As a top tier dry type temperature calibrator (dry furnace),JOFRA RTC159 has excellent performance, with a minimum temperature of -100 ℃, making it an ideal temperature calibration instrument for industries such as pharmaceuticals, biomedicine, food, and metrology.
JOFRA RTC159 has the following advantages:
1.Many related applications. Due to its wide temperature range and the ability to reach extremely low temperatures,RTC159 can be applied in some fields that require ultra-low temperatures.
2.There is a good user interface. The calibration process is simple to operate and easy to run, with a color large screen LCD display that provides comprehensive and intuitive calibration information.
3.Portable ultra-low temperature calibrator. Lightweight, easy to carry, and convenient to change calibration locations.
4.Trustworthy quality.RTC159 adopts multiple cutting-edge technologies to ensure long-term stability of its performance indicators.
1.Temperature range:-100~155℃;
2.Accuracy:±0.3℃(Built in standards,type a),±0.06℃(join in marriageExternal standard,OnlyBC type);
3.Stability:±0.03℃;
4.Display resolution:1/0.1/0.01/0.001 ℃ adjustable;
5.Calibration chamber (calibration sleeve) specifications(mm):Φ30 × L150;
6.Radial consistency:0.01℃;
7.Heating time (from ambient temperature to maximum temperature):14minute;
8.Cooling time (from maximum temperature to)ambient temperature):30minute;
9. Automatic stepping: maximum20 steps, adjustable holding time for each point, calibration results can be stored;
10.Maximum power:450W;
11.Instrument size (length)X Width x Height):531×169×432mm;
12. Weight:15.2kg。
The following parameters are limited totype B
13.Current measuring range/Accuracy: 0~24mA/±(0.005%Rdg+0.01%F.S);
14. Voltage measurement range/Accuracy: 0~12V/±(0.005%Rdg+0.01%F.S);
15.RTD resistance measurement range/accuracy: 0~4000Ω/±(0.005%Rdg+0.005%F.S);
16.RTD measurement type: Pt10/50/100/200/500/1000, Cu50/100, ± 0026℃@0℃(Pt100);
17.thermocoupleMV measurement range/accuracy: ± 78mV/± (0.0)05%Rdg+0.005%F.S);
18.Thermocouple temperature measurement type/Accuracy: E/J/K/T/R/S/B/N ± 0.11 ℃@320℃(K);
19.Cold end compensation range/Accuracy: 0~40 ℃/± 0.3 ℃
20.Switch test: dry contact5V,2.5mA;
21.24V circuit power supply: 24VDC ± 10%, maximum 28mA.
The following functional parameters are limitedB. Type C
22.External reference input type/Accuracy: Four wire Pt100400 Ω/± (0.0012% Rdg.+0.0005% F.S.) ± 0.008 ℃ @ 0 ℃;
23.DLC dynamic load compensation: thermocouple multi-point probe, temperature difference measurement.