Rapid detection kit for inorganic total nitrogen water quality

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Inorganic total nitrogen water quality rapid detection kit. After opening the total nitrogen kit, place the unused packaging test tube in the provided fresh-keeping bag and use it as soon as possible. According to storage conditions, reagents may deteriorate within a few days, especially in hot and humid weather.

Product Details

Rapid detection kit for inorganic total nitrogen water quality

638341969460677033886.jpg


Range selection

0-20mg/L

0-100mg/L

Customization of other ranges

detection method

1698571941463.png

Precautions

  1. This product can measure the total value of inorganic nitrogen and is not used to determine organic nitrogen. The optimal pH value for the reaction is around 13. If the pH value of the sample is below 4, please neutralize it with diluted * solution before measurement. 2. Use a 1000mg/L standard solution, and the color of the standard color should be darker than 100mg/L. If the value is expected to be higher, please dilute the sample before use. 3. Keep the sample temperature between 15-30 ℃. 4. Before use, rinse the small pipette with clean water or the same sample for measurement. 5. Using measuring straws instead of plastic straws will provide better accuracy. 6. After adding K-2 reagent, reduction reaction will occur, and foam will occur in the sample. Remove the lid from the cup to prevent leakage of strong alkaline solution, while keeping it for 15 minutes. 7. Ensure that the filled PACKTEST tube is half filled. If the tube cannot be filled immediately, shake it 10 times, hold the top of the hole, press the tube again, and try to pull the sample into the tube. After taking the complete sample, invert the tube 2-3 times. 8. Unsolved K-2 reagent may remain in the battery, but it will not affect the measurement. 9. Some undissolved reagents will not affect the measurement of color comparison. When comparing with standard colors, please make sure to read under sunlight. It is difficult to determine the color under direct sunlight, certain fluorescent lamps, mercury lamps, or LEDs. You can put the line back into the aperture seal. This will avoid the possibility of material spillage inside the pipe.

interfering factor

Interference: Prepare standard colors based on standard solutions. If there are coexisting substances that may cause interference, please compare and verify with standard methods or standard addition methods. The following is a list of acceptable levels of interference data obtained by adding each individual substance to the standard solution.

1698572040323.png