- Phone
-
Address
6th Floor, Building 7, Chuangmei Huacai Center, Xihu District, Hangzhou City, Zhejiang Province
Hangzhou Ruixi Technology Co., Ltd
6th Floor, Building 7, Chuangmei Huacai Center, Xihu District, Hangzhou City, Zhejiang Province
Shimadzu series high-performance liquid chromatography integrated machinesummary:
Shimadzu original Prominence-i LC-2030 series high-performance liquid chromatography all-in-one machine from Japan
No need to perform analysis operations from PC
·The operation from sample loading to analysis can be carried out next to the device
·Minimize the analysis operations of analysts in the laboratory
·Even from places outside the laboratory, the analytical condition of the instrument can be confirmed
·Can effectively utilize laboratory space
Pursuing operational simplicity
The unified user interface between the device and software allows intuitive operation even if unfamiliar with the user interface, further improving the efficiency of i-Series operation. By utilizing the browser function, not only can a large number of analysis results be quickly processed, but also the statistical calculation and outlier determination of the analysis results can be confirmed at a glance, effectively supporting the data analysis work of analysts
Demonstration video of Shimadzu's original Prominence-i LC-2030 series high-performance liquid chromatography all-in-one machine
Intelligent solutions to improve analysis efficiency
I-Series reduces the working hours of laboratory analysts. By combining with LabSolutions' automation functions, reliable analysis can be implemented according to the prescribed analysis steps. The function of email notification for analysis completion allows analysts to focus and concentrate on other tasks without worrying about the end time of the analysis
Shimadzu series high-performance liquid chromatography integrated machineTechnical Indicators:
Prominence-i LC-2030 series | |||
Intravenous infusion* |
LC-2030LC-2030 |
LC-2030CLC-2030C |
LC-2030C 3DLC-2030C 3D |
Degassing unit |
5 channels: 4 mobile phases+1 cleaning solution (volume 400 μ L) |
||
Infusion method |
Parallel double plunger |
||
pressure pulsation |
≤0.1MPa(1.0mL/min,10MPa, 水) |
||
Flow rate setting range |
0.0001-10 mL/min |
||
Traffic accuracy |
≤± 1% or ≤± 2 μ L/min, with the larger value (0.01-2 mL/min, required condition) ≤± 2% (2-5 mL/min, required condition) |
||
Flow precision |
<0.06% RSD or<0.02 minSD, whichever is higher |
||
Gradient method |
Four element low-pressure gradient |
||
Gradient setting range |
0-100%, 0.1% step |
||
Gradient accuracy |
± 0.5% (0.1-2 mL/min, 1-20 MPa, required conditions) |
||
Gradient precision |
± 0.1% (1mL/min, 10 MPa, required conditions) |
||
Maximum pressure resistance |
44 MPa (0.0001-5 mL/min), 22 MPa (5.0001-10 mL/min) |
||
autosampler |
LC-2030LC-2030 |
LC-2030CLC-2030C |
LC-2030C 3DLC-2030C 3D |
Injection method |
Full volume injection |
||
Injection volume accuracy |
±1% (50μL,N=10) |
||
Range of injection volume setting |
0.1-100 μ L (standard), 0.1-50 μ L, 1-500 μ L, 1-2000 μ L (optional) |
||
Reproducibility of injection volume |
