Rosemount multivariable transmitters enable differential pressure, static pressure, and process temperature measurements in one device, reducing installation costs and helping you gain a deeper understanding of the process.
Can small changes in pressure and temperature cause major issues in your flow measurement?
The changing process conditions affect the accuracy and repeatability of flow measurement, and may also lead to equipment failure. Through the Rosemount 3051S MultiVariable ™ The transmitter allows you to perform three types of process measurements and flow calculations in a single device, and can be calibrated according to changing process conditions, so each reading is very accurate. This means that it can enhance your control over rapidly changing process conditions, thereby increasing productivity.
The Rosemount 3051SMV flowmeter can provide you with all the engineering design required to complete mass and energy flow calculations. Using Rosemount Engineering Assistant ™ The configuration software allows for easy configuration of the Rosemount 3051SMV in just two steps. You can also order the Rosemount 3051SMV pre configured at the factory according to your specific application needs.
The 3051S MultiVariable transmitter is the most widely used differential pressure flow product on the market. Learn more about the extensive features of 3051SMV to help you better manage application related information.
Excellent measurement. Real results.
Excellent measurement is the key to excellent control. The 3051SMV integrates multivariate measurements into the industry-leading 3051S scalable platform, providing unprecedented performance and functionality for better control of raw materials, combustion, reactions, mixing, and product quality.
| Measurement type |
Multivariate measurement |
| output |
HART® |
| Reference accuracy |
trafficAt a flow regulation ratio of 14:1, the flow accuracy is ± 0.65%
differential pressure± 0.04% differential pressure reading and 200:1 differential pressure regulation ratio
Absolute pressure and gauge pressure± 0.25% range and 200:1 drop amplitude
Process temperature RTD interface:±0.67 ºF (0.37 ºC) - Sensor matching achieved through Callendar Van Dusen constant |
| long-term stability |
10-year stability |
| warranty |
12 year limited warranty |
| variable |
Quality, volume, and energy flow rate cumulative flow differential pressure Static pressure (gauge pressure and absolute pressure) process temperature |
available computation type |
Fully compensated quality and energy flow rate Direct process variable output |
available measurement combination |
Differential pressure, static pressure, and process temperature Differential pressure and static pressure Differential pressure and process temperature differential pressure |