Product Introduction
To ensure national energy security, achieve the goal of accelerating the digital transformation of detection and monitoring technology, and building a solid foundation for high-quality detection and monitoring data, and ensure the independent and controllable core technology, it is urgent to improve the level of autonomy of digital detection and monitoring equipment. In the fields of environmental governance, mining, geological exploration, nuclear energy development, chemical manufacturing, and research and development of new materials in China, there are higher requirements for the accuracy, timeliness, and intelligence of detection and monitoring technology.
FASP-FG Fully Automatic Sample Preparation InstrumentIntegrating functions such as sample recognition, precision grinding, screening, weighing, sample loading, and cleaning, it can start the full process automation with one click to complete the preparation of hard samples and the cleaning of equipment sample components, eliminating the tedious process of manual or mechanical assisted sample preparation. The advantages are significant, greatly improving the quality and efficiency of sample preparation, freeing operators from repetitive and heavy labor, avoiding dust damage, and focusing on more valuable experimental analysis links.
Product Features
High throughput:The equipment is equipped with a 28 bit automatic sampling device, which can meet the workload of sample preparation throughout the day. It can automatically inject and output samples without manual intervention.
Zero residue:Configure a water washing module to clean the grinding tank and grinding equipment with water washing and fast hot air drying.
High efficiency:Multi task collaboration of robotic arms, with an average preparation time of 10-15 minutes for a single sample.
fully automatic:The entire process only requires manual placement of the sample to be prepared, setting of parameters, one click start, and collection of the final finished sample.
Pollution prevention:Each sample uses one sample bottle throughout the entire process, without the need for transportation. After preparation, it is fully automatically cleaned to avoid cross contamination; The entire process does not come into contact with the metal elements to be tested, avoiding external contamination.
Low temperature:Intermittent grinding to prevent sample testing results from being affected by high temperatures.
Traceability:Strictly implement relevant preparation standards and specifications to ensure that the prepared samples are representative, automatically record various data, and have traceability throughout the entire process.
Mainly based on standards
DZ/T 0130.4-2006 Quality Management Specification for Geological and Mineral Laboratory Testing
HJ/T 166-2004 Technical Specification for Soil Environmental Monitoring
General Provisions for Soil Sample Collection and Preparation in Environmental Nuclear Radiation Monitoring (EJ428-89)
GB/T 14505-2010 General Principles and Regulations for Chemical Analysis of Rocks and Ores
HJ/T 20-1998 Technical Specification for Sampling and Preparation of Industrial Solid Waste
JC/T 2664-2022 Chinese ISO Standard for Testing Sand Particle Size
Main technical parameters
Injection module |
28 250ml sample bottle positions or 50 100ml sample bottle positions. |
Operation Module |
Embedded intelligent operation control system, touch screen display. |
Grinding module |
Four grinding positions, the grinding module is made of zirconia material (optional materials include tungsten carbide, agate, corundum, high manganese steel (without water washing), etc.). The contact part between the grinding module and the sample does not contain any metal elements to be tested, and it can operate at high speed and grind efficiently. |
|
Screening module (Optional) |
The sample is automatically sieved through sieve sizes of 100 mesh/200 mesh and other specifications, with standard measurable sieve sizes. |
Weighing module |
Built in weighing module; It can automatically weigh and record the weight of each step of the sample in the system. |
|
Cleaning Module (Optional) |
The grinding module adopts high-pressure water washing combined with hot air blowing for drying, and the clean wastewater is discharged through a filtering device, which is green and pollution-free; The whole machine is fully automatic cleaned, and the screening module is cleaned with a brush combined with air blowing. The negative pressure device absorbs dust to ensure that the sample is clean and free of residue. |
application field
Geological and Mineral Resources
Smart Mine
Petroleum and petrochemical
agriculture and rural areas
Land and Resources
ecological environment
Third party testing agency