- Phone
-
Address
1201, Building 80, No. 88 Chundu Road, Minhang District, Shanghai
Shanghai Lianqiao Biotechnology Co., Ltd
1201, Building 80, No. 88 Chundu Road, Minhang District, Shanghai
JSKX05-4393Spot quotation for consumables for the Jian Shuo ON-5ms gas chromatography column
TVOCAnalysis column execution standardGB 50325-2001AppendixETotal Volatile Organic Compounds in Indoor Air(TVOC)The determination
Application scope: Indoor airTVOCanalyze
Temperature range:60to240℃
Application conditions: Program temperature rise50~250℃, the initial temperature is50℃, maintain10minHeating rate5℃/min,to250℃, maintain2min.
productspecification:
specification purpose material )
30m×0.32mm×1.0MTVOCQuartz glass
30m×0.25mm×1.0MTVOCQuartz glass
30m×0.53mm×1.0MTVOCQuartz glass
50m×0.32mm×1.0MTVOCQuartz glass
50m×0.25mm×1.0MTVOCQuartz glass
50m×0.53mm×1.0MTVOCquartz glass
JSKX05-4393Spot quotation for consumables for the Jian Shuo ON-5ms gas chromatography column
In addition, our company also has the following different types of gas chromatography columns
1. JS-1TheJS-101TheJS-30
*Methyl polysiloxane stationary phase; Non-polar column; Bonded cross-linked column; Applied to hydrocarbons, pesticides, phenols, sulfides, seasonings, and spices, etc
2. JS-52
5%phenyl95%Methyl polysiloxane stationary phase; Weak polarity column; Bonded cross-linked column; Applied to hydrocarbons, aromatic hydrocarbons, pesticides, herbicides, amines, phenols, etc
3. JS-54
1%vinyl4%phenyl95%Methyl polysiloxane stationary phase; Weak polarity column; Bonded cross-linked column; Applied to hydrocarbons, aromatic hydrocarbons, pesticides, herbicides, amines, phenols, etc
1-3For non-polar and weakly polar chromatography columns, please refer to the table above for the quotation
4. PEG-20M
polyethylene glycol20MFixed phase; Polarity column; Applied to alcohols, aromatic compounds, solvents, essence, etc
5. FFAP
Modified polyethylene glycol stationary phase; Polarity column; Applied to alcohols, ketones, organic acids, fatty acid methyl esters, etc
6. JS-1701
14%Cyanopropyl86%Methyl polysiloxane stationary phase; Bonded cross-linked column; Medium polarity column; Applied to alcohols, ketones, pesticides, herbicides, environmental samples, etc
7. JS-1301
6%Cyanopropyl94%Methyl polysiloxane stationary phase; Bonded cross-linked column; Medium polarity column; Applied to solvent residues, environmental volatile organic compounds, etc
8. JS-17
50%phenyl50%Methyl polysiloxane stationary phase; Bonded cross-linked column; Medium polarity column; Applied to alkaloids, pesticides, herbicides, etc
9. JS-13
5%phenyl1%vinyl94%Methyl polysiloxane stationary phase; Bonded cross-linked column; Weak polarity column; Applied to hydrocarbons, pesticides, herbicides, insecticides, etc
10. JS-275
10%Trifluoropropyl90%Methyl polysiloxane stationary phase; Bonded cross-linked column; Polarity column; Applied to polar compounds
11. PLOTMao Xizhu
PLOT Q/S/UMainly used for the analysis of low boiling point substances such as low-carbon hydrocarbons, water, alcohols, ketones, esters, etc., especially suitable for the analysis and detection of aqueous samples.PLOT AL2O3Mainly used forC1-C6The analysis of hydrocarbons can achieve baseline separation of all isomers in a very short period of time.PLOT 5AMainly used forH2TheHeTheO2TheN2TheCOTheCH4Waiting for the detection of inorganic gases.PLOT CarbonsieveMainly used for detection*Gas, low-carbon hydrocarbonsCO2Wait.