Welcome Customer !

Membership

Help

Nanjing Yixun Biotechnology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Nanjing Yixun Biotechnology Co., Ltd

  • E-mail

  • Phone

  • Address

    158 Xiaoxing Road

Contact Now

Rat Kidney Injury Molecule-1 (Kim-1) ELISA Detection Kit

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Name: Rat Kidney Injury Molecule 1 (Kim-1) ELISA Detection Kit $r $n $r $n Product Code: YXR31104 $r $n $r $n Product Batch Number: Please refer to the product label $r $n $r $n Shelf Life: 6 months $r $n $r $n Storage Conditions: 2-8 ℃ $r $n $r $n Product Usage: $r $n $r $n This kit is used for in vitro quantitative detection of rat kidney injury molecule 1 (Kim-1) content in serum, plasma, tissue homogenates, and related liquid samples.

Product Details

1、 Product information:

Product Name:Rat Kidney Injury Molecule-1 (Kim-1) ELISA Detection Kit

Product Code: YXR31104

Product batch number: see product label for details

Validity period: 6 months

Storage conditions: 2-8 ℃

Product Usage

This kit is used for in vitro quantitative detection of the content of rat kidney injury molecule 1 (Kim-1) in serum, plasma, tissue homogenate, and related liquid samples.

2、 Detection principle:

The reagent kit adopts a double antibody one-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the sample, standard, and HRP labeled detection antibody in sequence to the pre coated micropores of the rat kidney injury molecule 1 (Kim-1) capture antibody, incubate and thoroughly wash. Using substrate TMB for color development, TMB is converted to blue under the catalysis of peroxidase and to the final yellow under the action of acid. The depth of color is positively correlated with the presence of rat kidney injury molecule 1 (Kim-1) in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader and calculate the sample concentration.

3、 Sample collection, processing, and preservation methods:

The following is just a general guide for sample collection. Sodium azide should not be used as a preservative during all sample collection processes.

1. Serum: Use test tubes that do not contain pyrogens or endotoxins, and avoid any cell irritation during the operation. Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or overnight at 4 ℃, then centrifuge at 1000 × g for 20 minutes, and take the supernatant. Alternatively, store the supernatant at -20 ℃ or -80 ℃, but avoid repeated freezing and thawing.

2. Plasma: Collect specimens using EDTA or heparin as anticoagulants, and centrifuge the specimens at 2-8 ℃ 1000 × g for 15 minutes within 30 minutes after collection. The supernatant can be collected for detection, or stored at -20 ℃ or -80 ℃, but repeated freezing and thawing should be avoided.

3. Cell culture supernatant or other biological specimens: Centrifuge at 1000 × g for 20 minutes to obtain the supernatant for detection, or store the supernatant at -20 ℃ or -80 ℃, but avoid repeated freezing and thawing.

4. Tissue homogenate: Rinse the tissue with pre cooled PBS (0.01M, pH=7.4) to remove residual blood (lysed red blood cells in the homogenate can affect measurement results), weigh and cut the tissue into pieces. Mix the shredded tissue with the corresponding volume of PBS (usually in a weight to volume ratio of 1:9, for example, 1g of tissue sample corresponds to 9mL of PBS, the specific volume can be adjusted appropriately according to experimental needs, and records should be kept. Recommend adding protease inhibitors to PBS and grinding thoroughly on ice in a glass homogenizer. To further lyse tissue cells, the homogenate can be sonicated or subjected to repeated freeze-thaw cycles. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes and collect the supernatant for detection.

Note: Hemolysis of specimens can affect the final test results, therefore hemolytic specimens are not suitable for this test.

5. Storage: If the sample is not tested in a timely manner after collection, please divide it into batches according to a single dose, freeze it at -20 ℃, avoid repeated freezing and thawing, thaw it at room temperature, and ensure that the sample is evenly filled and thawed.



Yixun Biotechnology provides free testing services to help scientific research worry free!

The selection and use of ELISA kits are crucial for the experimental results in scientific research experiments. In order to help you complete experiments more efficiently and accurately, we have specially launched the "ELISA Kit Free Testing Service", allowing you to focus on scientific research and innovation without worrying about experimental operations and data analysis!



The advantages of free testing services:

1. Time and effort saving: You only need to provide samples, and we will complete the experimental operation and data analysis for you, greatly reducing the experimental cycle and freeing up your research energy.

2. Accurate and reliable: The entire experiment was conducted in a GLP compliant laboratory, operated by an experienced technical team to ensure the accuracy and reproducibility of the experimental results.

3. Personalized customization: supports single sample multi index detection, high-throughput screening of large samples, optimizes experimental plans for special samples (such as low abundance targets and complex matrices), ensuring data accuracy and traceability.

4. Intelligent report: We provide raw data, standard curve graphs, and statistical analysis, support multi-dimensional data visualization, and can combine your needs for in-depth bioinformatics interpretation, providing solid support for research conclusions.


Rat Kidney Injury Molecule-1 (Kim-1) ELISA Detection Kit