Shandong Salt Spray Test ChamberNanjing Annai Testing Equipment Co., Ltd. has sufficient supply of goods. Style: tower, vertical, box, split, desktop, multifunctional, intelligent, microcomputer, customized according to customer needs!
Shandong Salt Spray Test ChamberThe functions and applications of can be summarized as follows: 1 The main purpose is to simulate salt spray corrosion conditions in marine or industrial environments; 2. The core function is to test the corrosion resistance of materials or coatings; 3. Achieve testing objectives by accurately controlling parameters such as temperature and salt spray concentration; 4. The core value lies in evaluating the durability performance of products in harsh environments; 5. Typical application areas include quality inspection in industries such as metal products, automotive parts, and electronic components.
Shandong Salt Spray Test Chamber,Ensure that the power supply for the salt spray test chamber and air compressor is connected, and connect the air compressor air pipe.

Shandong Salt Spray Test Chamber,Add purified water or distilled water to the inlet inside and behind the test chamber until the low water level light on the panel goes out, otherwise the equipment will not work properly.
Shandong Salt Spray Test Chamber,Complete the connection between the drainage pipe and exhaust pipe, ensuring that the indication to the left is in the open state.
Shandong Salt Spray Test Chamber,Add water to the isolation sink to the pad position to prevent salt spray leakage.
Shandong Salt Spray Test Chamber,Pour salt water into the salt solution replenishing bottle, and the equipment will automatically fill the salt water into the spray tower, so that the liquid medicine flows to the salt water spray tower.
6. Add water to the wet bulb cup and cover the wet bulb thermometer with gauze. Place the end of the gauze inside the wet bulb cup.
7. Place the test piece or specimen on the shelf and arrange it at an angle according to the standard regulations. For example, the standard test piece 130 × 70 (mm) can be tilted at 15 or 30 degrees.
8. Set the test temperature according to the required standards and use the button "▲" to increase or "▼" to decrease.
9. Set the test time within the range of 0-999 hours (H: hours; Press the "+" button to increase; Press the "-" button to decrease.
10. Press the power button and operate the button to preheat until the set temperature is reached. Attention: The test cover should be covered and handled with care to avoid damage.
After the experiment is completed, turn off all switches in order.