15th Floor, Building 6, Courtyard 2, Wuliqiao Second Street, Chaoyang District, Beijing
Sensor self-monitoring function, indicating glass damage
A sturdy mechanical casing effectively protects the glass electrode
Replacing the glass electrode is very easy
Movable correction
SensoLyt®Design concept of series sensors
Continuous online monitoring during sewage treatment processpHVery strict requirements have been placed on instruments and sensors, and a reliable operating system must meet the following requirements: the structure must be sturdy and durable, and the testing must be stable, safe, and reliable.
WTWSpecially developed for the harsh environment of online monitoring of sewage treatmentSensorLytSeries sensors, a complete set of sensors includes an immersion type sturdy sheath with preamplifier and glass sensing electrodes. Paired with our high-quality monitoring devices, we can create a perfect setpHThe monitoring system has unparalleled high precision and reliability, as well as excellent performanceEMCElectromagnetic protection.
SensoLyt ® 700 IQAs a standard digital sensor, it can be connected toIQ Sensor NetIn the middle. Standard components include built-in preamplifier and stainless steel built-inNTCTemperature probe. giveWTWofIQUsed in conjunction with the host, the internal special circuit will automatically detect electrode damage. Has standard lightning protection features. It has the function of automatically storing calibration data, so users can fully calibrate the sensor in the laboratory and then connect it back to the site.
SensoLyt ®sensor assembly
•Pre amplification function of electrode signal
•installNTCTemperature sensors are used for temperature measurement
•Protect the glass electrode to prevent mechanical damage
•Save calibration data
come frompH/ORPThe high impedance and low voltage signals of electrodes are highly susceptible to noise and ground current interference. For this reason,WTWBuilt in a preamplifier in the sensor component to amplify and convert the signal into low impedance, so that the signal can be transmitted over long distances, such as when requiredIn situations where transmitters are installed remotely.
SensoLyt ®The sensor component is built-in with oneNTCTemperature sensor, used for temperature measurement and automatic temperature compensation. This enables simultaneous measurement in one probepHperhapsORPAnd the temperature value. Under harsh industrial operating conditions, the sturdy casing ispH/ORPGlass electrodes provide important mechanical protection. For service purposes, glass electrodes can be replaced on-site without the need for any tools.
|
|
SensoLyt®SEA High temperature and high pressure resistancepHComposite electrode, with2A pinhole shaped diaphragm, electrolyte is a solid polymer, not affected byAgClInterference, therefore resistant to interference, suitable for municipal and industrial wastewater with severe pollution. Test scope:pH 2-12 · Severely polluted sewage · Suspension, emulsion · Containing protein andS2-The medium
SensoLyt®PtA Design and electrochemical characteristicsSensoLyt ® SEASame, justPtAIt's compositeORPElectrode, with2A pinhole shaped diaphragm is recommended for use in severely polluted wastewater. Test scope:±2000 mV · Municipal and industrial wastewater · Suspension, emulsion · Containing protein andS2-The medium |
SensoLyt®SEA-HP Resistant to higher pressurepHComposite electrode Test scope:pH 4-12 · Pipeline installation
SensoLyt®DWA Long service life, more accurate testing, suitable for low conductivity applications such as drinking water. Test scope:pH 0-14 · drinking water
SensoLyt®ECA Economic typepHComposite electrode, with1A pinhole shaped membrane, gel electrolyte. More commonly used in sewage monitoring. Test scope:pH 2-12 · Ordinary sewage
|
During operation, the electrode slope and zero point potential will gradually change over time. Calibration is to test the current slope and zero point potential of the electrode. Calibrate before testing and calibrate at fixed intervals (depending on the application). There are various calibration methods available, including:
CAL TEC AUTOautomaticCorrection: AdoptingWTWFully automatic calibration of standard solution.
CAL CON 2PTwo pointsCorrection: Traditional using any standard solution2Point calibration mode.
CAL CON 1Psingle-pointCorrection: Traditional method using a single standard solution1Point calibration mode.
The calibration records include current and last calibration records, and users can access the calibration history to view the calibration records.
Correction evaluation
After system calibration, the calibration data and the current status of the sensor are automatically evaluated, with zero drift and slope evaluated separately. The data must be within the following range. If one of the two data exceeds a specific range, calibration is unsuccessful and the sensor must be maintained.
