E-mail
1277926230@qq.com
-
Phone
13181278603
-
Address
Fuyuan 6th Road, Thailand Industrial Park, High tech Zone, Zaozhuang City, Shandong Province
Shandong Jinpu Analytical Instrument Co., Ltd
1277926230@qq.com
13181278603
Fuyuan 6th Road, Thailand Industrial Park, High tech Zone, Zaozhuang City, Shandong Province
OneShandong Jinpu OG-3000 Rock Pyrolysis InstrumentPrinciple:
The pyrolysis furnace heats rock samples under programmed heating conditions, and the three peaks S0, S1, S2, and Tmax (or five peaks S0, S1, S21, S22, S23) are quantitatively detected by FID. During pyrolysis, carbon dioxide is detected by an infrared detector for S3 (organic and mineral carbon monoxide S3CO and S3 ˊ CO, organic and mineral carbon dioxide S3 and S3 ˊ are detected separately). After pyrolysis, the residual carbon in the sample is heated by an oxidation furnace and detected by an infrared detector for residual organic carbon S4 and residual mineral carbon S5, thereby calculating the total organic carbon TOC and mineral carbon content MinC in the sample.
IIShandong Jinpu OG-3000 Rock Pyrolysis InstrumentMain performance characteristics:
1. The maximum furnace temperature for pyrolysis and oxidation is 850 ℃, which can accurately determine the Tmax value at higher temperatures.
2. The various pressure and flow parameters of the gas path are automatically measured, displayed, and controlled (optional for users).
3. The working status and analysis results of the instrument can be transmitted through Bluetooth or network.
4. In addition to detecting analysis parameters such as S0, S1, S2, S4, Tmax, it can also detect S3 and S5 and provide TOC (total organic carbon) and Min C (mineral carbon) measurement results.
5. Configure an automatic sampler with no less than 50 bits (optional for users).
6. It has a user-defined cycle (up to 10 program heating stages can be set), which can meet the analysis experiments of various situations such as source rocks, reservoir rocks, coal, oil shale, and hydrocarbon generation kinetics.
3、 Main technical parameters:
1. FID detector
1.1 Minimum detectable amount of hydrocarbons: 0.001mg hydrocarbons per gram of rock
1.2 Baseline drift:<0.1mv/30min
1.3 Linear range: 106
2. IR infrared detector
2.1 Range: (0-100)%
2.2 Linear error ≤± 1% F.S
2.3 Repeatability<1%
2.4 Zero drift ≤± 2% F.S/24h
3. Temperature controller
3.1 FID temperature control accuracy: 360 ± 0.5 ℃
3.2 Temperature control accuracy of pyrolysis furnace: 90-850 ± 0.5 ℃ (temperature can be set)
3.3 Temperature control accuracy of oxidation furnace: 100-850 ± 0.5 ℃ (temperature can be set)
Product size: 60 * 60 * 80
Weight: 50kg