Specific surface area and pore size analyzerAdopting an integrated design, that is, the degassing module is integrated into the instrument host, reducing a lot of space for the laboratory; At the same time, its degassing module and analysis module are independent of each other, with independent gas path system, detection system, and vacuum system, which can operate simultaneously without affecting each other, improving the detection speed of quality control analysis; Each analysis port is equipped with an independent pressure sensor to ensure data consistency and stability; An independent saturation vapor pressure detection system monitors the saturation pressure in real-time during the analysis process to ensure the accuracy of the data.
Specific surface area and pore size analyzer
Having one sample analysis port and one degassing port, it can simultaneously analyze one P0 test position (the sample analysis station can be 1, 2, 3, 4, 6, 8. The degassing position can be 2, 4).
The degassing and analysis positions are designed in an integrated manner, and have independent vacuum and gas circuit systems.
Uneven and vulnerable soft heating package, composite material heating furnace with linearly adjustable heating rate, high temperature control accuracy, and anti scald design.
Each analysis port is equipped with an independent inlet pressure sensor, ensuring high data consistency.
Introduce dead volume dynamic calibration technology to address the impact of liquid nitrogen volatilization on volume quantification.
The pneumatic control system applies vacuum pumping dynamic speed regulation technology (I-PID).
Optional embedded isothermal jacket for gas isothermal adsorption testing from 0 ℃ to 60 ℃.
Main parameters:
1. Analysis method: Static capacity method
2. Test data: Specific surface area ≥ 0.0001m2/g, pore size analysis 0.35nm-550nm
3. Analysis accuracy: repeatability ± 1% (for samples ≤ 1m2/g: ± 1.5%)
4. Analysis station: 1 sample analysis port, 1 P0 real-time testing position
5. Dewar flask: 3.5L large capacity Dewar flask (can be configured with 4L)
6. Adsorbed gases: nitrogen, hydrogen, krypton, carbon monoxide, carbon dioxide, methane, etc
7. Sample degassing station: It has one single station sample preparation station with independent temperature control system and vacuum system. The upper temperature limit is 400 ℃, and it is equipped with an independent mechanical pump. The degassing station can work simultaneously with the analysis station. The degassing time and temperature can be set and changed on the host interface
8. Temperature analysis: In addition to commonly used low-temperature nitrogen adsorption, an isothermal jacket can also be selected for gas isothermal adsorption testing from 0 ℃ to 60 ℃.
9. Hardware system control:
Pressure detection system: The analysis port is equipped with an independent inlet pressure sensor, and the software can view the pressure values at various positions in real time. The saturated vapor pressure test position is equipped with an independent pressure sensor to collect the saturated vapor pressure in real time
Gas path control system: application of vacuum pumping dynamic speed regulation technology (I-PID) and containerized gas path
Voltage division range: possessing independent P0Analysis port, P/P0 4 × 10-7-0.995, Po analysis port is equipped with an independent pressure sensor to ensure real-time data collection of saturated vapor pressure
Vacuum system: equipped with a two-stage rotary vane mechanical pump, with a maximum vacuum of 4 × 10-2Pa
Liquid level control system: Temperature difference dynamic calibration technology compensates for the positioning error of traditional liquid level sensor technology, and can be used for coolant at different temperatures to maintain the minimum dead volume of the system
Data acquisition system: high-precision 24 bit analog-to-digital conversion system, with data storage function for instrument accidental power failure
10. Data processing: BET specific surface area/adsorption and desorption isotherms/BJH pore volume analysis/pore area analysis/total pore volume/total pore area/Langmuir method surface area analysis/T-plot inner and outer surface area and micropore volume/DR micropore area and micropore volume/HK micropore distribution/MP micropore distribution, etc
11. Other: Host length 550mm, width 550mm, height 850mm; power 800W; working voltage 220V