NiCaVis 705IQ discharge outlet COD, BOD, TOC nitrate nitrogen online sensor

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Instrument: Nitrogen online sensor Model: NiCaVis705IQ Discharge outlet COD, BOD, TOC Brand: Zhongqing Environmental Protection

Product Details


      characteristic

      • Four models
        - CarboVis®CODsensor
        - NitraVis®Nitrous nitrogen sensor
        - NiCaVis®COD\\Nitrous nitrogen sensor
        - NiCaVis®NICOD\\Nitrate nitrogen\\Nitrous nitrogen sensor

      • on-line measurementCODBODTOCTSSAnd nitrate nitrogen, nitrite nitrogen

      • The patented optical system ensures accuracy, stability, and reliability

      • Full spectrum assurance results and compensation

      • Ultrasonic cleaning system ensures good maintenance

      • Titanium alloy andPEEKMaterial, more resistant to chemical corrosion

      • Standard plastic cushioning protective cap, impact resistant, super durable



      overview

      The new spectral sensor has a diameter of60mmThe sensor contains a set of precise spectral analysis components, which can accurately analyze the organic pollution concentration at the inlet, biochemical tank or discharge outlet of municipal sewage plants in the ultraviolet visible bandCODBODTOCDOCSACIt can also be testedTSSTotal suspended solids concentration, nitrate nitrogen, and nitrite nitrogen concentration. Easy to use, no need for reagents, no need for sample pretreatment.

      The patented optical system design ensures measurement accuracy, stability, and reliability. The drift free sensor ensures reliable data even after long-term use without the need for routine maintenance. Using a complete full spectrum length range from200nmarrive720nmperhaps200-390nmCompared to the single wavelength or multi wavelength principle, it has better measurement results and compensation for interfering materials such as turbidity. The built-in ultrasonic cleaning system reduces manual window cleaning time and can also add compressed air cleaning for special harsh environmental applications. Using high-tech materials-Titanium alloy andPEEkIt can be used in very harsh environments and has a long service life.

      measuring principle

      The basic working principle is UV visible continuous spectral scanning. When a beam of light passes through the test liquid, any substance in the liquid will absorb the light, reducing the intensity of the transmitted light. The instrument measures the absorbance at different wavelengths to depict the absorption curve. By analyzing the absorption curve, the test component can be qualitatively and quantitatively tested. At the same time, solid particles in the liquid will scatter light in various directions, causing a decrease in the intensity of transmitted light (at all wavelengths). Continuous spectral scanning can effectively compensate for the influence of changes in the background composition of the tested liquid. The probe tested using this method has a certain testing interval and cannot be tested continuously.

      WTWThe spectral sensor adopts an optical design, with a symmetrical measurement system and reference system, the same optical elements, light intensity, light quantity, and optical path length, so it has automatic drift compensation and does not require conventional zeroing.

      NitraVis /CarboVis /NiCaVisOptical sensors can automatically adjust the flicker frequency of the light source according to different samples, ensuring that the light signal is neither too strong nor too weak, with a very low signal-to-noise ratio and reliable measurement data.





      Reliable measurement

      UV/VISsensorCODtotalAnd the laboratoryCODComparison Chart

      UV/VISsensorCODtotalAnd the laboratoryCODComparison Chart

      Automatic cleaning

      Ultrasonic cleaning system

      The probe is equipped with an ultrasonic cleaning system as standard, which ensures long-term reliable operation and saves maintenance. Optical lenses will vibrate slightly under the action of ultrasound, which can effectively prevent pollutants from adhering to the optical lenses, greatly improving the stability and reliability of testing.

      Air blowing device (optional)

      When the on-site conditions are extremely harsh, it is recommended that users choose another set of high-pressure air blowing device to achieve dual safety and ensure the reliable operation of the system.

      structure

      Refer to the figure below, from the light source1The emitted light passes through a lens2After diffusion, it enters the measuring cell in the form of parallel light3, then through a converging lens4 After focusing, it reaches the detector5Generate sensing signals. In the figure,6To measure the signal, there is a test liquid passing through it,7As reference signals, without testing the liquid, these two sets of signals are received by photodiodes and converted into current signals, which are then converted into the required component concentrations through certain algebraic operations.

      1 light source 2 Diffusion lens 3 Measure optical path length 4focusing lens

      5 detector 6 measuring beam 7 Reference beam 8Compressed air nozzle

      External dimensions

      Without seismic protection cap

      Equipped with seismic protection cap

      Multiparameter measurement

      Spectral sensors can provide multi parameter measurement of carbon

      • at most5Carbon parameters can be measured, displayed, and transmitted simultaneously,
        COD total/ COD soluble/ TOC/ BOD/ DOC/ SAC/ SAC soluble/ UVT254Choose five out of eight

      • increase254nmPenetration measurement(UVT254)

      • CODThe solubility algorithm can be used forWWTPApplication in Aeration Tank(Like denitrification/Methanol control

      NitraVis /CarboVis /NiCaVisOptical sensors have multiple cleaning methods, including ultrasonic cleaning or compressed air cleaning, as well as composite mode ultrasonic cleaning+Compressed air cleaning. The sensor will automatically select the cleaning cycle. If you choose to blow with air, you need to set the corresponding relay function.

