Selection of manufacturers for sewage flow meters

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Why is it called sewage flowmeter manufacturer selection? Because this flowmeter can be used to measure sewage flow. The sewage flow meter is a sewage electromagnetic flow meter. Currently, there is a customer demand for this in the market, so we will introduce it as a separate product. The $r $n-LDE-D sewage flowmeter is composed of the - LDE-W sewage electromagnetic flowmeter sensor and the SC-LDE-S sewage electromagnetic flowmeter converter. It is an instrument used to measure the volumetric flow rate of various conductive liquids in pipelines and channels.

Product Details

Why is it calledSelection of manufacturers for sewage flow metersBecause this flowmeter can be used to measure sewage flow rate. The sewage flow meter is a sewage electromagnetic flow meter. Currently, there is a customer demand for this in the market, so we will introduce it as a separate product.
-The LDE-D sewage flowmeter is composed of the LDE-W sewage electromagnetic flowmeter sensor and the SC-LDE-S sewage electromagnetic flowmeter converter. It is an instrument used to measure the volumetric flow rate of various conductive liquids in pipelines and channels.

-LDE-D type

Selection of manufacturers for sewage flow metersIt can be widely used for measuring the volumetric flow rate of conductive liquids in municipal water supply, steel, petroleum, chemical, power, industry, water conservancy, water resources and other departments, especially suitable for flow measurement in channels, small rivers, and sewage measurement in environmental protection treatment.
Principle of sewage flowmeter:

The measurement principle of sewage flowmeter is based on Faraday's law of electromagnetic induction. The measuring tube of the flowmeter is a short tube lined with insulating material and non-magnetic alloy. Two electrodes are fixed on the measuring tube along the diameter of the tube, passing through the wall. The electrode tip is completely flush with the inner and outer surfaces of the lining. When the excitation coil is magnetized by bidirectional square wave pulses, a task magnetic field with a magnetic flux density of B will occur in a direction perpendicular to the axis of the measuring tube. At this point, if a liquid with a certain conductivity flows through the measuring tube, it will cut the magnetic field lines and induce an electromotive force E. The electromotive force E is proportional to the magnetic flux density B. Measure the product of the inner diameter d of the tube and the uniform flow velocity V. The electromotive force E (flow signal) is detected by the electrode and sent to the converter through the cable. After enlarging the flow signal, the converter can display fluid flow and output pulse, analog current and other signal signals for flow control and regulation.

2、 Characteristics of sewage electromagnetic flowmeter:

Small size, light weight, easy installation, and low maintenance required
Wide measurement range, measurement is not affected by changes in fluid temperature, density, pressure, viscosity, conductivity, etc
Can be modified and installed by drilling holes on old pipelines, with simple construction and installation, and a small amount of work
Compared to general electromagnetic flow meters, it has lower costs and installation expenses, making it particularly suitable for measuring flow in large and medium-sized pipelines
Adopting advanced processing techniques, solid-state packaging, long lifespan, and ensuring good measurement accuracy and stability of the instrument
Simple structure, sturdy and reliable, long service life (and suitable for measuring seawater)
There are no moving parts or resistance parts inside the measuring tube, no pressure loss, and no blockage will occur
Reliable measurement and strong anti-interference ability
3、 Main technical performance indicators of sewage flowmeter:
Flow velocity measurement range: (0.05-10) m/s
Power consumption:<15VA
Protection level: IP68
Connection method: flange connection
Electrode materials: molybdenum containing stainless steel OCr18Ni12Mo2Ti, Hastelloy B, Hastelloy C, titanium Ti, tantalum, etc
Measuring pipeline diameter: DN (32-6000) mm
Instrument accuracy: Level 1.0
Work pressure: ≤ 1.6MPa
Medium temperature: 0-80 ℃
4、 Installation requirements for sewage flow meters:
1) In terms of installation environment:
It is advisable to stay away from equipment with strong electromagnetic fields, such as large motors, transformers, and frequency converters.
The installation site should not have strong vibrations, the pipeline should be securely fixed, and the ambient temperature should not change significantly (to prevent solid-liquid two-phase changes).
The installation environment should be easy to install and maintain.
2) In terms of installation location:
The installation position must ensure that the pipeline is always filled with the measured liquid.
Choose a location with low liquid flow pulses, which should be away from local resistance components such as pumps, valves, and elbows.
When measuring biphasic (solid, liquid, gas, liquid) liquids, a location that is not prone to phase separation should be selected.
The inner diameter or circumference of the tested pipeline should be easy to measure, and the ellipticity should be small.
3) In terms of the length of the straight pipe section:
The length of the straight pipe section on the upstream side of the sensor installation pipeline should be greater than or equal to 10D, and the downstream side should not be less than 5D (D is the diameter of the measured pipeline).
4) Regarding flow control valves and regulating valves:
The flow control valve should be installed in the measured pipeline upstream of the sensor, and the flow control valve should be installed downstream of the sensor.
When it comes to flow, the flow control valve should usually be fully open.

