Welcome Customer !

Membership

Help

Beijing Zhongqing Guotou Environmental Protection Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Zhongqing Guotou Environmental Protection Technology Co., Ltd

  • E-mail

    eric@sdicelc.com

  • Phone

    18911571363

  • Address

    15th Floor, Building 6, Courtyard 2, Wuliqiao Second Street, Chaoyang District, Beijing

Contact Now

NiCaVis 705IQ Spectral Method Online COD, BOD, Nitrate Sensor

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Instrument: Spectral online COD, BOD, nitrate sensor model: NiCaVis705IQ Measurement principle: UV spectroscopy Brand: WTW Germany

Product Details

    characteristic

    • Four models
      - CarboVis®CODsensor
      - NitraVis®Nitrous nitrogen sensor
      - NiCaVis®COD\\Nitrous nitrogen sensor
      - NiCaVis®NICOD\\Nitrate nitrogen\\Nitrous nitrogen sensor

    • on-line measurementCODBODTOCTSSAnd nitrate nitrogen, nitrite nitrogen

    • The patented optical system ensures accuracy, stability, and reliability

    • Full spectrum assurance results and compensation

    • Ultrasonic cleaning system ensures maintenance

    • Titanium alloy andPEEKMaterial, more resistant to chemical corrosion

    • Standard plastic cushioning protective cap, impact resistant, super durable

    overview

    The new spectral sensor has a diameter of60mmThe sensor contains a set of precise spectral analysis components, which can accurately analyze the organic pollution concentration at the inlet, biochemical tank or discharge outlet of municipal sewage plants in the ultraviolet visible bandCODBODTOCDOCSACIt can also be testedTSSTotal suspended solids concentration, nitrate nitrogen, and nitrite nitrogen concentration. Easy to use, no need for reagents, no need for sample pretreatment.

    The patented optical system design ensures measurement accuracy, stability, and reliability, while the drift free sensor ensures reliable data even after prolonged use without the need for routine maintenance. Using a complete full spectrum length range from200nmarrive720nmperhaps200-390nmCompared to the single wavelength or multi wavelength principle, it has better measurement results and compensation for interfering materials such as turbidity. The built-in ultrasonic cleaning system reduces manual window cleaning time and can also add compressed air cleaning for special harsh environmental applications. Using high-tech materials-Titanium alloy andPEEkIt can be used in very harsh environments and has a long service life.

    measuring principle

    The basic working principle is UV visible continuous spectral scanning. When a beam of light passes through the test liquid, any substance in the liquid will absorb the light, reducing the intensity of the transmitted light. The instrument measures the absorbance at different wavelengths to depict the absorption curve. By analyzing the absorption curve, the test component can be qualitatively and quantitatively tested. At the same time, solid particles in the liquid will scatter light in various directions, causing a decrease in the intensity of transmitted light (at all wavelengths). Continuous spectral scanning can effectively compensate for the influence of changes in the background composition of the tested liquid. The probe tested using this method has a certain testing interval and cannot be tested continuously.

    WTWThe spectral sensor adopts an optical design, with a symmetrical measurement system and reference system, the same optical elements, light intensity, light quantity, and optical path length, so it has automatic drift compensation and does not require conventional zeroing.

    NitraVis /CarboVis /NiCaVisOptical sensors can automatically adjust the flicker frequency of the light source according to different samples, ensuring that the light signal is neither too strong nor too weak, with a very low signal-to-noise ratio and reliable measurement data.



    Reliable measurement






    UV/VISsensorCODtotalAnd the laboratoryCODComparison Chart



    UV/VISsensorCODtotalAnd the laboratoryCODComparison Chart




    Automatic cleaning

    NitraVis /CarboVis /NiCaVisOptical sensors have multiple cleaning methods, including ultrasonic cleaning or compressed air cleaning, as well as composite mode ultrasonic cleaning+Compressed air cleaning. The sensor will automatically select the cleaning cycle. If you choose to blow with air, you need to set the corresponding relay function.

    Ultrasonic cleaning system

    The probe is equipped with an ultrasonic cleaning system as standard, which ensures long-term reliable operation and saves maintenance. Optical lenses will vibrate slightly under the action of ultrasound, which can effectively prevent pollutants from adhering to the optical lenses, greatly improving the stability and reliability of testing.

    Air blowing device (optional)

    When the on-site conditions are extremely harsh, it is recommended that users choose another set of high-pressure air blowing device to achieve dual safety and ensure the reliable operation of the system.




    structure

    Refer to the figure below, from the light source1The emitted light passes through a lens2After diffusion, it enters the measuring cell in the form of parallel light3, then through a converging lens4 After focusing, it reaches the detector5Generate sensing signals. In the figure,6To measure the signal, there is a test liquid passing through it,7As reference signals, without testing the liquid, these two sets of signals are received by photodiodes and converted into current signals, which are then converted into the required component concentrations through certain algebraic operations.


