Soil and Fertilizer Testing Training Room

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Soil and Fertilizer Testing Training Room Training Program: Determination of Soil Texture, Determination of Soil Bulk Density and Porosity, Determination of Soil pH, Determination of Soil Moisture Content, Determination of Soil Field Capacity, Qualitative Identification of Chemical Fertilizers, Determination of Soil Nutrients, Determination of Nutritious Soil and Hydroponic Solutions, Soil Testing Formula Fertilization Technology, Trace Elements, Heavy Metal Elements, etc.. Teaching objective: By analyzing the nutrients and harmful elements in soil and fertilizers, we can obtain information on soil nutrient status, soil pollution status, fertilizer indicators, etc., and provide scientific guidance for fertilization and soil environmental remediation.

Product Details


Soil and Fertilizer Testing Training RoomPractical Training ProjectDetermination of soil texture, soil bulk density and porosity, soil acidity and alkalinity, soil moisture content, soil field capacity, qualitative identification of chemical fertilizers, determination of soil nutrients, determination of nutrient soils and hydroponic solutions, soil testing and fertilization techniques, trace elements, heavy metal elements, etc..
Soil and Fertilizer Testing Training Roomteaching objectivesBy analyzing the nutrients and harmful elements in soil and fertilizers, it is possible to obtain information on soil nutrient status, soil pollution status, fertilizer indicators, etc., and provide scientific guidance for fertilization and soil environmental remediation.

serial number

project

Equipment name/expenditure item

Overview of Model Specifications/Expenditure Purpose

unit

quantity

1


High precision soil quality detector

1The host of this instrument comes with a one-year warranty and lifetime maintenance.
2
This instrument can detect simultaneously12A sample; Measure a soil sample(NThePTheK)≤28Detect three soil samples simultaneously in minutes(NThePTheK)≤35minute
3
This instrument has a built-in thermal printer that can print data.PS:Trace element and heavy metal testing items can be printed.
4
Power supply for this instrument: AC:180V~240V、50Hertz; Direct current:7V~9V(Built in lithium battery).
5
Range and resolution of this instrument:0.001-9999.
6
Stability of this instrument: Drift less than one hour0.3%.
7
The wavelength of this instrument is red light680nmBlue light420nmGreen light510nmOrange light590nm.
8
Error of this instrument: Soil ≤5%

platform

1

2

Soil moisture analyzer

Moisture content measurement range:0.01%-100%Accuracy:0.005gSensor: GermanyHBM;30-200℃;

platform

1

3

pH meter

Instrument level: 0.01 Grade;pH:(-2.00~18.00)pHElectronic unit indication error: ±0.01pH;mV: (-1999~1999)mV; Supporting measurement range:(0.00~14.00)pH

