Second hand Younike ethylene oxide sterilization cabinet on duty

NegotiableUpdate on 05/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The second-hand Younike ethylene oxide sterilization cabinet is used to recycle various Younike ethylene oxide sterilization cabinets. The ethylene oxide does not damage the sterilized items and has strong penetration, so most items that are not suitable for general sterilization methods can be disinfected and sterilized with ethylene oxide. For example, electronic instruments, optical instruments, medical devices, books, documents, fur, cotton, synthetic fibers, plastic products, wooden products, ceramics and metal products, endoscopes, and disposable medical supplies

Product Details

Second hand Younike ethylene oxide sterilization cabinet on duty

What precautions should be taken for daily sterilization of ethylene oxide sterilization cabinets


During the daily sterilization process, the ethylene oxide sterilization cabinet needs to pay attention to the following items to ensure sterilization effectiveness, operational safety, and personnel health:

1、 Preparation before sterilization

  1. Item cleaning: Items to be sterilized must be thoroughly cleaned to remove surface dirt, blood stains, tissue and other impurities. Avoid using physiological saline for cleaning and ensure that there are no water droplets or excessive water on the items to prevent dilution and hydrolysis of ethylene oxide. For medical devices, specialized cleaning agents should be used for cleaning, followed by drying in a drying oven or compressed air.

  2. Equipment inspection: Check whether the sterilization equipment is operating normally, including whether the electric or steam valve, circulation valve, vacuum pump, dosing valve, vent valve, etc. are closed, and whether the printing paper, sterilizer door, touch screen, etc. are functioning properly. At the same time, check whether the normal operation, temperature, humidity and other parameters of the equipment meet the requirements, and whether the ethylene oxide gas is sufficient.

  3. Personal protection: Ethylene oxide is a toxic gas, so operators should wear protective equipment such as masks, gloves, goggles, etc. to avoid direct contact.

2、 Sterilization operation

  1. Packaging and loading: Sterilized items should be placed in suitable packaging bags and ensure that the packaging is intact. Use a dedicated sterilization basket to load the items to be sterilized, and check their packaging quality and information. During the loading process, there should be a certain gap between the sterilization packages, and the paper and plastic packaging items should be placed on the side to avoid overlapping or squeezing, in order to ensure that the ethylene oxide can penetrate evenly to the surface of each instrument.

  2. Sterilization process: Strictly follow the confirmed sterilization process, keep complete records, and ensure the sterilization effect of the product. The selection of parameters including ethylene oxide concentration, temperature, humidity, pressure, and time should be adjusted reasonably based on the characteristics of the sterilized item.

  3. Monitoring and indication: Biological indicators must be placed during each sterilization cycle to monitor the sterilization effect. At the same time, monitoring methods such as chemical indicator cards are used to ensure that parameters such as temperature, pressure, and time during the sterilization process meet the requirements.

Second hand Younike ethylene oxide sterilization cabinet on duty