RSD<0.20%(5.0-2000μL),RSD<0.25%(2.0-4.9μL),RSD<0.5%(1.0-1.9μL),RSD<1.0%(0.5-0.9μL) |
||
cross-contamination |
0.0025% (* * *, required condition) |
||
Injection cycle |
Minimum 14 seconds (required condition) |
||
Sample warehouse capacity |
336(1mL),216(1.5mL),112(4mL),4(MTP/DWP) |
||
Sample cooling |
not supported |
4-45 ° C (As low as 4 ° C, the room temperature should be below 30 ° C and the humidity should be less than 70%) |
|
Injection linearity |
>0.9999 (1-100 μ L, required conditions) |
||
column oven |
LC-2030LC-2030 |
LC-2030CLC-2030C |
LC-2030C 3DLC-2030C 3D |
Temperature control method |
Forced air circulation type |
||
Can accommodate chromatographic columns |
Up to 6 10cm columns, 3 10-30cm columns |
||
Temperature control range |
(Room temperature -10) -85 ° C, 4-85 ° C, 1 ° C step |
||
Temperature control accuracy |
±0.1°C |
||
Flow path switching valve |
At most 1 |
||
UV detector |
LC-2030LC-2030 |
LC-2030CLC-2030C |
LC-2030C 3DLC-2030C 3D |
wavelength range |
190 - 700 nm |
not supported |
|
Spectral bandwidth |
8nm |
||
wavelength accuracy |
≤±1nm |
||
Wavelength reproducibility |
≤±0.1nm |
||
noise |
≤± 2.5X10-6AU, (250nm, condition) |
||
drift |
≤ 100X10-6AU/h, (250nm, condition) |
||
Dual wavelength detection |
Supports (190-370 nm or 371-700 nm) |
||
linear range |
2.5AU(5%) |
||
sampling frequency |
100 Hz |
||
light source |
D2 lamp |
||
liquidity pool |
12μL(10mm,TC),12,MPa |
||
Optional pool |
Rapid cell: 8 μ L (10 mm, TC), Semi micro cell: 2.5 μ L (5mm, TC) |
||
PDA detector |
LC-2030LC-2030 |
LC-2030CLC-2030C |
LC-2030C 3DLC-2030C 3D |
wavelength range |
not supported |
190 - 800 nm |
|
spectral resolution |
1.4nm (condition) |
||
Narrow slit width |
1.2nm,8nm |
||
Number of diodes |
1024 |
||
wavelength accuracy |
≤±1nm |
||
noise |
≤± 3X10-6AU, (250nm, reference: 350nm, conditions) |
||
drift |
≤ 500X10-6AU/h (250nm, reference: 350nm, conditions) |
||
linear range |
2 AU (5%) |
||
sampling frequency |
100 Hz |
||
light source |
D2 light (standard); W lamp (optional) |
||
liquidity pool |
10μL(10mm,TC)12Mpa |
||
Optional pool |
Rapid cell: 8 μ L (10mm, TC), Semi micro cell: 2.5 μ L (5mm, TC) |
||
Other parameters |
LC-2030LC-2030 |
LC-2030CLC-2030C |
LC-2030C 3DLC-2030C 3D |
size |
W410xH605xD500mm |
||
weight |
58kg |
63kg |
|
pH range |
1--13 |
||
Contact with liquid materials |
Stainless steel (SUS316L, SUS316), FEP, PEEK, PTFE, perfluororubber, ruby, sapphire, nickel alloy, ultra-high molecular weight polyethylene, ceramics, phenolic resin, quartz, PPS |
||
Common configurations
NOS. |
Parts No. |
Description |
Q'TY |
|
(Shimadzu LC-2030+VWD UV detector+100 position liquid automatic sampler+column temperature box+original chromatography workstation+computer printer high-performance liquid chromatography configuration list) | ||||
LC-2030 (UV without Cooler) comes standard with a UV detector and does not come with sample cooling | ||||
Main unit |
host |
|||
1 |
228-45200-58 includes |
LC-2030 (Main unit) UV without Cooler |
1 |
set |
Pump unit, 泵 |
||||
Degasser unit, Degassing machine |
||||
Low pressure gridient unit, Low pressure gradient unit |
||||
Mixer, mixer |
||||
UV detector, UV detector |
