Rosemount 3051S Multivariable Transmitter and Flow Meter

NegotiableUpdate on 06/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Will small changes in pressure and temperature cause major problems in your flow measurement? The changing process conditions affect the accuracy and repeatability of flow measurement, and may also lead to equipment failure. Through the Rosemount 3051S Mul

Product Details

Realize innovation in operation
Can small changes in pressure and temperature cause major issues in your flow measurement?
The changing process conditions affect the accuracy and repeatability of flow measurement, and may also lead to equipment failure. Through the Rosemount 3051S MultiVariable ™ The transmitter allows you to perform three types of process measurements and flow calculations in a single device, and can be calibrated according to changing process conditions, so each reading is very accurate. This means that it can enhance your control over rapidly changing process conditions, thereby increasing productivity.
The Rosemount 3051SMV flowmeter can provide you with all the engineering design required to complete mass and energy flow calculations. Using Rosemount Engineering Assistant ™ The configuration software allows for easy configuration of the Rosemount 3051SMV in just two steps. You can also order the Rosemount 3051SMV pre configured at the factory according to your specific application needs.
measurement type Multivariate measurement
output HART ®
Reference accuracy internet trafficAt a flow regulation ratio of 14:1, the flow accuracy is ± 0.65%
differential pressure± 0.04% differential pressure reading and 200:1 differential pressure regulation ratio
Absolute pressure and gauge pressure± 0.25% range and 200:1 drop amplitude
Process temperature RTD interface:±0.67 ºF (0.37 ºC)
- Sensor matching achieved through Callendar Van Dusen constant
Long term stability 10-year stability
warranty 12 year limited warranty
variable Quality, volume, and energy flow rate
Traffic
differential pressure
Static pressure (gauge pressure and absolute pressure)
process temperature
available
Calculation type
Fully compensated quality and energy flow rate
Direct process variable output
available
measure
combination
Differential pressure, static pressure, and process temperature
Differential pressure and static pressure
Differential pressure and process temperature
differential pressure