Welcome Customer !

Membership

Help

Shanghai Aoxi Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Aoxi Scientific Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    3rd Floor, Building 1, No. 552 Liancao Road, Minhang District

Contact Now

Residual detection of ethylene oxide GC5890N gas chromatograph

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

GC5890N gas chromatograph with ethylene oxide capillary column for residual detection of ethylene oxide. 1. Instrument introduction: Multiple detectors, packed columns, and split/non split capillary column injection systems can be selected; Fully compatible with Agilent 6890N gas chromatograph detector and related detector control board, chromatography workstation, and automatic sampler. Cost effectiveness, excellent performance, stable and reliable operation. $r $n II. Application Fields $r $n Petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water affairs, power, metallurgy, research institutes, and quality inspection departments.

Product Details

Residual detection of ethylene oxideGC5890Ngas chromatograph

matchEthylene Oxidecapillary columndetectionEthylene Oxideresidual amount

1Instrument Introduction

Multiple detectors, packing columns, and flow dividers can be optionally selected/Non split capillary column injection system; Fully compatible with Agilent6890NGas chromatograph detector and related detector control board, chromatography workstation, and automatic sampler. Cost effectiveness, excellent performance, stable and reliable operation.

IIapplication field

Petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water affairs, power, metallurgy, research institutes, quality inspection departments.

IIImatching products

Headspace sampler, gas generator, gas purifier, thermal analyzer, cracker, etc.

4Performance characteristics

Newly integrated digital electronic circuit with high control accuracy, stable and reliable performance, capable of reaching0.01Temperature control accuracy of ℃.

It has self diagnostic function upon startup, stopwatch function (convenient for stable flow), running timer function, power-off storage protection function, keyboard locking function, anti power mutation interference function, networked data communication and remote control function.

The design of the injection system * can achieve lower detection limits.

Optional automatic/Manual gas six way injection valve injector, headspace injector, thermal analysis injector, cracking furnace injector, methane converter, automatic injector.

Program heating and precise control of furnace temperature for stable balance are faster and more efficient.

InstallableFIDTheTCDTheFPDTheNFDThePDHIDSix types of detectors, each with independent temperature control. The hydrogen flame detector is easy to disassemble and install, making it convenient for cleaning or nozzle replacement. Thermal conductivity pool detector(TCD)Stability time ≤20min.

It has automatic online detection function.

5technical indicators

column oven

Furnace size:28×30×18cm

Temperature range: room temperature5~450

Temperature setting:1℃; Program set heating rate0.1

High heating rate:120/ min

Temperature stability: When the ambient temperature changes1At ℃, for0.01

Program heating up:7Step program temperature rise

VIdetector

Hydrogen flame ionization detector(FID

Temperature limit for use:400

Detection limit: ≤5×10-12g/s [n-C16]

Drift: ≤5×10-13A/30min

Noise: ≤2×10-13A

Dynamic linear range: ≥107

Thermal conductivity pool detector(TCD

Temperature limit for use:400

Sensitivity: ≥10000mv.ml/mg [n-C16]

Drift:100MV/30min

Noise: ≤2×10-13A

Dynamic linear range: ≥104

Photoelectric ionization detector(PDHID

Flame photometric detector(FPD

Temperature limit for use:250

Detection limit:2x10-13 gs(P),5x10-11g/sS

Dynamic linear range:103P),≥102S

Noise: ≤2×10-12A

Drift: ≤4x10-11A/30min

Electron capture detector(ECD

Temperature limit for use:350

Detection limit:1x10-14g/ml(y-666)

Dynamic linear range:104

Noise: ≤20MA

Drift: ≤50MV/30min

Nitrogen and phosphorus detector(NPD

Temperature limit for use:400

Detection limit:5x10-13 gs(P),1x10-12g/sN

Dynamic linear range:103P),≥103N

Noise: ≤4×10-13A

Drift: ≤2.5x10-12A/30min

detection limit5ppb