||||
Column oven , column oven |
||||
Auto sampler without sample cooler, |
||||
2 |
228-45220-46 Attachment Pack |
Accessory kit for LC-2030 |
1 |
set |
3 |
228-57647-41 tool kit |
Tool Kit toolkit |
1 |
set |
4 |
228-38583-42 mobile phase bottle |
1 L Phase Bottle (5 pcs) Mobile phase bottle (1L, pack of 5) |
1 |
pc |
5 |
228-15652-92 1.5mL sample bottle |
1.5 mL Sample Vial 1.5 mL Sample Bottle (Glass, 100pcs, w/cap, silicone rubber septum) (Glass, 100 pieces, including bottle cap, silicone rubber spacer) |
1 |
pkg |
Workststion |
workstation |
|||
6 |
465-06266-91 Workstation |
LabSolutions LC Workstation Ver.5 Single LC (Chinese version) |
1 |
pc |
Packed columns |
chromatographic column |
|||
7 |
5020-07346 chromatographic column |
InertSustain C18 5um 4.6 x 250mm, chromatographic column |
1 |
pc |
8 |
5020-19049 Protection Column Core (2/Pack) |
InertSustain C18 5um 2 CARTRIDGES, 4.0mm I.D.(2pcs/pkg), Protection column core (2/pack) |
1 |
pc |
9 |
5020-08500 protective column sleeve |
Guard Column HOLDER for 10mm length , Protective column sleeve (4.0mm I. D column) |
1 |
pc |
NOS. |
Parts No. |
Description |
Q'TY |
|
List of Configuration for High Performance Liquid Chromatography with LC-2030C, PDA Diode Array Detector, 100 Position Liquid Automatic Sample Injector (with Sample Cooling), Column Temperature Chamber, Original Chromatography Workstation, and Computer Printer Imported from Shimadzu, Japan | ||||
LC-2030C 3D (PDA with Cooler) comes standard with a diode array tester and sample cooling | ||||
Main unit |
host |
|||
1 |
228-45202-58 includes |
LC-2030C 3D (Main unit) PDA with Cooler |
1 |
set |
Pump unit, 泵 |
||||
Degasser unit, Degassing machine |
||||
Low pressure gridient unit, Low pressure gradient unit |
||||
Mixer, mixer |
||||
PDA detector, Diode array detector |
||||
Column oven , column oven |
||||
Auto sampler with sample cooler, |
||||
2 |
228-45222-46 |
Accessory kit for LC-2030C 3D |
1 |
set |
3 |
228-57647-41 |
Tool Kit toolkit |
1 |
set |
4 |
228-38583-42 |
1 L Phase Bottle (5 pcs) Mobile phase bottle (1L, pack of 5) |
1 |
pc |
5 |
228-15652-92 |
1.5 mL Sample Vial 1.5 mL Sample Bottle (Glass, 100pcs, w/cap, silicone rubber septum) (Glass, 100 pieces, including bottle cap, silicone rubber spacer) |
1 |
pkg |
Workststion |
workstation |
|||
6 |
465-06266-93 |
LabSolutions LC Workstation Ver.5 Multi LC-PDA (Chinese version) |
1 |
pc |
Packed columns |
chromatographic column |
|||
7 |
5020-07346 |
InertSustain C18 5um 4.6 x 250mm, chromatographic column |
1 |
pc |
8 |
5020-19049 |
InertSustain C18 5um 2 CARTRIDGES, 4.0mm I.D.(2pcs/pkg), Protection column core (2/pack) |
1 |
pc |
9 |
5020-08500 |
Guard Column HOLDER for 10mm length , Protective column sleeve (4.0mm I. D column) |
1 |
pc |
7 |
5020-07345 |
InertSustain C18 5um 4.6 x 150mm, chromatographic column |
1 |
pc |
7 |
5020-07346 |
InertSustain C18 5um 4.6 x 250mm, chromatographic column |
1 |
pc |
8 |
5020-19049 |
InertSustain C18 5um 2 CARTRIDGES, 4.0mm I.D.(2pcs/pkg), Protection column core (2/pack) |
1 |
pc |
9 |
5020-08500 |
Guard Column HOLDER for 10mm length , Protective column sleeve (4.0mm I. D column) |
1 |
pc |