6、 Selection of electrode materials for sewage flowmeter:

material corrosion resistance
316L For nitric acid, sulfuric acid at room temperature<5%, boiling phosphoric acid, alkaline solution; Under certain pressure, media such as sulfurous acid, seawater, and acetic acid have strong corrosion resistance.
Hastelloy HB Resistant to all concentrations of non oxidizing acids, bases, and non chlorinated hydrochloric acids such as hydrochloric acid, sulfuric acid, hydrofluoric acid, and organic acids at boiling point.
Hastelloy HC Resistant to oxidizing acids such as nitric acid, mixed acids, or mixtures of chromic acid and sulfuric acid, as well as oxidizing salts and seawater
Titanium It can withstand corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming nitric acid), organic acids, alkalis, etc. It is not resistant to corrosion from relatively pure reducing acids (sulfuric acid, hydrochloric acid), but corrosion is greatly reduced when the acid contains oxidants (such as nitric acid and media containing Fe and Cu ions).
Tantalum It has excellent corrosion resistance similar to glass, except for hydrofluoric acid and concentrated sulfuric acid, and can withstand corrosion from almost all chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 175 ° C). It is not resistant to corrosion in alkali.

7、 Selection of Diameter and Flow Rate for Sewage Flow Meter

Nominal diameter (mm) Measurable flow range (m3/h) Effective measurement flow range (m3/h) Nominal diameter (mm) Measurable flow range (m3/h) Effective measurement flow range (m3/h)
4 0.0135~0.4522 0.0135~0.4522 250 8.8313~2119 52.9875~1766
6 0.0305~1.0173 0.0305~1.0173 300 12.717~3052 76.302~2543
8 0.0543~1.8086 0.0543~1.8086 350 17.31~4154 103.86~3461
10 0.0142~3.3912 0.0848~2.826 400 22.61~5425 135.65~4521
15 0.0318~7.6302 0.1908~6.3585 450 28.62~6867 171.68~5722
20 0.0566~13.5648 0.3392~11.304 500 35.33~8478 211.95~7065
25 0.0883~21.195 0.5298~17.6625 600 50.87~12208 305.2~10173
32 0.1447~34.7258 0.8682~29.9382 700 69.24~16616 415.4~13847
40 0.2261~54.2592 1.3565~45.216 800 90.44~21703 542.6~18086
50 0.3533~84.78 2.1195~70.65 900 114.46~27468 686.7~22890
65 0.5970~143.28 3.5819~119.39 1000 141.3~33912 847.8~28260
80 0.9044~217.03 5.4259~180.86 1200 203.5~48833 1221~40694
100 1.413 ~339.12 8.478~282.6 1400 277~66467 1662~55389
125 2.2079~529.87 13.2468~441.56 1600 361.8~86814 2171~72345
150 3.1793~763 19.0755~635.85 1800 457.9~109874 2747~91562
200 5.652~1356 33.912~1130.4