Welcome Customer !

Membership

Help

Huizhou Huagao Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Huizhou Huagao Instrument Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    1707-1708, T3 Office Building, Huamao Building, No. 11 Wenchang 1st Road, Jiangbei, Huizhou City

Contact Now

Non destructive testing instrument micro focus X-ray fluoroscopy inspection device

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The non-destructive testing instrument micro focus X-ray fluoroscopy inspection device $r $nXslicer SMX-6010 is a straight irradiation type X-ray inspection equipment, equipped with a produced micro focus X-ray generator and high resolution flat panel detector. Through high-definition and wide dynamic range images, subtle internal structures and defects can be observed. In addition, it is possible to easily and quickly switch between perspective/CT modes, and implement various observations according to work requirements. The inspections covered range from electronic components that are constantly shrinking in size to multi-layered substrates with increasing density.

Product Details

Please consult customer service for the delivery time and price of this product! Thank you!

无损检测仪微焦点X射线透视检查装置

Non destructive testing instrument micro focus X-ray fluoroscopy inspection device


A direct X-ray inspection equipment equipped with a micro focus X-ray generator and a high-resolution flat panel detector produced by Shimadzu. Through high-definition and wide dynamic range images, subtle internal structures and defects can be observed. In addition, it is possible to easily and quickly switch between perspective/CT modes, and implement various observations according to work requirements. The inspection covered by the Xslicense SMX-6010 ranges from electronic components with continuously decreasing volume to multi-layer solid substrates with increasing density.

The principle and characteristics of oblique CT imaging

Can capture plate-shaped samples at high magnification

■ Tilted CT

When using oblique CT to capture large solid boards, etc

As the sample is on the XY stage, it can be moved closer to the X-ray generator for high magnification imaging.


无损检测仪微焦点X射线透视检查装置

■ Linear CT

Linear CT imaging of large substrates, etc

If the sample is placed close to the X-ray generator in order to obtain high magnification, it will interfere with the X-ray during CT imaging, making it impossible to perform high magnification photography.

无损检测仪微焦点X射线透视检查装置

Observing examples

If it is a sample on a substrate, unlike linear CT affected by sample width, oblique CT can perform high magnification photography.

无损检测仪微焦点X射线透视检查装置


Non destructive testing instrument micro focus X-ray fluoroscopy inspection device

System Composition

Our company's self-made X-ray generator and system equipped with various safety mechanisms for easy maintenance,Realize lower cost and safer use

X-ray generator:Equipped with an open tube X-ray generator with a tube voltage of 160kV · 1 μ m resolution. Realize the integration of high-voltage generators without the need for maintenance of high-voltage cables. The automatic adjustment function makes it easier to replace the filament.
※ 1 μ m resolution: JIMA Chart test

X-ray detector:Equipped with a 3-megapixel tablet detector.


5-axis loading platform
In addition to the XYZ axes of the sample stage, the detector will also tilt and rotate. 5-axis linkage, supporting inspection of all angles.

无损检测仪微焦点X射线透视检查装置

X-ray protective box
Shielding X-rays leaking to the outside of the device (radiation leaking to the outside is less than 1 μ Sv/h). Equipped with a front door locking mechanism, the front door cannot be opened during X-ray irradiation. At the same time, with an interlocking mechanism, the 5-axis loading platform does not move when the door is open.

Collision detection sensor
Collision detection sensors are installed around the X-ray detector, and in case of emergency (sample collision), the drive system stops working.

matching
It can only operate under the condition of AC200 V ± 10% 1.5 kVA (ground resistance below 100 Ω). No need to supply air, cooling water, etc.