Instrument features:
Stable and reliable
According to the requirements of industrial and environmental online, the electrical and hydraulic pipeline parts are completely integrated. This simple and stable LFA system structure ensures the high stability of the analyzer in electrical, hydraulic and other aspects, ensuring that the analyzer can operate stably for a long time.
Easy to install
When installing the analyzer, simply connect the reagent tube, sample tube, pure water tube, waste liquid tube, and power cord, and set the parameters to start.
Automatic calibration
The analyzer performs calibration based on the calibration time and calibration type set by the user. The calibration results obtained will be compared with the calibration results stored in the original analyzer. If it is less than the error limit set by the user, the original calibration parameters will be accepted and replaced. If it is greater than the limit set by the user, the original calibration parameters will not be replaced and an alarm signal will be output.
Automatic dilution
Can automatically dilute high concentration samples.
The measurement interval can be freely set according to the actual situation
Users can set the measurement time interval. The analyzer remained in standby mode between two measurements, avoiding wastage of reagents.
Technical parameters:
|
Measurement principle: |
Molybdate photometric method |
|
Photometer: |
660nm dual beam colorimeter |
|
Measurement type: |
User manual or set interval automatic analysis |
|
Measurement interval: |
Free programming according to actual situation |
|
Measurement range: |
0~0.5 mg/L, Scalable |
|
Repeatability: |
<1.5% |
|
Zero drift: |
±3% |
|
Range drift: |
±3% |
|
resolution |
0.001 |
|
Signal output: |
Standard 4-20mA analog output, maximum load of 400 ohms; Standard RS232 digital interface |
|
INPUT |
1-way analysis, 1-way correction |
|
call the police: |
1 high limit alarm, 1 calibration, 1 regular alarm |
|
Medication replacement: |
3-4 weeks, depending on the ambient temperature |
|
ambient temperature |
5~40℃ |
|
Protection level: |
IP55 |
|
Power supply: |
220VAC ,50/60Hz; |
|
Weight: |
33kg (excluding medication) |
|
Size: |
800×620×300mm(h×w×d) |
|
Hardware |
Industrial Standard 104 Computer, including Chinese version of operating system |