Product Usage
◆Salt spray corrosion test chambersuitSalt spray corrosion protection for components, electronic parts, metal materials, and industrial productssexexperiment
box structure
◆The overall molding is welded at high temperature, corrosion-resistant, easy to clean, and leak free
◆tower typeOr baffle typeSpray system, salt liquid filtration system, no crystallization nozzle, uniform distribution of salt spray, free adjustment of sedimentation
◆The box cover adoptsPPmaterial, Visual WindowThe test items and spray conditions in the box can be clearly seen
◆A water sealed structure is used between the box cover and the box body to prevent salt spray from overflowing
◆The circuit control board and other components are fixed in positions that are easy to inspect and maintain, using door lock opening edge cover doors, which not only Beautiful and easy to maintain
control system
◆High precision digital temperature controller, imported from South KoreaThree element ST140, precise and stable control, long-term operation without drift
◆Continuous or periodic spray optional,Alternating (composite) salt spray can be used for testing the alternating changes of salt spray, wet heat, immersion, and drying cycles
◆Schneider Electric components, domestic high-quality accessories selection
◆Multiple system protections such as overheating protection device, low water level alarm, timing alarm, etc. ensure safe use
meet the standard
Strictly follow:GB/T2423.17-2008、GB/T10587-2006、GJB150.9-86、GJB150.11-86、GB/T10125-1997、GB/T5170.8-1996、DIN50021、ISO1456-74、ISO3768-78、ASTM B117-73 Design and manufacture experimental methods
Specifications and Technical Parameters
| model | YWX-150(B) | YWX-250(B) | YWX-750(B) | YWX-010(B) | YWX-020(B) | ||||||||
| insideformsizeD×W×H mm | 450×600×400 | 600×900×500 | 750×1100×500 | 850×1300×600 | 900×2000×600 | ||||||||
|
technologyindicator | temperature range | RT+5℃~55℃ 0℃~75℃ | |||||||||||
| Temperature Uniformity | ≤±2.0℃ | ||||||||||||
| temperature fluctuation | ≤±0.5℃ | ||||||||||||
| humidity range | >98%R.H 50%~98% 30%~98% | ||||||||||||
| salt spray deposition | 1~2ml/80cm2.h | ||||||||||||
| Spray mode | Airflow spray, continuous spray and intermittent spray can be adjusted and set | ||||||||||||
| experimenttime | Adjustable from 0 to 9999 (S, M, H) | ||||||||||||
|
Temperature and humidity operation control system | temperature control | LED digital display P.I.D+S.S.R microcomputer integrated controller/Touch screen program control | |||||||||||
| temperature sensor | Platinum resistance.PT100Ω/MV | ||||||||||||
| heating system | Fully independent system、Nickel chromium alloy electric heating heater | ||||||||||||
| spray system | tower typeOr baffle typeSpray device with non crystallization nozzle (finer and evenly distributed particles) | ||||||||||||
| Spray time | 0~9999 (S, M, H) and adjustable cycle | ||||||||||||
| Humidity inside the boxcontrol | Bottom sink for moisture supply External boiler for moisture supply | ||||||||||||
| Salt collection | Equipped with standard funnel and standard measuring cylinder | ||||||||||||
| Salt liquid filtration | Install a water quality filter at the suction tube to prevent nozzle blockageButTerminate the experiment) | ||||||||||||
| Preheating of salt solution | The temperature of the salt solution is balanced with the temperature inside the box (so that the low temperature of the salt solution does not affect the test temperature) | ||||||||||||
|
Materials used
| Box material | adoptImported corrosion resistance, aging resistance and high strengthPPboard | |||||||||||
| Inner box material | adoptImported corrosion-resistant and high-strengthPP、Imported corrosion resistance, high strength, aging resistance and high temperature resistancePP board | ||||||||||||
| Box cover material | adoptImported corrosion-resistant and high-strengthPP board/Imported corrosion-resistant, high-strength, and high-temperature resistantPP flame retardantboard | ||||||||||||
| other attachments | All are made of stainless steel, copper, or materials that are corrosion-resistant and heat-resistant | ||||||||||||
| Standard Configuration | Round rod1 V-shaped sample rack eachdeputy, nozzle2 pieces, funnel, measuring cylinder 2 sets | ||||||||||||
| safety protection | Leakage, short circuit, overheating, water shortage, end of test, overcurrent protection | ||||||||||||
| Total power | 1.5KW | 2.0KW | 2.5KW | 3.5KW | 6.5KW | ||||||||
| power supply voltage | AC220V±10% 50Hz | AC380V±10% 50Hz | |||||||||||
| Total power of alternating salt spray | 3.5KW | 4.5KW | 6.5KW | 8.5KW | 14.5KW | ||||||||
| power supply voltage | AC380V±10% 50Hz | ||||||||||||
| Environmental temperature for use | 5℃~+30℃ ≤85%R. H | ||||||||||||
| seal | Adopting a water sealed structure, there is no salt spray overflow | ||||||||||||
| Extended products | damp-heatSalt spray corrosion test chamberAlternatingSalt spray corrosion test chamberCompliant with alternating currentSalt spray corrosion test chamberModificationSalt spray corrosion test chamberSalt water immersion test chamber, salt spray+Corrosion gas test chamber, etc | ||||||||||||
| Note: New typeSalt spray corrosion test chamberIts energy-saving and consumption reducing performance is superior to similar domestic products(50%) | |||||||||||||
| This test box meets the requirementsGB/T GJB、And equivalentIEC, MIL, DIN, ASTM and other relevant standards | |||||||||||||
| This technical information is subject to any changesexcusenoto be notified separately | |||||||||||||