- Phone
-
Address
No. 136, Lane 12, Rongle Middle Road, Songjiang District, Shanghai
Shanghai Fuzhan Environmental Protection Technology Co., Ltd
No. 136, Lane 12, Rongle Middle Road, Songjiang District, Shanghai
SENKO/Korean Sangko SP-MGTP Multi Gas Detector
1. SENKO SP-MGTP is an infrared combustible probe (as required by classification society regulations, combustible probes must be infrared and catalytic combustible probes cannot function properly in oxygen deficient environments)
2. SENKO SP-MGTP has CCS type approval certificate and CCS marine product certificate (with CCS label on the back of the machine)
3. SENKO SP-MGTP battery life can last for 5 days
4. SENKO SP-MGTP built-in pump sampling distance can reach 30 meters
SP-MGTP is a sampling gas detector that can simultaneously detect six gases that cause most industrial accidents, in order to protect workers from disasters caused by hypoxia, toxic gas poisoning, and gas explosions. SP-MGTP can detect up to 6 gases, including 37 different combinations of toxic and flammable gases, and display their concentrations, issuing alarms (visual, vibration, and auditory) when risks occur
Multi gas detection: providing comprehensive monitoring of multiple gases
Sampling type with built-in pump and probe: suitable for precise gas sampling in various environments
Real time monitoring: immediate feedback on changes in gas concentration
IP67 rating: Waterproof and dustproof, suitable for harsh environments
High performance alarm: providing visual, audible, and vibration alarms
Event recording: up to 30 events can be recorded for easy tracking
IrDA Communication: Convenient Data Transmission and Management
Single docking station: convenient for impact testing and calibration
Explosion proof certification: meets safety standards
Pump blockage alarm: An alarm is triggered when a pump blockage is detected
Filter contamination inspection: Visual inspection of filter element status
Three button operation: a simple and easy-to-use user control method
Product Inquiry
SP-MGTP is a sampling gas detector that can simultaneously detect six gases that cause most industrial accidents, in order to protect workers from disasters caused by hypoxia, toxic gas poisoning, and gas explosions. SP-MGTP can detect up to 6 gases, including 37 different combinations of toxic and flammable gases, and display their concentrations, issuing alarms (visual, vibration, and auditory) when risks occur
-Sampling method with built-in pump and probe
-Can detect up to 6 gases and support 37 gas combinations
-Event recording function (last 30 events/impact testing/calibration)
-Easy maintenance (probe and host built-in dual filter)
-The inner wall of the gas pipeline is coated with Teflon
-Support IrDA infrared communication
-Supporting single docking station

| model | SP-MGTP |
|---|---|
| display screen | Segmented LCD display screen, backlight, indicator lights |
| button | 3 operation and setting buttons |
| sensor | Electrochemical sensors: Toxic gases and oxygen (O ₂) PID sensor: VOC gas Catalytic/NDIR Sensor: Combustible Gas |
| alarm | Visual: LCD alarm display, backlight Indicator light, sound alarm (buzzer, 90dB@10cm ) |
| size | 77(W) x 146(H) x 43(D) mm |
| weight | 490 grams |
| Installation method | Waist clip fixation |
| Operating Temperature | -20°C ~ +50°C |
| Operating Humidity | 10%~90% RH (non condensing) |
| protection level | IP67 |
| pressure range | 80 ~ 120kPa |
| sampling method | built-in pump |
| Battery Type | Rechargeable lithium-ion battery (4000mAh) |
| Usage time | SP-MGTP-P0 series: approximately 30 hours SP-MGTP-N0/N1/N2 series: about 5 days or more |
| Shell material | TPU coated polycarbonate (PC) |
| Optional features | IR Link (Infrared Communication) |
| flow range | 250 ~ 300cc |
| Sampling hose length | The longest sampling distance is 30 meters |
SP-MGTPEquipped with four sensor slots, providing flexible and diverse gas detection capabilities. Its modular design supports the combination of different gas sensors to meet specific monitoring needs. The following is a list of optional sensors for each slot, which can be configured according to different industrial and safety applications.
SP-MGTPWe offer a variety of gas sensor options, each designed for specific environments with different detection ranges, resolutions, and alarm settings to ensure accuracy and reliability of detection. The following are the technical specifications of optional sensors:
| gas | sensor type | Testing Scope | resolution | Low alarm | High alarm |
|---|---|---|---|---|---|
| Oxygen (O ₂) | Electrochemical formula | 0 ~ 30 %vol | 0.1 %vol | 19 %vol | 23 %vol |
| Carbon monoxide (CO) | Electrochemical formula | 0 ~ 1000 ppm | 1 ppm | 30 ppm | 60 ppm |
| Hydrogen sulfide (H ₂ S) | Electrochemical formula | 0 ~ 200 ppm | 0.1 ppm | 10 ppm | 15 ppm |
| Methane (CH ₄) | Catalytic/Non Dispersive Infrared (NDIR) | 0 ~ 100 %LEL | 1 %LEL | 10 %LEL | 30 %LEL |
| Carbon dioxide (CO ₂) | Non dispersive infrared (NDIR) | 0 ~ 5 %vol | 0.01 %vol | 0.5 %vol | 1.0 %vol |
| Ammonia gas (NH3) | Electrochemical formula | 0 ~ 100 ppm | 1 ppm | 25 ppm | 35 ppm |
| Sulfur dioxide (SO ₂) | Electrochemical formula | 0 ~ 20 ppm | 0.1 ppm | 2 ppm | 5 ppm |
| Hydrogen (H ₂) | Electrochemical formula | 0 ~ 1000 ppm | 1 ppm | 100 ppm | 500 ppm |
| Nitrogen dioxide (NO ₂) | Electrochemical formula | 0 ~ 20 ppm | 0.1 ppm | 3 ppm | 5 ppm |
| Chlorine gas (Cl ₂) | Electrochemical formula | 0 ~ 20 ppm | 0.1 ppm | 0.5 ppm | 1 ppm |
| Hydrogen (HF) | Electrochemical formula | 0 ~ 10 ppm | 0.1 ppm | 0.5 ppm | 1.0 ppm |
| Hydrogen hydride (HCN) | Electrochemical formula | 0 ~ 50 ppm | 0.1 ppm | 10 ppm | 20 ppm |
| Hydrogen (HCl) | Electrochemical formula | 0 ~ 20 ppm | 0.5 ppm | 2 ppm | 5 ppm |
| VOC(PID) | Photoionization detector (PID) | 0 ~ 4000 ppm | 1 ppm | 50 ppm | 200 ppm |
| Nitric oxide (NO) | Electrochemical formula | 0 ~ 500 ppm | 0.5 ppm | ||
| Hydrogen oxide (H ₂ O ₂) | Electrochemical formula | 0 ~ 100 ppm | 0.1 ppm |