The RK9950 series programmable leakage current tester is a 5-inch TFT LCD screen display. The tester adopts a 32-bit high-speed MCU and large-scale digital circuit design, with a built-in GB9706.1-2007 (IEC60601-1:1998) human impedance analog network. The board type MD network interface includes MD-A (compliant with GB/T12113-2003, GB4793.1-2007), MD-B (compliant with GB/T12113-2003, GB4793.1-2007, GB4706.1-2005, GB4943)
Product Introduction
RK9950 series programmable leakage current testerFor a 5-inch TFT LCD screen display, the tester adopts a 32-bit high-speed MCU and large-scale digital circuit design, with a built-in GB9706.1-2007 (IEC60601-1:1998) human impedance simulation network,The board type MD network interface includes MD-A (compliant with GB/T12113-2003 and GB4793.1-2007) and MD-B (compliant with GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-2011、GB8898-2011, GB7000.1-2015), MD-C (compliant with GB/T12113-2003, GB7000.1-2015), MD-D (compliant with GB4793.1-2007), MD-E (compliant with GB4943.1-2011, GB4793.1-2007)MD-F (compliant with GB7000.1-2015). Load voltage and current over limit protection; MD network provides multiple fast protections, ensuring safety and reliability. Dynamic and static power testing states; The leakage current test automatically switches between L (phase line) and N (neutral line).It is very easy to set up and operate, and provides PLC remote control interface, RS232C, RS485, USB and other interfaces, which can be easily combined into a comprehensive testing system by users.The tester has the functions of unqualified discrimination, sound and light alarm, and automatic control of testing time, which can meet the needs of production lines or quality inspection
Application field
The tester can be used for leakage current testing of household appliances, electronic instruments, electronic devices, power tools, electric heating appliances and other products
Performance Characteristics
1. Using a 5-inch TFT widescreen (480x272) to display setting and testing parameters, the display content is eye-catching and rich
2. The front panel has a USB interface for copying and copying files
3. The rear panel has a USB interface, which can be used to upgrade software through USB
4. Leakage current test for human network GB9706.1-2007 (IEC60601-1:1998)
5. Test switchable human body network
6. Standard configuration includes PLC interface, RS232 interface, RS485 interface, and upper computer software
7. Featuring a display interface in both Chinese and English, it can meet the needs of different users
8. Built in 16MB Flash
*300V RK9950/RK9950A/RK9950B/RK9950C series programmable leakage current tester
Screen size: 5-inch TFT LCD screen
Communication interface: RS232C, RS485, USB
USB interface: copy, duplicate, and storage functions
Range: 0.001-20.00mA
Product Description Technical Parameters
model |
RK9950 |
RK9950A(500VA) |
RK9950B(1000VA) |
RK9950C |
Basic functions |
screen size |
5-inch TFT LCD screen |
Number keys |
Parameter setting numerical input |
coding switch |
Parameter selection and confirmation function |
Up, down, left, right function keys |
Parameter setting up and down selection function |
LOCK keyboard |
Prevent accidental modification of test conditions or prohibit modification of test conditions |
lock function |
alarm function |
Voice alarm |
communication interface |
RS232C、RS485、USB |
USB port |
Copy, duplicate, and storage functions |
control interface |
HANDLER(PLC) |
test method |
dynamic, static |
load Voltage(AC) |
scope |
0-300V |
30-300V |
30-300V |
50-500V |
precision |
± (2% x display value+0.5V) |
± (1.5% reading+1V) |
± (1.5% reading+1V) |
± (2% reading+1V) |
frequency |
50/60HZ |
45~65HZ |
45~65HZ |
50/60HZ |
load Current(AC) |
maximum |
25A |
2.5A |
4.5A |
25A |
overcurrent protection |
Sound and light alarm, cutting off load output |
Leakage current setting |
Upper limit setting |
scope |
0.001-20.00mA |
Lower limit setting |
scope |
0.000-20.00mA |
Instructions |
The lower limit is set to0 does not make a judgment |
Leakage current test |
Scope and accuracy |
0.001-0.050mA ± (1.5% reading+5 words) (B network) |
0.050-20.00mA ± (1.5% reading+5 words) (B network) |
0.050-20.00mA ± (1.5% reading+5 words) (B network) |
10KHz-1MHz ± (3% reading+5 words) (non-B network) |
MD simulation of human body network |
8 standard networks |
MD-A(GB/T12113-2003、GB4793.1-2007)、MD-B B1(GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-2011、GB8898-2011、GB7000.1-2015)、MD-C(GB/T12113-2003、GB7000.1-2015)、MD-D(GB4793.1-2007)、MD-E(GB4943.1-2011、GB4793.1-2007)、MD-F(IEC60598-1:2014、GB4793.1-2007)、MD-G(GB4943.1-2011、IEC60950-1:2005、GB4793.1-2007、IEC61010-1:2001) |
test time |
scope |
Single timed test:0.1-999S ±1%; The shutdown time is for continuous testing (N-phase testing) |
Instructions |
settingDuring the 0S test, only the N-line is tested and no L conversion is performed |
output power |
No built-in transformer |
500VA |
1000VA |
Three phase without built-in transformer |
External configuration power supply |
Can be connected externally |
built-in |
built-in |
Can be connected externally |
Working temperature and humidity |
0 ° C~40 ° C, (5~80)% RH, less dust |
power supply |
100V-121V,198V-242V,47.5-63Hz |
fuse value |
2A 250V |
8A 250V (slow melting) |
10A 250V (slow melting) |
3A 250V |
weight |
8.5KG |
17.1KG |
19.7KG |
10.4KG |
Standard accessories |
Test line, data line, power lineRS232 to USB connection cable, USB to square port connection cable |
Optional accessories (complete set) |
RK401、RK00031
|