- Phone
-
Address
High tech West Zone, Pidu District
Sichuan Huayu Instrument Co., Ltd
High tech West Zone, Pidu District
ZH-Q3000Small animal energy metabolism monitoring system
1、 Product Introduction:
The animal metabolism monitoring system has the advantages of multi flux, real-time statistics, automation, and high accuracy, greatly improving the efficiency of drug development and basic life science research, and fundamentally reducing data bias and errors caused by manual operations.
In the unconstrained state of animals, multi-channel measurement is carried out, and the recording software can real-time calculate the diet, water intake, exercise, energy metabolism and other indicators of mice and rats. The design of the feeding trough prevents the mixing of feces and the scattering of feed, and the collection of metabolic gases can achieve short-term and long-term multi-channel monitoring.
Suitable for research fields such as pharmacology, pharmacology, toxicology, nutrition, obesity metabolism, energy metabolism, cardiovascular disease, and genetic modification.
2、 Product parameters:
1.1 This system adopts high-speed and high-sensitivity sensors, which can quickly and accurately measure parameters such as respiratory entropy, oxygen consumption, and carbon dioxide production.
1.2 Detector parameters:
Oxygen measurement range: 0-25%
Oxygen measurement accuracy: ≤ 0.01%
Oxygen measurement resolution: ≤ 0.001%
Carbon dioxide measurement range: 0-1%
Carbon dioxide measurement accuracy: ≤ 0.0001%
Carbon dioxide measurement resolution: ≤ 0.00001%
Temperature measurement range: -40--80 ℃
Temperature measurement accuracy: ± 0.3 ℃
Temperature measurement resolution: 0.1 ℃
Humidity measurement range: 0-99.9% RH
Humidity measurement accuracy: ± 0.2% RH
Humidity measurement resolution: 0.1% RH
1.3 Gas measurement speed:
The system is equipped with an advanced ventilation system, with a ventilation rate of 16L/min for the air pump and a ventilation rate of no less than 15 times per hour for the cage. Fluorescence oxygen sensors and non dispersive infrared carbon dioxide sensors are used, and the detection time for single cage oxygen and carbon dioxide is ≤ 15 seconds.
1.4 The system can automatically calibrate the oxygen and carbon dioxide values.
1.5 The system can expand the water vapor removal device and measure the water vapor content.
1.6 System configuration environment monitoring system, which can monitor the changes in oxygen and carbon dioxide content in the reference air in real time, and also monitor the temperature inside the cage.
1.7 System monitoring has flexibility, and the monitoring process can be adjusted according to specific experimental needs without a maximum measurement time limit.
The 1.8 system can simultaneously achieve animal metabolism monitoring experiments in channels 1-18.
1.9 The system is equipped with an independent living cage system, adopting environmentally friendly design, collecting excrement, suitable for long-term monitoring, and the cage body can be sterilized under high temperature and pressure.
2. Eating monitoring module:
2.1 The system can monitor and record food consumption in real-time, with a measurement accuracy of 0.001g and a display accuracy of 0.01g.
2.2 The food dispenser hasZhu Li(zhuanbenefitThe feeding leakage prevention device (No. 6832589) can avoid errors caused by debris loss and leakage during the feeding process.
2.3 Food can be added during system operation without affecting continuous monitoring.
2.4 Number of channels that can be monitored simultaneously: 1-18.
3 Drinking water monitoring module:
3.1 The system can accurately monitor and record drinking water consumption, with a measurement accuracy of 0.001g and a display accuracy of 0.01g.
Adding water during system operation will not affect continuous detection.
3.3 Number of channels that can be monitored simultaneously: 1-18.
4 Weight monitoring module:
4.1 The system can accurately monitor the weight of animals living in cages, with a measurement accuracy of 0.001g and a display accuracy of 0.01g.
4.2 Number of channels that can be monitored simultaneously: 1-18.
5 Running Wheel Movement Monitoring Module:
5.1 The system's wheel running motion monitoring module can measure the number of rotations and distance traveled through Hall sensors
5.2 Mouse running wheel diameter 125mm, width 56mm.
The diameter of the rat running wheel is 250mm and the width is 80mm.
5.3 Number of channels that can be monitored simultaneously: 1-18.
6. System hardware dimensions:
Cage frame size: 150 * 46 * 183cm
Monitoring electrical dimensions: 330 * 305 * 105mm
Monitoring cage size: 465 * 300 * 185mm
7 Data Analysis System:
7.1 The system has independently developed multi-channel capabilitiesSmall animal energy metabolism monitoring systemIn addition to the conventional function of recording experimental results, software can also effectively analyze and plot raw data, and extract and export data segments for further statistical analysis.
7.2 Analysis software system, collected dataWan QuanTraceable.
7.3 System analysis software system does not requireAdd Mi DogConvenient for later data processing and analysis.
7.4 The analysis software system can be installed on any number of computers,Finally, Shen is freetechnical support.