Ship fire extinguishing system with fine water mist alarm device
summary
Can control8A fire extinguishing zone.
The detector indicator light adopts a dual color light, which lights up red in case of fire alarm and yellow in case of malfunction, making it more suitable for user use.
equipped with3There are various ways to start the fire extinguishing area, including automatic start, manual start on site, and manual start on the controller.
Monitor whether the solenoid valves in each zone are disconnected.
When there is a feedback signal in the fire extinguishing area, give a spraying instruction
Monitor the status of the water pump to ensure the normal operation of this controller.
To prevent accidental operation of this controller, it is equipped with a lock key function.
Compliant with fixed local water-based(water mist)Requirements for the use of fire extinguishing systems.
Technical Specifications
main power supply :AC 220V (+10%~-15%),50Hz
Ship fire extinguishing system with fine water mist alarm device
Marine auxiliary power supply:DC 24V (+10%~-10%)
power consumptionPower: Monitoring state:≤2.4W
Alarm state:≤10W
Basic control capacity of fire extinguishing area
:8Each fire extinguishing zone has a starting current not exceeding1AWhen starting simultaneously, the total starting current of each fire extinguishing zone shall not exceed3A.
Pump start signal mode
Normally open passive contacts, maximum output contact current is7A
Various pump status inputs
All are passive normally open contacts
Using wires
The signal line adopts a cross-section not less than1.5mm2Marine communication cable
The power cord adopts a cross-sectional area not less than2.5mm2Marine power cables.
External control contact: fire alarm output contactFIREFault output contactFAULT,Spray in output contactSPRAY,Everyone has it3Passive normally open and normally closed contact output.
External fine water mist display panel capacity:1a
Fire alarm output contact:3Immediate fire alarm output, passive.
Fault output contact:3Fault output, passive.
Working environment temperature:.5°C 55°C
Relative humidity: ≤95%
Overall dimensions:290X180X51 mm 2Embedded host( 540X380X140mm2junction box
Protection level:IP32