The SD660N-6A area fixed radiation alarm monitor, also known as the area radiation monitoring system, is a device used for continuous monitoring of X/γ rays in radioactive sites such as radiation source warehouses, nuclear fuel processing, medical radiation, irradiation, industrial accelerators, radiation testing, public environmental areas, etc.
Product Details


Regional fixed radiation alarm monitoring instrumentRegional Radiation Monitoring SystemRegional radiation monitoring device

Model:SD660N-6A


Introduction

The SD660N-6A regional radiation monitoring system is a device used for continuous X/gamma ray monitoring in radioactive sites, such as radiation source warehouses, nuclear fuel processing, medical radiation, irradiation, industrial accelerators, radiation testing, public environmental areas, etc.

The equipment mainly consists of a host (SD660N-6A) and a detector integrated machine (SD660N-T) or detector (without display). The host can connect multiple detectors based on the actual situation on site and provide X/γ dose rate data measured by each detector. When the X/γ dose rate in the tested area exceeds the set alarm threshold, the host and detector will simultaneously issue alarm signals to alert on-site personnel and ensure their safety. The detector all-in-one machine can be used independently (equipped with 24V power supply) or networked with the host for flexible configuration according to the on-site situation.



Regional radiation monitoring deviceTechnical performance:

Detector:

Detection of radiation types: X, γ;

Detector type: GM tube;

Energy range: 48 keV to 3 MeV;

Reference energy: 137Cs, 662keV;

Measurement range: 0.01 μ Sv/h to 1Sv/h;

Response time: 1 second;

Basic error: ≤± 15% (137Cs, 662keV);

Transmission distance: greater than 500m;

Power supply voltage: 24V DC;

7-inch touch screen


Regional fixed radiation alarm monitoring instrumenthost

10 inch touch screen, resolution: 1024 * 600, user-friendly human-machine interface;

Summarize and display all detector measurement data, alarm thresholds, equipment status, and equipment location;

Customize Chinese input to edit the location name of the detector;

Display units: μ Sv/h, mSv/h, Sv/h (instrument automatically switches units);

The alarm threshold is continuously adjustable, with sound and light alarms;

Provide DC 24V voltage for the detector

Usage environment: Temperature -20 ℃~50 ℃, relative humidity ≤ 90% RH;

Instrument features:

The main display unit adopts a 10 inch LCD touch screen, and the detector can be an all-in-one machine with a 7-inch touch screen structure or a conventional device without a display probe or a mixed installation, which is convenient for determining whether to display data according to the on-site situation;

Both the host and detector integrated machine can store measurement results, including alarm information, and export them through a USB flash drive (USB interface), as well as query corresponding time period data information through start and end dates;

The detector integrated machine can display measurement results in real time and can also indicate measurement results through a simulated dial;

Both the host and detector all-in-one machines are equipped with user management options (including adding users, modifying users, deleting users, etc.) for password protection of system parameters. The detector all-in-one machine has a buzzer physical switch and can set screen sleep time;

Detector alarm indicator light: green light - normal red light - alarm;

The main display unit can display the real-time curve of the detector and set the upper and lower limits of the curve display;

Notes:

All interfaces cannot be plugged in or unplugged with power on;

This instrument belongs to precision measuring instruments and should avoid collisions and drops;

If the instrument is not used for a long time, please turn off the power and store the instrument in a dry and normal temperature environment;

Non professionals are not allowed to disassemble instruments or open components;

If the instrument malfunctions, it needs to be handled by professional technicians.