Overview

The SIS system and DCS system DO universal relay terminal board, XS-16DO-RL (universal) relay output terminal board, achieve complete isolation of SIS system and DCS system signals. The internal and external power supplies must be isolated, so this board requires an external power supply. The terminal marked L+/N - in the bottom left corner of the terminal board is the external power supply terminal.

Product Details

The SIS system and DCS system DO universal relay terminal board, XS-16DO-RL (universal) relay output terminal board, achieve complete isolation of SIS system and DCS system signals. The internal and external power supplies must be isolated, so this board requires an external power supply. The terminal marked L+/N - in the bottom left corner of the terminal board is the external power supply terminal. Each power supply provides two sets of power terminals to improve power supply capacity. DC24V or AC220V must be provided according to the load requirements, and no power supply is required for dry contact output.


sis系统和DCS系统通用继电器端子板DO16路


Product characteristic parameters:

Number of channels: 16;

Mode: Single line digital output, relay isolation;

Signal output: universal type, dry and wet optional, supports active/dual active/dry contacts 1NO+1NC;

Signal input: Common Yin and Common Yang can be set. Indication: Two color diode, with green for common Yin setting action and red for common Yang setting action;

Installation form: M5M6 screw.


sis系统和DCS系统通用继电器端子板DO16路


sis系统和DCS系统通用继电器端子板DO16路

Circuit setting: Changing the position of the fuse can switch the output mode (the fuse socket is reserved on the wiring board, and the position of the fuse can be changed);

Input the setting of co yin and co yang: switch K

Power settings: Each DB port contains a 4-core power cord for supplying power to the PLC module. These power supplies are controlled by short-circuit caps set by the power output, with each short-circuit cap corresponding to a wire, as shown in the following figure. They should be set as needed before power transmission. The power indicator is located below the fuse, and the power light does not light up when the power is reversed or the fuse burns out.