The T6 spectrophotometer uses a light source that can generate multiple wavelengths. Through a series of spectroscopic devices, a specific wavelength light source is generated. After the light source passes through the tested sample, some of the light sources are absorbed, and the absorbance value of the sample is calculated, which is then converted into the concentration of the sample.
T6 spectrophotometerUsing a light source that can generate multiple wavelengths, a series of spectral devices are used to produce light sources of specific wavelengths. After the light source passes through the tested sample, some of the light sources are absorbed, and the absorbance value of the sample is calculated, which is then converted into the concentration of the sample.
Characteristics of T6 spectrophotometer:
1. Excellent stability: excellent material selection, stable and durable;
2. Flexible scalability: hardware is easy to disassemble, software is flexible to upgrade;
3. Humanized overall design: high degree of automation, easy maintenance;
4. Functional analysis software: customizable measurement software packages for various industries;
5. Widely applicable fields: meeting the needs of health and epidemic prevention, teaching and research, environmental monitoring, agriculture, forestry, manufacturing, municipal agencies, scientific research institutions, survey and water conservancy, petrochemical industry and many other fields.
T6 spectrophotometer product functions:
● Luminescence measurement: convenient for measuring the absorbance, transmittance, and concentration of samples at wavelengths.
Quantitative measurement: Automatically establish standard curves, fit first-order/first-order zero crossing, second-order, and third-order curves, and select multiple quantitative analysis methods. Standard curves can be stored and called.
Qualitative measurement: Support continuous recording of 100 data points and automatically locate the wavelength position of the large absorption peak.
Dynamics measurement: Enzyme kinetics reaction rate calculation.
● Multi wavelength measurement: Supports data measurement of up to 10 wavelength points.
Precautions for using T6 spectrophotometer:
1) If the test wavelength is significantly changed, wait for a moment and recalibrate the "0" and "100%" points after the lamp reaches thermal equilibrium. Then measure again.
2) When the pointer type instrument is not powered on, the pointer of the electric meter must be at the zero mark. If this is not the case, mechanical zeroing is required.
3) After using the colorimetric dish, please rinse it immediately with distilled water and wipe off any water stains with a clean and soft cloth to prevent damage to the surface finish and affect the transmittance of the colorimetric dish.
4) Operators should not easily manipulate light bulbs and reflector lights to avoid affecting light efficiency.