Salt spray comprehensive testing box for contact network componentspurpose
The salt water spray tester is used to test the corrosion resistance of the products after the surface of various materials has undergone corrosion treatment such as electroplating, anodizing, spraying, and antirust oilSalt water spray tester can GB-T2423.18-2000、GB-T6461-2002、ASTM.B117-2009、JIS H8502、IEC 60068-2-11-1981 Developing corrosion resistance for metal components and coatings
Sex.
2) Main components/functional requirements of the equipment
The saline spray tester is mainly composed of power distribution control cabinet, heating system, water make-up system, drainage system, spray system, air supply system, mist exhaust system, electrical control system, safety protection device, etc.
3) Main technical parameters
Temperature range of test chamber: 0 ℃ -70 ℃
Meet the standards: GB-T2423.18-2000、GB-T6461-2002、ASTM.B117-2009、TIS H8502、IEC 60068-2-11-1981
Nominal internal volume 800L
The reference size of the inner box is 1600x500x1000mm (length * width * height)
Power supply conditions and AC 380V three-phase R, S, T, N+protective grounding; The allowable voltage fluctuation range is 10% V;
The allowable frequency fluctuation range is 50 ± 0.5HZ; TN-S power supply or TT power supply
The grounding resistance of the protective grounding wire is less than 4 Ω
Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must independently control the use of the equipment
Salt spray comprehensive testing box for contact network componentsperformance metrics
The values measured under the environmental conditions of+25 ℃, relative humidity ≤ 85%, and no sample in the test chamber.
Laboratory temperature: Saltwater test method (NSS CASS) 35 ℃± 1 ℃/Corrosion resistance test method (CASS) 50 ℃± 1 ℃
Pressure bucket temperature: Salt water test method (NSS CASS) 47 ℃± 1 ℃/Corrosion resistance test method (CASS) 63 ℃± 1 ℃
Salt water temperature: 35 ℃± 1 ℃, 50 ℃± 1 ℃
Laboratory capacity: 800L
Salt water tank capacity: 40L
Salt water concentration: Add 0.26 grams of copper chloride per liter to a concentration of 5% sodium chloride solution or 5% sodium chloride solution
Compressed air pressure: 1.00 ± 0.01kgf/cm2
Spray volume: 1.0~2.0ml/80 c ㎡/h
Laboratory relative humidity: above 85%
PH value: 6.5-7.2, 3.0-3.2
Spray mode: continuous spray