The laboratory small deoxygenation machine uses ordinary tap water as the water source, with a dissolved oxygen content of 1ppm in the effluent and a resistivity of>10.0M Ω• cm. It is specialized for medical diagnostic equipment inlet water, and specific water machine configurations are made according to different brands and models of biochemical analyzers to meet the needs of biochemical analyzers, providing hospitals with fully automatic and high-quality pure water solutions for inspection and diagnostic equipment. Free on-site installation and debugging of the pure water machine, and comprehensive after-sales service provide you with intimate, economical, and reliable medical biochemical pure water machine equipment.
Product Details

Small laboratory deoxygenation machineTechnical Parameters

1. Inlet water source: urban tap water (total dissolved solids TDS<200ppm), water pressure 1-5kg/cm2, water temperature 5-45 ℃;
2. Water production capacity: 20/40/60/80/100/150 liters/hour;
3. Biochemical water: conductivity ≤ μ s/cm (online monitoring), micro particles<1/ml;
4. Host size: 20~40 liter model 1050X430X520mm; 60-100 liter models 1350 × 500 × 740mm; 150 liter models 1480 × 600 × 600mm;
5. Weight: 20-40 liter models<50kg, 60-100 liter models<100kg, 150 liter models<150kg;
6. Power: 20-40L model 150W, 60-100L model 150-300W, 150L model<2kW
7. Pure water tank configuration: 20-40 liter models are equipped with a 40 liter pure water tank, 60-100 liter models are equipped with a 100 liter pure water tank, and 150 liter models are equipped with a 200 liter pure water tank.
Small laboratory deoxygenation machineProduct Features
1. Type II and III are suitable for clinical immunology and enzyme-linked immunosorbent assay experiments; Type I is suitable for clinical biochemical analyzer diagnostic experiments;
2. Fully automatic functions such as automatic flushing of the system;
3. Microcomputer fully automatic control, with system startup self-test, automatic protection for water shortage and power outage, automatic protection for water and electricity overpressure, and automatic stop/start of water tank high water level;
4. Integrated process design, stable performance, and simpler equipment installation and maintenance;
5. The system adopts high-quality components such as imported pure water pumps, imported RO membranes, and imported pipe fittings, and adopts modular and integrated process design for stable performance and simpler equipment installation and maintenance;
6. Compared with other general-purpose water quality pre filters, water quality pre processors can significantly improve the service life of consumables and reduce their operating costs;
7. Water for inspection and analysis, reagent preparation, laboratory testing, microbial cultivation, container cleaning, etc;
8. The front of the host is equipped with a pure water intake port, which is controlled by PLC touch keys, making it convenient for users to meet other water needs;
9. According to the pressure, water quality, and inlet method requirements of different biochemical analyzers, different water tank and pipeline configurations are made. Engineers install them on site and provide on-site training guidance to provide you with comprehensive services.
The pure water machine provides you with a laboratory pure water equipment experience that exceeds your value for money.

NT-DI-CN Laboratory Small Pure Water Deoxygenation System

Model number

NT-DI-CNA 型

NT-DI-CNB 型

Total dissolved oxygen content

≤1mg

≤10ppb

Water quality of water production

DI water: resistivity ≥ 1M Ω .cm@25 ℃ (real-time online display during water production), microorganisms<1cfu>0.22 µ m<1/mL comply with GB/T 6682-2008 laboratory second water standard

UP water: resistivity 18.25M Ω .cm@25 ℃ (real-time online display during production and water intake), TOC/total organic carbon<10pppb, heavy metals<0.1ppb, microorganisms<1cfu/mL, heat source<0.001EU/mL

Particles (>0.22 µ m)<1/mL, soluble silicon (SiO2)<1 ppb, absorbance (254nm, 1cm)<0.001 AU, evaporation residue (105 ± 2 ℃), mg/L≤0.5、 Metal cation content (ppb): Fe<0.005, Cu<0.005, Al<0.005, Ni<0.005, Zn<0.02, Cr<0.005, Na<0.01, K<0.02, anion content (ppb): Cl -<0.01, NO2-<0.02, NO3-<0.02, SO42-<0.01. The water quality is superior to the Class I water standards of China National Laboratory GB6682-2008, American ASTM, CLSI (formerly NCCLS), and CAP standards

pure

transform

take off

oxygen

flow

Cheng

and

be

unify

match

place

Pre processing

Triple pre filter: includes one 10 inch 5-micron PP cotton filter, one 10 inch activated carbon filter, and one 10 inch 1-micron PP cotton filter. They can effectively remove sediment, rust, large organic particles, and chlorine from tap water.

Reverse osmosis membrane element

Reverse osmosis membrane element, also known as RO membrane: using * reverse osmosis membrane, the desalination rate reaches 99%, effectively removing impurities such as inorganic salts, heavy metal ions, organic matter, colloids, bacteria, viruses, etc. from the source water. The major difference between domestically produced RO membranes and imported ones is that imported ones have more stable water quality and longer lifespan. Generally, it should be replaced every 2-3 years.

Ion exchange element

Pre purification column: Adopting PVC molding technology for one-time molding, the appearance is clean and beautiful, easy to replace. The purification column is filled with American Dusheng nuclear grade polishing resin, and the water production capacity is greater than 2.0T. Ensure the water quality of DI water

Superior to the laboratory's standard for two water, this is the standard for other purification columns.

Ultra purification column: using PVC molding technology for one-time molding, the appearance is clean and beautiful, easy to replace. The ultra purification column is filled with American Dusheng nuclear grade polishing resin, and the water production capacity is greater than 4.0T. Ensure the water content of UP water

Better quality than laboratory water standards.

Boosting and circulation components

The pressurization and circulation components of the system are also called booster pump and circulation pump: both of them use the DC stabilized pressure pump from Taiwan, China, China as the pressurization component of the system, which has the characteristics of stable pressure, low noise, low power consumption, long life, small volume, large head, etc.

Computer control components

Computer control components, also known as computer control boards or motherboards, are independently developed and produced by our company. They are the core components of pure water machines, and due to the use of microcontroller chips, they have extremely low failure rates, stable and reliable operation, complete functions, and are easy to replace and use. Equipped with fully automatic operation, no need for duty, high-precision sensor detection and control, automatic shutdown when water is cut off or full, automatic startup and replenishment when the water tank is short of water, and automatic anti fouling and scaling 40 second flushing of the RO membrane, effectively extending the service life of the RO membrane.

Detection and display components

Detection and display components: The conductivity/resistivity meter is selected with a measurement certificate, and the system LCD backlight LCD is used for online detection and display, accurately and intuitively displaying the conductivity/resistivity of the produced water quality. The temperature compensation of the flow cell is automatic ± 0.1 ℃, the electrode constant is 0.01cm-1, the measurement range is 0.00-18.25 M Ω. cm, the measurement accuracy is ± 1% (F.S) or 0.00-100.00us.cm, and the measurement accuracy is ± 1% (F.S). The detection and display of total dissolved oxygen content use imported probes with a measurement accuracy of ± 1%, making online detection and display more intuitive.

UV lamp components

The UV lamp used is a dual wavelength 185/245 UV lamp, which effectively removes bacteria such as microorganisms and heat sources, ensuring the water quality requirements of the produced water.

Vacuum control components

The vacuum control component adopts a water circulation method, with stable and reliable vacuum degree, low noise, and stable operation.

Pure water storage

Storage device: 20-70L fully automatic nitrogen sealed water tank is available for selection. Ensure the dissolved oxygen index of anaerobic water output, pure water purity, and constant pressure.