Slope:-50 . .. -62 mV/pH
zero point:-45 mV ... +45 mV
structure
External dimensions
Technical Parameter
|
model |
SensoLyt ® 700 IQ(SW*) |
||
|
measuring principle |
Use a composite electrode for potential measurement;Built in microprocessor, two core shielded cable containing power and data transmission |
||
|
measuring range |
Measurement unit |
measuring range |
resolution |
|
pH |
0.00 . .. 14.00 pH (Depends on the electrode) |
0.01 pH |
|
|
ORP |
-2000 mV ... +2000 mV |
1 mV |
|
|
temperature measurement |
Built in temperature sensor |
NTC |
|
|
measuring range |
- 5 °C ... + 60 °C |
||
|
accuracy |
± 0.5 K |
||
|
resolution |
0.1 K |
||
|
reaction timet99 |
< 15 s |
||
|
temperature compensation |
0 °C ... + 60 °C |
||
|
Electrode inspection |
detectionPHIs the electrode glass damaged |
||
|
Store calibration data |
have |
||
|
Applicable electrodes |
SEA、GDA、ECA、PtA |
||
|
Surrounding environment |
Working temperature:0 … 60℃Storage temperature:-5 … 65℃ |
||
|
material |
Electrode tip:PVC,Electrode rod:316Tistainless steel,Protection level:IP 68 |
||
|
pressure resistance |
10Ba (including sensor connection cable) |
||
|
Insertion depth |
small40cm, Big100m |
||
|
Flow rate requirements |
No flow rate requirements |
||
|
Lightning protection |
Built in lightning protection circuit |
||
|
EMI/RFI |
conform toEN61326 Class B, FCC Class AStandard regulations |
||
|
authentication |
CE, cETLus |
||
|
power consumption |
0.2tile |
||
|
size |
508×40 mm, L×D 515×59.5 mm, LXD(SW) |
||
|
weight(Excluding cables) |
make an appointment970g, SWmake an appointment1800g |
||
SensoLyt ®Series glass composite electrode
|
model |
SEA |
SEA-HP |
DWA |
ECA |
PtA |
|
type |
Colloidal solid polymer electrolyte 2A pinhole shaped diaphragm |
Improved gel electrolyte, pinhole diaphragm |
Gel electrolyte,1A pinhole diaphragm |
Gelatinous solid electrolyte,Needle like diaphragm |
|
|
temperature resistance/pressure resistance |
10hope earnestly/20℃ |
10hope earnestly/20℃ |
6hope earnestly/20℃ |
6hope earnestly/20℃ |
10hope earnestly/20℃ |
|
Range |
2 … 12 pH |
4 … 12 pH |
0… 14 pH |
2 … 12 pH |
± 2000 mV |
|
Mechanical Construction |
Cylindrical glass sensing film,PVCsheath(SEA-HPdoPOM), |
||||
|
size |
long120 mm(Excluding top threaded joint) |
||||
|
joint |
S8Thread Joint |
||||
|
Ordering information for pH/ORP sensors |
||
|
model |
describe |
order No |
|
SensoLyt ® 700 IQ |
IQdigitpH/ORPSensor component, built-in preamplifier |
109170 |
|
SensoLyt ® 700 IQ SW |
Used for seawaterIQdigitpH/ORPSensor component, built-in preamplifier |
109171 |
|
SensoLyt ® 700 IQ/SET |
IQdigitpHsensor assemblysuit, |
109173 |
|
SensoLyt ® 700 IQ/SET1 |
IQdigitORPsensor assemblysuit, |
109174 |
|
SACIQ-7.0 |
IQSpecial cable |
480042 |
|
SensoLyt ® SEA |
pHComposite electrode,2…12 pH |
109115 |
|
SensoLyt ® SEA-HP |
pHComposite electrode,4…12 pH |
109118 |
|
SensoLyt ® DWA |
pHComposite electrode,0…14 pH |
109119 |
|
SensoLyt ® ECA |
pHComposite electrode,2…12 pH |
109117 |
|
SensoLyt ® PtA |
ORPComposite electrode,± 2000 mV |
109125 |
processpHelectrodeProcessLine
-Used for measurementpHProcess detection of temperature and oxidation-reduction potential using high-temperature and high-voltage electrodes
From the perspectives of accuracy, stability, rapid response, and long service life, professionally manufacturedProcessLineElectrodes that are almost equivalent in performance to liquid electrolytes
Maintenance saving, which means no need to add electrolyte and installation without complex pressure sequence control
Pinhole diaphragm to prevent contamination or scaling of the reference electrode
DuralidelectrolyteKClHigh content and special performance, ensuring a long service life and fast and stable measurement results
Verified through practiceHMembrane glass with extremely low sodium difference and perfectly spherical shape
It has a wider range of applications and can be used in media or solvents with extreme ionic strength, strong oxidants, strong acids, and strong bases.
Based on the above factors,ProcessLineElectrode maintenance is very cost-effective and efficient, making it the preferred product in complex process areas, especially in the known chemical industry
Technical Parameter
|
model |
PL 80-225 pH |
PL 81-225 pHT VP |
PL 82-225 pHT VP |
PL 89-225 Pt |
|
measuring range |
0 - 14 |
0 - 14 |
0 - 14 |
0 - 14 |
|
temperature range |
0 – 130℃ |
0 – 130℃ |
0 – 130℃ |
0 – 130℃ |
|
temperature sensor |
- |
Pt 1000 |
Pt 100 |
- |
|
joint |
S7Plug,PG13.5 |
VPplug |
VPplug |
S7Plug,PG13.5 |
|
reference system |
DuralidGel electrolyte, low maintenance,Ag/AgClsystem |
|||
|
membrane |
Double hole |
|||
|
pressure |
12bar |
|||