Have you ever considered implementing stricter control over tall storage tanks and towers in order to maximize production capacity through innovation in operation? Excessive process fluctuations caused by incorrect or missing process information often increase the difficulty of achieving maximum output. due to
Realize innovation in operation
Have you considered implementing stricter control over tall storage tanks and towers to maximize production capacity?
Excessive process fluctuations caused by incorrect or missing process information often increase the difficulty of achieving maximum output. Due to the easy blockage, leakage, condensation, and evaporation of pressure pipes, this situation usually occurs in installation operations that rely on pressure pipes.
Using the Rosemount 3051S ERS system eliminates the need for pressure pipes and improves reliability. The electronic remote sensor system replaces mechanical pressure pipes with two 3051S pressure sensors connected digitally together, allowing you to obtain more accurate and complete information. Improve performance
Response time has increased by 90%
100% elimination of temperature influence and measurement deviation
Mature 3051S sensor technology enjoys 10 years of stability and 12 years of warranty
Simplify installation
Each sensor can be independently installed by an instrument technician
Easy connection of sensors using non dedicated wires
No need for heat tracing or insulation
Gain a deeper understanding of the process
Real time monitoring of steam pressure in storage tanks
Track the temperature of each sensor module
Proactive maintenance and troubleshooting through sensor diagnostics and configurable process alerts
Reduce spare parts and routine maintenance
Each sensor can be repaired separately, reducing downtime during the process
Simplify your inventory with sensors and standard cables
No need to carry capillary systems of different lengths
Easy to integrate
The entire system uses a 2-wire 4-20 mA HART loop
The graphical interface of the device dashboard allows for easy configuration, debugging, and troubleshooting
Pre programmed and synchronized differential pressure calculation
Electronic remote sensor technology has been successfully applied in various industries and conditions, including:
High type container
Due to the relatively long lengths of pressure pipes and capillaries typically required for tall containers, measurement deviations caused by changes in ambient temperature can be amplified. The 3051S ERS system eliminated these mechanical components, achieving stable and repeatable measurements.
distillation column
The 3051S ERS system provides accurate differential pressure measurement to provide reliable indications of the condition of filters, trays, and seals. Additional multi parameter measurement and diagnosis can enable proactive maintenance operations, which prevent overflow and other hazardous process conditions from occurring.
Installation in cold weather
Installation in cold weather conditions typically requires steam heating or electric tracing, insulation, and other complex operations. The digital architecture of the 3051S ERS system avoids these operations, simplifying installation while reducing maintenance work.
| product |
Rosemount 3051S Electronic Remote Sensor |
| Measuring principle |
Use two gauge/absolute pressure sensors for pressure measurement to calculate differential pressure |
| Transmitter model |
3051SAM、3051SAL |
| process connection |
3051SAM: flange NPT、 Instrument valve group, 1199 seal 3051SAL: Flanged, threaded, and sanitary direct mount seals |
| output |
4-20 mA, Equipped with HART (revised version 6) |
| Measurement range |
Up to 150 ft (45 m) in length |
| variable |
differential pressure PHIAnd PLOpressure PHIAnd PLOSensor module temperature Variable scale variables (up to 20 points) |
| Reference accuracy |
Differential pressure: ± 0.035% differential pressure range Gauge pressure/absolute pressure: ± 0.025% calibrated sensor range |
| long-term stability |
10-year stability |
| warranty |
12 year limited warranty |