platform

1

4

Soil pollutant detector

Technical parameter requirements:
2.1
Detecting elements:
K,Ca,Ti,V,Cr,Mn,Fe,Co,Ni,Cu,Zn,As,Se,Rb,Sr,Y,Zr,Nb,Mo,Ag,Cd,Sn,Sb,W,Re,Pd,Au,Hg,Pb,Bi,Cs,Ba,Th,U
wait34Multiple elements or more, and displayed simultaneously on the instrument screen34Elements and their contents.
2.2
It can store and display the types, contents, and testing times of heavy metals. Storing data and graphs exceeding100000One.
2.3
Data transmission and processing: BluetoothUSBData cable, can also be connected externally for tablet computers and mobile phonesAPPThe software connects to the instrument for easy and convenient operation and use.
▲2.4Security system: The front end of the device is equipped with dual detectors for infrared and visible light, hardware protection, and non software sensingXAfter the light is turned off, it will automatically close when there are no samples in the testing windowXRadiation, without the need for an external radiation shield, has the functions of heat dissipation and radiation leakage prevention, ensuring safe use (providing high-definition image proof and stamped with the manufacturer's seal, no negative deviation treatment is provided).
2.5
Radiation protection: does not contain radioactive isotope excitation sources, with strong environmental performance;XRadiation dose ≤0.06
MSV/h.
2.6
No need for sample pre-treatment, non-destructive analysis is performed, and quick analysis is carried out in a short time, with direct on-site analysis and determination.
2.7
display:
2.7.1
Screen size:4.0-4.8Inch, high brightness color resistive screen, can also be operated in the wild with gloves, does not require direct embeddingPDAThe human-computer interaction method with mobile phones.
▲2.7.2The screen and host are designed with an integrated fixed angle, and the display screen cannot rotate freely. The screen has a longer service life, is less likely to be damaged, and is more suitable for on-site applications (high-definition pictures are provided as proof and stamped with the manufacturer's official seal, and negative deviation treatment is not provided).
▲2.8Operating system: Chinese operating interface, dedicated analytical levelAndroidEmbedded real-time operating system, nonWindowsOperating system, faster running speed, no virus intrusion risks, ensuring data security (providing high-definition image proof and stamped with the manufacturer's seal, no negative deviation processing provided).
2.9
Working conditions:
2.9.1
Source of Excitation: High Performance MicroXRadiation tube, standard silver target, maximum voltage ≥50kV.
2.9.2
detector:High performance detector, energy resolution ≤145ev.
2.9.3
Operating Temperature-20℃~+50℃。
2.9.4
Working humidity: Relative humidity<95%.
2.9.5
The instrument has an automatic average calculation function, which facilitates customers to calculate the average value on site.
2.9.6
The instrument has sound and light prompts, with obvious light prompts during operation.
2.9.7
Signal acquisition and processing: Optical path design, built-in air pressure sensor, automatically adjusts air pressure factor according to altitude, and improves the excitation effect of light elements compared to others40%Compared to rare earth elements, the excitation effect of rare earth elements is improved30%.
▲2.9.8Heat dissipation: In addition to the front-end heat dissipation head, the instrument comes with a dedicated aluminum alloy for heat dissipationTThe slotted heat dissipation device improves the heat dissipation performance of the instrument, eliminating the need for frequent waiting for the detector to cool down and increasing efficiency (providing high-definition image proof and stamped with the manufacturer's seal, no negative deviation treatment is provided).
2.10
Indicator requirements:
2.10.1
Measurement time: ≤30s.
2.10.2
Detection limit:ppmLevel.
2.10.3
The battery can work continuously on a single charge8More than hours.
▲2.10.4The battery has a remaining power display function, making it convenient to check the battery level on site at any time; Without inserting the battery into the device, the battery level can be directly checked on the battery, and inserting the device can also directly check the battery level on the battery (providing high-definition image proof and stamped with the manufacturer's seal, no negative deviation treatment is provided).
2.10.5
External standard plate for the instrument, no calibration required upon startup.
2.10.6
The instrument can establish targeted calibration curves.
2.10.7
Fully integrated Chinese software,Easy to operate.
2.11
weight:≤1.6 Kg.
▲2.12Diversified analysis modes: It has multiple modes such as soil, industrial land, agricultural land, commercial land, residential land, etc. It can quickly determine whether the sample meets the standards based on element results and built-in environmental quality standards (customizable). When the test results of a certain element in the sample exceed the built-in standards, the software will issue a warning prompt (providing high-definition image proof and stamped with the manufacturer's official seal, not providing negative deviation treatment).

platform

1

5

Soil testing formula fertilizer applicator

1The host of this instrument comes with a five-year warranty and lifetime maintenance.
2
This instrument can detect simultaneously12A sample; Measure a soil sample(NThePTheK)≤13Detect twelve soil samples simultaneously in minutes(NThePTheK)≤49minute; Test a soil sample (single trace element) ≤28Minute, simultaneously detect twelve soil samples (single trace element) ≤59minute
3
This instrument has a built-in thermal printer that can print information such as test date, test time, test items, crop type, crop yield, and fertilizer application amount.
4
Power supply for this instrument: AC:180V~240V、50Hertz; Direct current:7V~9V(Built in lithium battery).
5
The wavelength of this instrument is red light680nmBlue light420nmGreen light510nmOrange light590nm.
6
The instrument does not require blank and standard settings, and the sample can be read directly.
7
The instrument displays Chinese characters with backlight, automatically stores detection results, and can store over a thousand pieces of data.
8
The instrument is equipped with a crop expert fertilization system, which scientifically recommends fertilizer ratios for crops based on soil sample analysis results.

platform

1

6

Fertilizer component detector

1The host of this instrument comes with a one-year warranty and lifetime maintenance.
2
This instrument tests a fertilizer sample(NThePTheK)≤48Minute, simultaneously testing three fertilizer samples(NThePTheK)≤85minute
3
Repetitive error: not exceeding 0.3%.
4
Power supply for this instrument: AC:180V~240V、50Hertz; Direct current:7V~9V(Built in lithium battery).
5
Range and resolution of this instrument:0.001-9999.
6
Stability of this instrument: Drift less than three minutes0.2%.
7
The wavelength of this instrument is red light680nmBlue light420nmGreen light510nmOrange light590nm.

platform

1

7

pH meter

Instrument level: 0.01 Grade;pH:(-2.00~18.00)pHElectronic unit indication error: ±0.01pH;mV: (-1999~1999)mV; Supporting measurement range:(0.00~14.00)pH

platform

5

8

Pre-processing equipment

analytical balance

0.1mg,0.01g,1mg

set

5

9

electric hot plate

Heating size:300*200Load bearing capacity:5kgRated temperature:420℃

platform

1

10

Electric hot blast drying oven

Inner container size:350*350*350Temperature control range: room temperature+10℃-250℃; With air blowing; stainless steel inner pot

platform

1

11

Basic equipment

workbench

Steel wood, high800mm, 定制

linear meter

40

12

fume hood

Product dimensions:1200×750×1950mmExhaust speed:0.3-0.6m/s;

a

2