    External dimensions

    Multiparameter measurement

    Spectral sensors can provide multi parameter measurement of carbon

    • at most5Carbon parameters can be measured, displayed, and transmitted simultaneously,
      COD total/ COD soluble/ TOC/ BOD/ DOC/ SAC/ SAC soluble/ UVT254Choose five out of eight

    • increase254nmPenetration measurement(UVT254)

    • CODThe solubility algorithm can be used forWWTPApplication in Aeration Tank(Like denitrification/Methanol control

      Technical Parameter

    model

    NitraVis
    705 IQ

    NitraVis
    701 IQ

    CarboVis
    705 IQ

    CarboVis
    701 IQ

    NiCaVis
    705 IQ

    NiCaVis
    701 IQNI

    NiCaVis
    705 IQNI


    measuring principle

    UV-VIScontinuous spectrum200-720nm

    UVcontinuous spectrum200-390nm


    application

    Discharge port

    Entrance, aeration tank

    Discharge port

    Entrance, aeration tank, and discharge outlet

    Discharge port

    Entrance, aeration tank, and discharge outlet

    Discharge port


    measuring range

    [mg/l]

    NO3-N:
    0.01…25.00

    NO3-N:
    0.01…100.0

    COD:
    0.1…800.0

    BOD:
    0.1… 500.0

    TOC:
    1…500.0

    SAC:
    0.1…600.0

    COD:
    0.5…4000

    BOD:
    12500

    TOC:
    5…2500

    SAC:
    0.5…3000

    COD:
    0.1…800.0

    BOD:
    0.1… 500.0

    TOC:
    1…500.0

    SAC:
    0.1…600.0

    NO3-N:
    0.01…25.00

    NO2-N:

    0.00-75.00mg/L

    NO3-N:

    0.00-150.0mg/l

    COD:0-20000mg/L

    TOC:0-20000mg/L

    SAC:0-5000m

    DOC0-12500mg/L

    BOD0-8000mg/L

    UVT:0.00-100%

    NO2-N:

    0.00-25.00mg/L

    NO3-N:

    0.00 -50mg/L

    COD:

    0.0-800.0mg/L

    TOC:0.0-500.0mg/L

    SAC:0.00-600.0m

    DCO:0.0-500.0mg/L

    BOD:0.0-500.0mg/L

    UVT:0.00-100%


    TSS
    (Optional)

    Entrance, aeration tank:
    0 … 10.00 g/l TS

    Discharge port:
    0 … 900.0 mg/l TS

    entrance:
    0 … 3000 mg/l TS

    Discharge port:
    0.0 … 900.0 mg/l TS

    entrance:
    0 … 15
    g/l TS

    Discharge port:
    0 … 4.5
    g/l TS


    Mechanical Construction

    Shell: Titanium alloy3.7035PEEKLens: Sapphire

    pHrange

    pH 4… pH 12

    velocity of flow

    ≤3rice/second

    Maximum pressure

    less than1 hope earnestly

    Immersion depth

    At least the measuring tank should be submerged in the water sample, at most10 Depth in meters

    Position orientation

    arbitrary

    size

    802 × 59.9mm(Length)XDiameter)

    weight

    make an appointment4Kg

    power consumption

    8W

    Warranty period

    Two years

    Ordering Information

    model

    describe

    order No

    NitraVis ® 701 IQ

    Nitrous nitrogen UV visible spectroscopy probe with built-in ultrasonic cleaning

    481 044

    NitraVis ® 701 IQ TSdouble probe

    Same as above, suspended solid concentration can also be tested

    481 045

    NitraVis ® 705 IQ

    Nitrous nitrogen UV visible spectroscopy probe with built-in ultrasonic cleaning

    481 046

    NitraVis ® 705 IQ TSdouble probe

    Same as above, suspended solid concentration can also be tested

    481 047

    CarboVis ® 701 IQ

    COD/BOD/TOC/DOC/SACSpectral probe with built-in ultrasonic cleaning

    481 048

    CarboVis ® 701 IQ TSdouble probe

    Same as above, suspended solid concentration can also be tested

    481 049

    CarboVis ® 705 IQ

    COD/BOD/TOC/DOC/SACSpectral probe with built-in ultrasonic cleaning

    481 050

    CarboVis ® 705 IQ TSdouble probe

    Same as above, suspended solid concentration can also be tested

    481 051

    NiCaVis ® 705 IQ double probe

    COD/BOD/TOC/DOC/SAC/NO3Spectral probe with built-in ultrasonic cleaning

    481 052

    NiCaVis ® 701 IQ NI

    UVSensors are used to measure nitrite, nitrateCODTOCBODDOCSACandUVT254

    481054

    NiCaVis ® 705 IQ NI

    UVSensors are used to measure nitrite, nitrateCODTOCBODDOCSACandUVT254

    481055