ROHS halogen-free environmental protection detectorProduct Introduction:
1、 RoHS Six Basic Tests
Users can easily detect and control the six types of substances controlled by RoHS.
Pb、Cd、Hg、 Hexavalent Cr (total tested Cr) PBB PBDE (total tested Br).
2、 Mature classical analysis methods
With the scientific and technological achievements of the national "Seventh Five Year Plan" and "Ninth Five Year Plan" for scientific and technological breakthroughs, and the integration of classic mathematical analysis models with nearly 25 years of experience in analysis and testing applications, reliable, accurate, and stable analysis results are provided to testers.
3、 RoHS halogen-free environmental protection detector UX-2 with major software functions
Highly intelligent design makes operation easier and makes it easy to become a testing expert.
According to the testing situation, the actions and related technical parameters of each operating unit can be automatically set. This ensures the lifespan of the relevant components and avoids human operational errors.
The application of fully automatic high-precision background fitting, multiple regression and other spectral analysis methods makes the detection of complex materials more accurate and convenient.
The specially pre-set spectrum comparison function makes it easy to compare historical spectra with the measured spectra, facilitating accurate analysis of data changes and materials, and further improving the risk response level of enterprises.
Simple and fast data management and report output format, convenient for users to perform related data management and report output.
4、 UX-210 Open Working Curve
Users can easily establish a working curve for risk materials based on their own material conditions, comprehensively improving the correspondence between the working curve and the tested material. Thus significantly improving the detection accuracy of risk substances.
5、 UX-210's rigorous hardware integration and structural design
For core components that may affect the accuracy and stability of the entire machine, all imported original components are used.
Modular design and component selection ensure the stability of overall performance and the ease of operation for future services.
The specially designed primary and secondary filtering system not only ensures the excitation efficiency of harmful elements, but also comprehensively reduces the background intensity as an interference factor, fully improves the peak to background ratio, and significantly reduces the detection limit.
The industry's full radiation triple protection system (software protection, hardware protection, labyrinth structure) fundamentally avoids possible radiation injuries such as malfunctions and misoperations. Ensure that the environmental radiation level of the instrument is lower than the background value during machine operation. (Except for open measurement. A special warning system is used for open measurement of large samples to further ensure the safety concerns of users during the testing process of such substances.).
B、 Technical parameters:
UX-210 is a popular model with a triple radiation protection system; Humanized operation interface; Comprehensive application of experience coefficient method and basic parameter method V6.0 analysis software. RoHS/WEEE related control requirements can be met. The carefully designed open working curve function is particularly suitable for controlling multi material factory processes.
The instrument complies with the technical requirements and specifications specified in the IEC 62321 standard and Chinese environmental standards.
ROHS halogen-free environmental protection detector technical parameters
1. Instrument size: 640 (W) x474 (D) x412 (H) mm
2. Sample cavity size: Small sample cavity: 300 * 300 * 100mm; Large sample cavity: unlimited, less than 30 kilograms
3. Weight: Approximately 48Kg
4. Working environment temperature: 15-30 ℃
5. Relative humidity of working environment: ≤ 85% (no condensation)
6. Analytical element range: K-U
7. Zui low detection limit: Cd/Cr/Hg/Br ≤ 2 ppm, Pb ≤ 5ppm
8. Measurement time: 200-400s (automatically adjusted by the system)
9. Resolution: 149 ± 5eV
10. Input power supply: AC 220V ± 10%, 50Hz
11. Rated power: 800W
● Operating software functions
1. Accurate testing can be conducted on the five harmful elements (Pb, Cd, Hg, Br, Cr) in the RoHS directive;
2. Analysis methods: Comprehensive application of empirical coefficient method and basic parameter method;
3. Open working curve: Users can easily establish targeted risk material curves, improve the correspondence between working curves and risk materials, thereby comprehensively improving detection accuracy and enhancing the accuracy of acceptance judgments.
4. Analysis report: Multiple language formats (Simplified Chinese, Traditional Chinese, English, etc.) and document format reports, such as Excel, PDF, etc., preset standard templates, users can also customize template formats, and all documents can be freely printed and saved;
5. Automatic data saving: All sample test data will be automatically saved, and the test results are traceable; It is easy to compare historical spectra with current spectra, in order to discover the changing trends of incoming materials and establish higher risk prevention capabilities.
6. Stability self check function: It can automatically test the current stability of the instrument in real time;
7. Software safety interlock enables immediate X-ray cut-off treatment for radiation leaks caused by misoperation. Ensure the safety of operators from accidental radiation.
8. Multi language operation interface: English, Simplified Chinese, Traditional Chinese, etc.
● After sales service
Our company provides comprehensive and systematic training by professional technicians until customers become proficient in operating methods and skills. We offer lifelong maintenance services for the instruments we sell.