      Technical Parameter

      model

      NitraVis
      705 IQ

      NitraVis
      701 IQ

      CarboVis
      705 IQ

      CarboVis
      701 IQ

      NiCaVis
      705 IQ

      NiCaVis
      701 IQNI

      NiCaVis
      705 IQNI


      measuring principle

      UV-VIScontinuous spectrum200-720nm

      UVcontinuous spectrum200-390nm


      application

      Discharge port

      Entrance, aeration tank

      Discharge port

      Entrance, aeration tank, and discharge outlet

      Discharge port

      Entrance, aeration tank, and discharge outlet

      Discharge port


      measuring range

      [mg/l]

      NO3-N:
      0.01…25.00

      NO3-N:
      0.01…100.0

      COD:
      0.1…800.0

      BOD:
      0.1… 500.0

      TOC:
      1…500.0

      SAC:
      0.1…600.0

      COD:
      0.5…4000

      BOD:
      12500

      TOC:
      5…2500

      SAC:
      0.5…3000

      COD:
      0.1…800.0

      BOD:
      0.1… 500.0

      TOC:
      1…500.0

      SAC:
      0.1…600.0

      NO3-N:
      0.01…25.00

      NO2-N:

      0.00-75.00mg/L

      NO3-N:

      0.00-150.0mg/l

      COD:0-20000mg/L

      TOC:0-20000mg/L

      SAC:0-5000m

      DOC0-12500mg/L

      BOD0-8000mg/L

      UVT:0.00-100%

      NO2-N:

      0.00-25.00mg/L

      NO3-N:

      0.00 -50mg/L

      COD:

      0.0-800.0mg/L

      TOC:0.0-500.0mg/L

      SAC:0.00-600.0m

      DCO:0.0-500.0mg/L

      BOD:0.0-500.0mg/L

      UVT:0.00-100%


      TSS
      (Optional)

      Entrance, aeration tank:
      0 … 10.00 g/l TS

      Discharge port:
      0 … 900.0 mg/l TS

      entrance:
      0 … 3000 mg/l TS

      Discharge port:
      0.0 … 900.0 mg/l TS

      entrance:
      0 … 15
      g/l TS

      Discharge port:
      0 … 4.5
      g/l TS


      Mechanical Construction

      Shell: Titanium alloy3.7035PEEKLens: Sapphire

      pHrange

      pH 4… pH 12

      velocity of flow

      ≤3rice/second

      Maximum pressure

      less than1 hope earnestly

      Immersion depth

      At least the measuring tank should be submerged in the water sample, at most10 Depth in meters

      Position orientation

      arbitrary

      size

      802 × 59.9mm(Length)XDiameter)

      weight

      make an appointment4Kg

      power consumption

      8W

      Warranty period

      Two years

      Ordering Information

      model

      describe

      order No

      NitraVis ® 701 IQ

      Nitrous nitrogen UV visible spectroscopy probe with built-in ultrasonic cleaning

      481 044

      NitraVis ® 701 IQ TSdouble probe

      Same as above, suspended solid concentration can also be tested

      481 045

      NitraVis ® 705 IQ

      Nitrous nitrogen UV visible spectroscopy probe with built-in ultrasonic cleaning

      481 046

      NitraVis ® 705 IQ TSdouble probe

      Same as above, suspended solid concentration can also be tested

      481 047

      CarboVis ® 701 IQ

      COD/BOD/TOC/DOC/SACSpectral probe with built-in ultrasonic cleaning

      481 048

      CarboVis ® 701 IQ TSdouble probe

      Same as above, suspended solid concentration can also be tested

      481 049

      CarboVis ® 705 IQ

      COD/BOD/TOC/DOC/SACSpectral probe with built-in ultrasonic cleaning

      481 050

      CarboVis ® 705 IQ TSdouble probe

      Same as above, suspended solid concentration can also be tested

      481 051

      NiCaVis ® 705 IQ double probe

      COD/BOD/TOC/DOC/SAC/NO3Spectral probe with built-in ultrasonic cleaning

      481 052

      NiCaVis ® 701 IQ NI

      UVSensors are used to measure nitrite, nitrateCODTOCBODDOCSACAndUVT254

      481054

      NiCaVis ® 705 IQ NI

      UVSensors are used to measure nitrite, nitrateCODTOCBODDOCSACAndUVT254