-
E-mail
sute@56412027.com
-
Phone
13818304481,13917842543
-
Address
508, Building 4, Lane 680, Shuishe West Road, Baoshan District, Shanghai
Shanghai Xuji Electric Co., Ltd
sute@56412027.com
13818304481,13917842543
508, Building 4, Lane 680, Shuishe West Road, Baoshan District, Shanghai

Due to the maximum application range of various low-voltage switchgear equipment in the power system, especially outdoor switches that operate in atmospheric environments and are exposed to weather conditions for a long time, the operating conditions are relatively harsh, and it is easy to cause mechanical and electrical failures. Especially, the contact contact part is corroded by the gas, which can lead to poor contact and heat generation. The contact pressure spring is annealed due to heat generation, resulting in a vicious cycle of contact heating and ultimately burning out the contacts, leading to accidents. During maintenance, only the obviously failed and broken contacts are often replaced, and the spring contacts with reduced pressure cannot be compared and replaced. Therefore, in long-term operation, the distribution of current in each contact will be different due to different pressures. The greater the difference, the more uneven the current distribution. Poor contact of one contact will affect the entire switch. The normal operation of the cabinet, Causing accidents to electrical equipment in operation.
The SMN series contact pressure detector uses 5V0 constant voltage excitation to power the 1-5K pressure sensing resistor bridge, and data is collected by an external 24 bit high-precision A/D under the same 5V0 reference. Select various measurement methods from the bilingual prompt software menu in both Chinese and English. After data processing, it is displayed on a high brightness green 12864 dot matrix active light-emitting OLED screen. And there is a buzzer reminder and dedicated green and red OK and OUT lights to indicate whether the output result is qualified or not. It is a specialized measuring instrument used to check whether the contact pressure of power equipment is qualified.
Instrument working mode:
Divided by settingsCalculate the contact pressure of the measurement display using three methods: "key measurement", "automatic", and "continuous".
Startup byCompare the comparison type and upper and lower limits of 24LC64 loaded into RAM to determine if the contact pressure is qualified.
If qualified, the buzzer will sound continuously0.5 seconds and the OK green light stays on, and the measurement value is displayed on the main screen.
If it is not qualified, the buzzer will beep three times rapidly and brieflyThe OUT red light is constantly on to sound an alarm, and the measurement value is also displayed on the main screen.
The main technical specifications of the SMN series contact pressure detector are:
Tension measurement(N) |
Charging time |
working hours |
|
0~200N |
shortest8 hours |
shortest8 hours |
scope |
1.0 % |
maximum12 hours |
maximum24 hours |
precision |

The working interface of the integrator includes five interfaces, the first screen is the main interface, and the second screen is the auxiliary interface.
The main screen interface is shown in Figure 1:

The measurement result is generated by pressing the test button or inserting the probe in automatic mode, and the result is displayed approximately every 3 seconds in continuous mode.
The zero point calibration of the second screen is shown in Figure 2:

When the test head is empty and not loaded, enter the password "10" to complete the on-site zero calibration and reset to 0.
The auxiliary interface of the third screen is shown in Figure 3:

