Rotating shaft .................................PVDF, natural color
Wheel ..................................PVDF, natural color; Optional ETFE, with
Or without carbon fiber reinforced PTFE shaft sleeve
performance
Input frequency range .........................1 - 1000 Hz
System response The nominal refresh rate is 100ms
Wheel frequency Nominal 49Hz per m/s
Linearity ± 1% of the measuring range
@ 25 °C (77 °F)
Repetitive accuracy ± 0.5% of the measuring range
@ 25 °C (77 °F)
electricity
Relay specifications
Dry contact SPDT...... 5 A @ 30 VDC, 5 A @ 250 VAC
Solid state relay ...........................100 mA @ 40 VDC,
70 mA @ 33 VAC
Power requirements
Complies with:
Equipped with dry contact relay ...... Nominal 24VDC ± 10%, stabilized voltage,
Current 30mA
Equipped with solid-state relays ...... Nominal 5-24VDC ± 10%, stabilized voltage,
Current 30mA
Number (S3L).................................. 5.0-6.5VDC, current 30mA
Nominal 1.5mA)
4-20 mA............................. Ripple voltage 400mV
Current 30mA
Reverse polarity and short circuit protection ...... Up to 40V, 1 hour
Overvoltage protection 40 VDC for more than 1 hour
output
Signal damping Can be set from 0 to 100 seconds
Sensitivity response Can be set to 0-9 degrees
Pulse divider/total pulse output
Pulse divider setting ................. 1.0000 - 99999
Pulse rate ...................... 300 Hz
Pulse width ................. 50 ms
Flow switch output
Relay mode Low, high
Delay .................................. 0.0-6400.0 seconds
Delay Adjustable

wiring
Only qualified personnel are allowed to operate the electrical connections of this product.
To use wiring terminals:
1. Rotate the yellow lid counterclockwise by ¼ circle to remove it.
2. Remove the two fixing screws and then remove the black cover plate.
Before connecting the cables to the terminals, please thread all cables through the conduit ports.
The terminal block is suitable for wires with 16-22AWG specifications.
The cable diameter must be 7 mm to 10 mm (0.275 in. to 0.394 in.) to ensure proper sealing in the liquid tight joint.
3. The conduit port has a 1/2-inch NPT thread. After wiring, seal the port with a liquid tight conduit connector (3-9000.392-1) or conduit.
For the installation of conduit:
The threaded conduit has a half inch NPT thread, which can be directly connected to the conduit port.
For conduit with ISO threads, please use the black thread adapter included with the connector kit.
To comply with NEC requirements, do not use any metal conduit during installation.
Manufacturer Part Number Order Code Description
2537 system for 0.5-4-inch pipelines:
Polypropylene body, black PVDF wheel, titanium shaft, FPM O-ring
159 001 291 pulse/flow switch, DCR,-P0, Integrated installation
159 001 292
159 001 295
3-2537-1C-P0
3-2537-2C-P0
3-2537-5C-P0
3-2537-6C-P0 159 001 296
Pulse/flow switch, SSR,-P0, Integrated installation
Digital (S3L), integrated installation
4 - 20 mA, Integrated installation
2537 system for 5-8-inch pipelines:
Polypropylene body, black PVDF wheel, titanium shaft, FPM O-ring
159 001 303 pulse/flow switch, DCR,-P1, Integrated installation
159 001 304
159 001 307
3-2537-1C-P1
3-2537-2C-P1
3-2537-5C-P1
3-2537-6C-P1 159 001 308
Pulse/flow switch, SSR,-P1, Integrated installation
Install digital S3L, integrated
4 to 20 mA, Integrated installation
2537 system for 0.5-4-inch pipelines:
Natural color PVDF body, natural color PVDF wheel and shaft, FPM O-ring
159 001 315 pulse/flow switch, DCR,-P0, Integrated installation
159 001 316
159 001 319
3-2537-1C-T0
3-2537-2C-T0
3-2537-5C-T0
3-2537-6C-T0 159 001 320
Pulse/flow switch, SSR,-P0, Integrated installation
Digital (S3L), integrated installation
4 - 20 mA, Integrated installation
Attachment
Manufacturer Part Number Order Code
3-2536.320-1 198 820 052
3-2536.320-2 159 000 272
3-2536.320-3 159 000 273
3-2536.321 198 820 054
3-2536.322-1 198 820 056
3-2536.322-2 198 820 057
3-2536.322-3 198 820 058
M1546-1 198 801 182
M1546-2 198 801 183
M1546-3 198 820 014
M1546-4 198 820 015
P51545 198 820 016
1220-0021 198 801 000
1224-0021 198 820 006
1228-0021 198 820 007
P31536 198 840 201
3-8050.390-1 159 001 702
3-8050.390-3 159 310 116
3-8050.390-4 159 310 117
3-9000.392-1 159 000 839
3-9000.392-2 159 000 841
7310-1024 159 873 004