Residual detection of ethylene oxideGC5890Ngas chromatograph
matchEthylene Oxidecapillary columndetectionEthylene Oxideresidual amount
1Instrument Introduction
Multiple detectors, packing columns, and flow dividers can be optionally selected/Non split capillary column injection system; Fully compatible with Agilent6890NGas chromatograph detector and related detector control board, chromatography workstation, and automatic sampler. Cost effectiveness, excellent performance, stable and reliable operation.
IIapplication field
Petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water affairs, power, metallurgy, research institutes, quality inspection departments.
IIImatching products
Headspace sampler, gas generator, gas purifier, thermal analyzer, cracker, etc.
4Performance characteristics
Newly integrated digital electronic circuit with high control accuracy, stable and reliable performance, capable of reaching0.01Temperature control accuracy of ℃.
It has self diagnostic function upon startup, stopwatch function (convenient for stable flow), running timer function, power-off storage protection function, keyboard locking function, anti power mutation interference function, networked data communication and remote control function.
The design of the injection system * can achieve lower detection limits.
Optional automatic/Manual gas six way injection valve injector, headspace injector, thermal analysis injector, cracking furnace injector, methane converter, automatic injector.
Program heating and precise control of furnace temperature for stable balance are faster and more efficient.
InstallableFIDTheTCDTheFPDTheNFDThePDHIDSix types of detectors, each with independent temperature control. The hydrogen flame detector is easy to disassemble and install, making it convenient for cleaning or nozzle replacement. Thermal conductivity pool detector(TCD)Stability time ≤20min.
It has automatic online detection function.
5technical indicators
column oven
Furnace size:28×30×18cm
Temperature range: room temperature5~450℃
Temperature setting:1℃; Program set heating rate0.1℃
High heating rate:120℃/ min
Temperature stability: When the ambient temperature changes1At ℃, for0.01℃
Program heating up:7Step program temperature rise
VIdetector
Hydrogen flame ionization detector(FID)
Temperature limit for use:400℃
Detection limit: ≤5×10-12g/s [n-C16]
Drift: ≤5×10-13A/30min
Noise: ≤2×10-13A
Dynamic linear range: ≥107
Thermal conductivity pool detector(TCD)
Temperature limit for use:400℃
Sensitivity: ≥10000mv.ml/mg [n-C16]
Drift:≤100MV/30min
Noise: ≤2×10-13A
Dynamic linear range: ≥104
Photoelectric ionization detector(PDHID)
Flame photometric detector(FPD)
Temperature limit for use:250℃
Detection limit:≤2x10-13 gs(P),≤5x10-11g/s(S)
Dynamic linear range:≥103(P),≥102(S)
Noise: ≤2×10-12A
Drift: ≤4x10-11A/30min
Electron capture detector(ECD)
Temperature limit for use:350℃
Detection limit:≤1x10-14g/ml(y-666)
Dynamic linear range:≥104
Noise: ≤20MA
Drift: ≤50MV/30min
Nitrogen and phosphorus detector(NPD)
Temperature limit for use:400℃
Detection limit:≤5x10-13 gs(P),≤1x10-12g/s(N)
Dynamic linear range:≥103(P),≥103(N)
Noise: ≤4×10-13A
Drift: ≤2.5x10-12A/30min
detection limit≤5ppb