| Scope of application | Technical Specifications |
|---|---|
| Newly built residential communities or office buildings for domestic water use | Traffic: 6-300m³/h |
| The pressure of the bottom tap water cannot meet the high requirements for consumption | Lift: 30-200m |
| Production and domestic water use of water resistant industrial and mining enterprises | Speed: 1450-2900r/min |
| Type of circulatory system | Temperature range:≤80℃ |
| Work pressure: ≤ 2.0Mpa |

|
SGXW box pump integrated non negative pressure water supply equipment |
Product OverviewThe SGXW box pump integrated non negative pressure water supply equipment, which is commonly referred to as the "intelligent box pump station" and "box type non negative pressure water supply equipment", is the same thing. It is the seventh generation product upgraded and developed on the basis of the original variable frequency constant pressure water supply equipment and non negative pressure water supply equipment. It consists of a stainless steel water tank, a dedicated water pump, an intelligent variable frequency control cabinet, a non negative pressure device, a boosting device, a water diversion device, and a stabilizing tank. It is a new type of electromechanical integrated water supply equipment that combines computer technology, variable frequency technology, and motor pumps to meet the requirements of urban water supply networks. When pumping water, it does not generate negative pressure and has a certain regulation and storage capacity, and during peak periods, it continuously stops water supply. |
Equipment advantagesMany friends are not very familiar with what "integrated box pump non negative pressure water supply equipment" is. In fact, it is commonly referred to as "intelligent box pump station" and "box non negative pressure water supply equipment". It is the seventh generation product upgraded and developed on the basis of the original variable frequency constant pressure water supply equipment and non negative pressure water supply equipment. It consists of a stainless steel water tank, a dedicated water pump, an intelligent variable frequency control cabinet, a non negative pressure device, a boosting device, a water diversion device, and a stabilizing tank. It is a new type of electromechanical integrated water supply equipment that combines computer technology, variable frequency technology, and motor pumps to meet the needs of urban water supply networks. When pumping, it does not generate negative pressure and has certain regulation and storage capabilities. During peak periods, it is constantly improving. The requirement of water outage.The equipment adopts a microcomputer controlled variable frequency pump to operate at a constant speed, utilizing the existing pressure of tap water to ensure that the pressure required by the user is constant. It has the advantages of energy saving, environmental protection, low noise, and constant water supply pressure. |
Scope of application
1. Applicable geographical scope: Suitable for pressurized water supply in areas with sufficient pressure in urban pipeline networks |
working principleThe equipment is linked with the fire control center. Under normal conditions, the required pressure of the fire water supply network is maintained by controlling the stabilizing pump. When a fire alarm occurs, external signals such as the fire hydrant button and the fire control center are received to automatically turn on the main fire pump.
|
Product Introduction1、 Introduction to integrated water supply equipment without negative pressure box pumpThe integrated water supply equipment without negative pressure tank pump can be directly connected to the water supply network to ensure that there is no negative pressure in the water supply network. During peak hours, boosting the water in the closed water tank can compensate for the insufficient water supply in the water supply network and meet the water needs of users. It mainly consists of a closed water tank, a main pump unit, a variable frequency control cabinet, a boosting device, a water intake device, a steady flow tank, a non negative pressure flow controller, a pressure maintaining device, and a pressure sensor. The non negative pressure equipment unit is directly built into a stainless steel water tank to become an integrated pump station.
2、 Introduction to the Integrated Water Supply Equipment of Constant Pressure Variable Frequency Box Pump
In fact, the integrated water supply equipment of constant pressure variable frequency box pump is actually a variable frequency constant pressure water supply equipment. However, the principle of the variable frequency constant pressure water supply equipment is the same as that of the variable frequency constant pressure water supply equipment in the water tank. The municipal pipeline network is connected to the water tank, and then the equipment is connected to the water tank and pressurized through the equipment.
3、 Introduction to Integrated Fire Box Pump Water Supply Equipment
The integrated fire box pump water supply equipment is designed to solve the problem that the height of the high-level fire water tank in the temporary high-pressure fire water supply system cannot meet the static water pressure requirements of the unfavorable points of the system. It is a specialized fire box pump integrated fire pressure stabilizing equipment. It consists of a stainless steel water tank (assembled or welded), a pump room, a swirl preventer, a diaphragm pressure tank, a water pump, an electrical control box, instruments, pipelines, and accessories. The design capacity of the water tank for this equipment is the initial fire water consumption.
|
Application fieldNewly built residential communities, office buildings, hotels, and other domestic water sources. The pressure of low-level tap water cannot meet the requirements for firefighting water. Transforming the existing pneumatic water supply equipment can fully utilize the existing pneumatic tank. For already built water tanks, a non negative pressure equipment can be used to share the water supply with the tank, further saving energy. Intermediate booster pump station for water supply in the water plant. Production and domestic water use of industrial and mining enterprises.
|