Welcome Customer !

Membership

Help

Shandong Baisentaike Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shandong Baisentaike Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 19 Keyuan Road, Lixia District, Jinan City

Contact Now

SBA-40D Biosensing Analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The SBA-70 Biosensing Automatic Analyzer uses enzymatic reactions for quantitative analysis, with the key sensor being a composite sensor of immobilized enzymes and H2O2 electrodes. The analysis process is based on the following biochemical reactions: substrate immobilized enzyme membrane product, arginine O2+H2O arginine oxidase alpha ketoglutarate+NH4+H2O2 glucose O2+H2O glucose oxidase gluconate H2O2 lactate O2+H2O lactate oxidase pyruvate H2O2, ethanol O2+H2O ethanol oxidase acetic acid H2O2

Product Details

SBA-70The type of biosensing automatic analyzer uses enzymatic reactions for quantitative analysis, and the key sensors for measurement are immobilized enzymes andH2O2The electrode composite sensor is analyzed based on the following biochemical reactions:

bottom thing

Immobilized enzyme membrane

production thing

amino acid

O2H2O

Amino acid oxidase

alpha-Ketoglutaric acid+NH4

H2O2

glucose

O2H2O

glucose oxidase

Gluconic acid

H2O2

lactic acid

O2H2O

Lactate oxidase

Pyruvic acid

H2O2

ethanol

O2H2O

Ethanol oxidase

acetic acid

H2O2

Accurately diluted with buffer solution (ensuringpHin7A sample with a certain ion strength (left and right) is quantitatively aspirated by an automatic sampling needle and then pushed to the surface of the immobilized enzyme sensor by a flow pump. The substrate in the sample reacts with the immobilized enzyme membrane, and the reaction releasesH2O2Through the inner layer of the enzyme membrane, electrons are lost on the surface of the platinum electrode and reduced toH2OThe platinum electrode obtains electrons to generate a current signal, which is related toH2O2The concentration is proportional, andH2O2The concentration is linearly proportional to the substrate concentration. By comparing the measured substance with the standard sampleH2O2Quantity can be used to calculate the content of substrate in the tested sample. After the reaction is completed, the sample is pushed into the waste liquid bottle by the flow pump. When the residual sample on the surface of the immobilized enzyme sensor is lower than the concentration that does not affect the next measurement, the measurement of the next sample will automatically start