Enter password“22”Or“33”You can enter the user or engineer menu separately.
After the power switch is turned on, the instrument first performs a self check and enters the screen after completion1The work master displays the status.
press “<” Key orSwitch between the main work screen 1 and the auxiliary work screens 2 and 3 with the "+" symbol.
pressAfter pressing the "Test" button, clear the screen values and results and turn off the traffic lights. Then, perform a set of sampling calculations and comparisons, and display the new measurement results after a delay of 0.5 seconds.
On the display screen3 status, text prompt "Enter password", use "S,+",◄,Enter the password using the "E" key combination.
E "key: Enter the initial password input state. S "key: Cancel input mode and return to the main screen display.
Press in input mode“+”Press the key to cycle through the values 0-9 and symbols at the cursor.
Press in input mode“<”Press the key to move the current input cursor position.
Press in input modePress the "E" key to bring up the cursor or confirm saving parameters.
If it is correct, enter the menu; if it is incorrect, return to the initial input state.
Zero point return0 Password: 10
User menu password: 22
Engineer menu password:33
The detector menu includes a user menu, an engineer menu, and a manufacturing menu. The engineer menu must be set by operators with professional knowledge. The production and manufacturing menu is calibrated by the factory when the detector is sent out. After leaving the factory, this type of parameter setting can only be modified under the corresponding equipment conditions, otherwise it will cause measurement errors or failure of the detector!
In the menu browsing, pressPress the "+" key to scroll down; Press“<”Flip up the key. Press the "S" key to return to the work screen 2 interface. In the submenu, press the "S" key to exit; Press the "E" key to enter the modification mode. If you want to modify the selection item in the modified state, press the "+" key to select downwards; Press“<”Select upwards and press the "E" key to confirm. If it is an input based modification, follow theInput operationconduct.
name call, name, say, weigh |
inside Rong |
prepare note |
|
|
fuck make, do, create, compose, write, etc. key |
S back button |
·When setting parameters, it is used to exit the menu step by step |
Return to the previous menu |
|
+ Set value increase key |
·When setting parameters, it is used to increase the current value of the cursor ·Switch display screen |
Short parameters can be directly modified, long parameters can be pressed firstE 。0 →1→…→9→.→0,Y→N→Y,+→-→+ |
|
|
◄ Shift key |
·Move the cursor left or right by one position ·Move right to increase the number of digits ·Switch display screen |
Move left to skip the decimal point and return to the right when reaching the left end of the numerical range |
|
|
E confirm button |
·Modify parameter settings ·When setting parameters, it is used to start inputting, confirming, and storing new parameter values |
Long parameter first pressAfter entering E, clear the parameter and start inputting. Press E again to input the value and store it in EEPROM. Return the cursor to the far right end |
|
Notes:
When setting parameters, the displayed content needs to be adjusted according toOnly after confirming with the "E" key can it be stored, otherwise the setting is invalid
|
Zero point return0 F=0:ADJ ZERO password: Password: XX |
On site school sensor0-point ADZ (Password)10) |
Enter passwordAt 10 o'clock, calibrate the current AD value to the zero point ADZ Enter passwordAt 90 o'clock, return to zero and clear to zero |
In the auxiliary interface password input state, enterThe password "22" enters the user menu, and the user menu structure is shown in the following figure,
The functions and parameter meanings of each menu are shown in the following table:
table 1User parameter setting menu (The password is22).
table 2 User menu structure and function description
|
submenu serial number |
Menu Display |
meaning |
Select option or numerical range |
1 |
measurement method Test-Mode Key testing KEY |
Measurement method selection (Default key test) |
Key testing/Automatic/Continuous KEY/AUTO/RUN Keytest: PressThe Test key completes one measurement. Automatic: From empty to probe insertion and stable completion of one measurement. Continuous: Continuously and continuously aboutMeasure every 3 seconds. |
2 |
buzzer Beep open ON |
Buzzer switch selection (default enabled) |
open/Close it ON/OFF |
In the menu, pressThe "E" key enters the selected parameter modification state. If it is a numeric input type parameter, enter the number through the "+" key, “<”Press the key to move the input cursor position, press the "E" key to confirm the input, and the detector will automatically update the setting parameters and store them; If the parameter is a selection type, use a "+" or“<”Flip up and down the selection options, select the content and press the "E" key to confirm. The transmitter will automatically update the setting parameters and store them.
In the auxiliary interface password input state, enterThe password '33' enters the engineer menu, and the structure of the engineer menu is shown in the following figure.
