- Phone
-
Address
1707-1708, T3 Office Building, Huamao Building, No. 11 Wenchang 1st Road, Jiangbei, Huizhou City
Huizhou Huagao Instrument Equipment Co., Ltd
1707-1708, T3 Office Building, Huamao Building, No. 11 Wenchang 1st Road, Jiangbei, Huizhou City
Please consult customer service for the delivery time and price of this product! Thank you!

Non destructive testing instrument micro focus X-ray fluoroscopy inspection device
A direct X-ray inspection equipment equipped with a micro focus X-ray generator and a high-resolution flat panel detector produced by Shimadzu. Through high-definition and wide dynamic range images, subtle internal structures and defects can be observed. In addition, it is possible to easily and quickly switch between perspective/CT modes, and implement various observations according to work requirements. The inspection covered by the Xslicense SMX-6010 ranges from electronic components with continuously decreasing volume to multi-layer solid substrates with increasing density.
■ Tilted CT
When using oblique CT to capture large solid boards, etc
As the sample is on the XY stage, it can be moved closer to the X-ray generator for high magnification imaging.

■ Linear CT
Linear CT imaging of large substrates, etc
If the sample is placed close to the X-ray generator in order to obtain high magnification, it will interfere with the X-ray during CT imaging, making it impossible to perform high magnification photography.

If it is a sample on a substrate, unlike linear CT affected by sample width, oblique CT can perform high magnification photography.

Non destructive testing instrument micro focus X-ray fluoroscopy inspection device
X-ray generator:Equipped with an open tube X-ray generator with a tube voltage of 160kV · 1 μ m resolution. Realize the integration of high-voltage generators without the need for maintenance of high-voltage cables. The automatic adjustment function makes it easier to replace the filament.
※ 1 μ m resolution: JIMA Chart test
X-ray detector:Equipped with a 3-megapixel tablet detector.
5-axis loading platform
In addition to the XYZ axes of the sample stage, the detector will also tilt and rotate. 5-axis linkage, supporting inspection of all angles.

X-ray protective box
Shielding X-rays leaking to the outside of the device (radiation leaking to the outside is less than 1 μ Sv/h). Equipped with a front door locking mechanism, the front door cannot be opened during X-ray irradiation. At the same time, with an interlocking mechanism, the 5-axis loading platform does not move when the door is open.
Collision detection sensor
Collision detection sensors are installed around the X-ray detector, and in case of emergency (sample collision), the drive system stops working.
matching
It can only operate under the condition of AC200 V ± 10% 1.5 kVA (ground resistance below 100 Ω). No need to supply air, cooling water, etc.