Rotating droplet interfacial tensiometer

NegotiableUpdate on 12/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The TX500C rotary droplet interfacial tension meter features an upgraded self sealing sample tube, horizontal control mechanism for the sample tube, camera and imaging system, self heating system, detachable sample tube, and no eye fatigue caused by flickering images.

Product Details

The TX500 Rotating Drop Ultra Low Interface Tension Meter is a professional interface tension meter from the United States. The TX500C series is a classic rotating drop ultra-low interface tension meter based on the innovative technologies of the American company, such as the detachable sample tube and the integral aluminum alloy block heating system. It has independent operation of the host and dual software control functions, making it easy to operate. It can analyze interface tension values as low as 10-6mN/m, analyze dynamic interface tension values, as well as oscillation drops, viscoelastic coefficients, interface rheology, expansion properties, etc. It can be widely used in industries such as daily chemical products, oil field tertiary recovery, microemulsions, surfactants, etc.

Ultra low interfacial tension of rotating droplets:

The increase in free energy per unit interface area under constant temperature and pressure is called interfacial tension. This system originates from the different attractive forces of molecules on both sides of the interface towards the molecules on the interface. Different from typical interfacial tension testing, the rotating drop testing technique can analyze low interfacial tension, while conventional methods such as platinum plate method and platinum ring method cannot achieve such measurements.

Usually, we refer to the interfacial tension of 10-2-10-1mN/m as low interfacial tension, while the interfacial tension below 10-3mN/m is called ultra-low interfacial tension.

To determine ultra-low interfacial tension, it is necessary to artificially alter the balance between gravity and interfacial tension of the system, so that the droplet at equilibrium is closer to the ideal shape for measuring interfacial tension values. This can be achieved by rotating the system and increasing the effect of the centrifugal force field. This is the principle of ultra-low interfacial tension testing for rotating droplets.


Rotating droplet interfacial tensiometerApplication scope of TX500C


Analysis and measurement of interfacial tension in the tertiary oil recovery process of oil fields

→ Interfacial tension test of lotion and polymer

→ Interface tension test of medicine, pesticide, spray, paint and coating

Analysis of interfacial tension in cosmetics and food industries

→ Surfactants, soaps, and detergents


When testing for typical interfacial tension values (>1mN/m), it is recommended to purchase the A601/A101 fully automatic surface tension meter for higher measurement accuracy



Rotating droplet interfacial tensiometerTX500C technical features:
This instrument adopts a modular design, integrating a pluggable quartz sample tube (φ 2/4/6mm) and an aluminum alloy heating block temperature control system (room temperature -100 ℃± 1 ℃), supporting RS232/USB dual communication protocol, and suitable for oilfield and laboratory environments.

Key points for hardware upgrade

  1. Sample processing system

    • Two end open quartz tube design reduces bubble interference, makes cleaning more convenient, and avoids cross contamination

    • Top in clamping structure ensures a horizontal deviation of less than 1 °

  2. Temperature Control System

    • Aluminum alloy block homogenization technology (25-100 ℃ thermal uniformity ± 0.8 ℃)

    • Optional gas thermal temperature control module (-10-200 ℃)

  3. imaging system

    • Adjustable LED cold light source (0-100% brightness)

    • Strobe mode (1-60Hz) suitable for observing turbid samples

CAST ® 4.0 Software Features

  • Automated testing process:
    ▶ Single key start image acquisition → contour recognition → tension calculation (based on Vonnegut equation)
    ▶ Support real-time curve generation of temperature/speed gradient experimental data

  • Data management module:
    ▶ Associated storage of original images and test parameters
    ▶ EXCEL report export (including operation log traceability function)
    ▶ Secondary correction of measurement results (retaining initial data)

Operational performance indicators

  • Speed control: 0-10000rpm ± 5rpm (driven by PID motor)

  • Tension range: 0.01-100mN/m (accuracy ± 2%)


TX500C Rotating Drop Ultra Low Interface Tension Tester TX500C Technical Parameters:

旋转滴界面张力仪

TX500 Rotating Drop Ultra Low Interface Tension Tester TX500C Series Configuration List

1. 1 host (excluding computer);

2. One set of industrial imaging system;

3. Two RS-232 serial port cables and one USB data cable;

4. 1 power cord;

5. 5 needles with a length of 10cm for syringes

6. 5 sample tubes with inner diameters of 4 and 6mm and open ends at each end;

7. Two sample tubes with inner diameter of 2mm and self sealing openings at both ends;

8. 5 sets of sealing plugs for centrifuge tubes

9. Two main engine rotating shaft pressure caps;

10. 1 instrument calibration standard tube





CAST®Asha®、ADSA®、TrueDrop®、RealDrop®、TheDrop®、MicroDrop®、LMCA®、Shsolon®Solon®Register a trademark for Shanghai Solon.

The above trademark is used for goods or services related to contact angle measuring instruments, surface tension meters, and interfacial tension meters. Infringement will be prosecuted!