table 3. Structure and Function Description of Engineer Menu
|
menu serial number |
Menu Display |
meaning |
Select option or numerical range |
1 |
language Language Chinese/ENGLISH |
Choose language |
Chinese/ENGLISH |
2 |
Qualified method OK-Mode Greater than the lower limit F>min |
Qualified method selection (Default greater than lower limit) |
Greater than the lower limit/Less than upper limit, greater than lower limit/less than upper limit F>min/MAX>F>min/MAX>F |
3 |
Qualified upper limit OK-MAX N XXX.XX |
Set the upper limit of qualified touch force (Default)80.00) |
0-999.99
|
4 |
Qualified lower limit OK-min N XXX.XX |
Set the lower limit of qualified contact force (Default)40.00) |
0-999.99
|
In the menu, pressThe "E" key enters the selected parameter modification state. If it is a numeric input type parameter, enter the number through the "+" key, “<”Press the key to move the input cursor position, then press the "E" key to confirm the input. The transmitter will automatically update the setting parameters and store them; If the parameter is a selection type, use a "+" or“<”Flip up and down the selection options, select the content and press the "E" key to confirm. The transmitter will automatically update the setting parameters and store them.
The production calibration of instruments should be carried out by professionals with a deep understanding of instruments under the condition of calibration equipment with corresponding accuracy. At least there should be force application equipment with corresponding range, with accuracy better than0.1%The voltmeter. Without corresponding equipment and sufficient professional knowledge, improper calibration will result in the instrument not working properly. After confirming the password, you can enter the production settings state and set the corresponding instrument parameters.
In the auxiliary interface password input state, enterThe "96" password enters the production calibration menu, and the structure of the production calibration menu is shown in the following figure. The functions and parameter meanings of each menu are shown in the following table:
table 4. Structure and Function Description of Production Calibration Menu
serial number |
Menu Display |
meaning |
Select option or numerical range |
1 |
initialization Enter password XX |
Initialize parameters
|
Enter passwordAt 70 o'clock, EE is initially set as the program value Enter password79 Save EE parameters in 101F small page |
2 |
100% contact force value 100%Fmax= N XXX. XX |
Set the upper limit of touch force sensing (Default)200 cows) |
Enter passwordAt 90 o'clock, EE was restored to the factory 101F value
Usually refers to the full-scale value of instruments or sensors |
3 |
School Touch Power100% ADJ 100%Fmax AD=XXX save SAVE |
School contact force channel 100% point |
Press firstConfirm with E to display the sampled value, save/modify S does not store, E stores the value. +Or<replace withmodify CHANGE pressThe value can be changed after E; Press E again to save, S not to save |
4 |
75% contact force value 75%Fmax= N XXX. XX |
Set up touch force sensing75% value |
XXX.XX |
5 |
School Touch Power75% ADJ 75%Fmax AD=XXX save SAVE |
School contact force channel 75% points |
Press firstConfirm with E to display the sampled value, save/modify S does not store, E stores the value. +Or<replace withmodify CHANGE pressThe value can be changed after E; Press E again to save, S not to save |
6 |
50% contact force value 50%Fmax= N XXX. XX |
Set up touch force sensing50% value |
XXX.XX |
7 |
School Touch Power50% ADJ 50%Fmax AD=XXX save SAVE |
School contact force channel 50% points |
Press firstConfirm with E to display the sampled value, save/modify S does not store, E stores the value. +Or<replace withmodify CHANGE pressThe value can be changed after E; Press E again to save, S not to save |
8 |
25% touch force value 25%Fmax= N XXX. XX |
Set up touch force sensing25% value |
XXX.XX |
9 |
School Touch Power25% ADJ 25%Fmax AD=XXX save SAVE |
School contact force channel 25% points |
Press firstConfirm with E to display the sampled value, save/modify S does not store, E stores the value. +Or<replace withmodify CHANGE pressThe value can be changed after E; Press E again to save, S not to save |
10 |
Zero point of school contact force ADJ ZERO F=0 AD=XXX save SAVE |
School contact force channel 0% point AD0 |
Press firstConfirm with E to display the sampled value, save/modify S does not store, E stores the value. +Or<replace withmodify CHANGE pressThe value can be changed after E; Press E again to save, S not to save |
In the menu, pressThe "E" key enters the selected parameter modification state. If it is a numeric input type parameter, enter the number through the "+" key, “<”Press the key to move the input cursor position, press the "E" key to confirm the input, and the detector will automatically update the setting parameters and store them; If the parameter is a selection type, use a "+" or“<”Flip up and down the selection options, select the content and press the "E" key to confirm. The transmitter will automatically update the setting parameters and store them.