The RK9930 series programmable grounding resistance tester is a high-performance safety tester designed with high-speed MCU and large-scale digital circuits. The output current is controlled by hardware feedback and high-speed MCU technology, ensuring stable and reliable output current. The output current is driven by DDS+power amplifier, and the output waveform is pure with little distortion. It can display current and resistance values in real time, and has software calibration function. It is equipped with PLC interface, RS232C, RS485, USB device, USB Host interface, which can easily form a comprehensive testing system with computer or PLC. Being able to quickly and accurately navigate home
Product Introduction
RK9930 seriesProgrammable grounding resistance testerHigh performance safety testers are designed using high-speed MCUs and large-scale digital circuits. The output current is controlled by hardware feedback and high-speed MCU technology, ensuring stable and reliable output current. The output current is driven by DDS+power amplifier, and the output waveform is pure with little distortion. It can display current and resistance values in real time, and has software calibration function. It is equipped with PLC interface, RS232C, RS485, USB device, USB Host interface, which can easily form a comprehensive testing system with computer or PLC. Capable of quickly and accurately conducting comprehensive safety measurements on household appliances, instruments, lighting appliances, electric heating appliances, computers, and information systems. This instrument complies with IEC60335-1, GB4706.1, UL60335-1 Safety Requirements for Household and Similar Electrical Appliances Part 1: General Requirements UL60950, GB4943, IEC60950 Information Technology Equipment UL60065, GB8898 IEC60065 Safety Requirements for Audio, Video and Similar Electronic Machinery IEC61010-1, GB4793.1 Safety Requirements for Measuring, Control and Laboratory Electrical Equipment Part 1: General Requirements.
Application field
Household appliances: TV, refrigerator, air conditioner, washing machine, dehumidifier, electric blanket, charger, etc
Instruments and meters: oscilloscopes, signal generators, DC power supplies, switching power supplies, and other types of complete machines
Lighting appliances: ballasts, road lights, handheld lights, and other types of lighting fixtures
Electric heating appliances: drills, cutting machines, grinders, welding machines, etc
Performance Characteristics
1. Adopting a 5-inch LCD display, the display parameters are eye-catching and intuitive. DDS digital signal synthesis technology is used to generate accurate, stable, pure, and low distortion waveforms
2. Constant current output: The stability range of the output current is within 1%, avoiding changes in the output current caused by unstable input current voltage and load variations
3. It has an open circuit alarm function. The maximum testing time is 999.9 seconds
4. Using the four terminal method for measurement to eliminate the influence of contact resistance
5. Output frequency 50Hz/60Hz is optional. Equipped with resistance upper and lower limit alarm function
6. Bilingual operation interface in Chinese and English, suitable for different user needs, supports large capacity storage, and adapts to different testing application requirements
30A/40A/60A/120A RK9930/RK9930A/RK9930B/RK9930CProgrammable grounding resistance testerRK9930
Current range: AC (3-30) A
Voltage range: AC 6V Max open circuit voltage
RK9930A
Current range: AC (3-40) A
Voltage range: AC 8V Max open circuit voltage
RK9930B
Current range: AC (3-60) A
Voltage range: AC 12V Max open circuit voltage
RK9930C (Customized)
Current range: AC (3-120) A
Voltage range: AC 12V Max open circuit voltage
Product Description Technical Parameters
model |
RK9930 |
RK9930A |
RK9930B |
RK9930C |
Basic functions |
screen size |
5-inch TFT LCD screen |
Number keys |
Parameter setting numerical input |
coding switch |
Parameter selection and confirmation function |
Up, down, left, right function keys |
Parameter setting up and down selection function |
LOCK keyboard |
Prevent accidental modification of test conditions or prohibit modification of test conditions |
lock function |
alarm function |
Voice alarm |
communication interface |
RS232C、RS485、USB |
USB port |
Copy, duplicate, and storage functions |
control interface |
HANDLER(PLC) |
Output specifications |
current |
current range |
AC (3-32)A |
AC (3-45)A |
AC (3-70)A |
AC (3-120)A |
resolution |
When 10A or above: 0.01A/step; When below 10A: 0.001A/step; |
accuracy |
± (2% set value+0.02A) |
voltage |
voltage range |
AC 6V Max open circuit voltage |
AC 8V Max open circuit voltage |
AC 12V Max open circuit voltage |
frequency |
50/60Hz selectable |
waveform |
sine wave |
ammeter |
Measurement range of ammeter |
AC (3-32)A |
AC (3-45)A |
AC (3-70)A |
AC (3-120)A |
resolution |
When 10A or above: 0.01A/step; When below 10A: 0.001A/step; |
accuracy |
± (2% set value+0.1A) |
ohmmeter |
Resistance meter measurement range |
0-510m Ω, output current 3-10A; 0-120m Ω, output current 10A-30A |
0-600m Ω, output current 3-10A; 0-200m Ω, output current 10A-30A; 0-150m Ω, output current 30A-40A |
0-600m Ω, output current 3-15A; 0-300m Ω, output current 15A-30A; 0-100m Ω, output current 30A50A, 0-60m Ω, output current 50A-60A |
0-600m Ω, 3-15A; 0-300m Ω, output current 15A-30A; 0-80m Ω, output current 30A-60A, 0-30m Ω, output current 60A-120A |
resolution |
When 10A or above: 0.01A/step; When below 10A: 0.001A/step; |
When 10A or above: 0.01A/step; When below 10A: 0.001A/step; |
accuracy |
≤± (2% reading value+1m Ω) |
Timer Range |
0-999.9S, Resolution: 0.1S/step, Accuracy: ≤± 50ms |
compensation method |
Manual or automatic, maximum Offset: 100m Ω Max, accuracy: ≤± (2% reading+1m Ω) |
Determination value setting resistance |
0-510m Ω or 0-600m Ω, resolution: 1m Ω, accuracy: ≤± (2% reading+1m Ω) |
0-600m Ω, resolution: 1m Ω, accuracy: ≤± (2% reading+1m Ω). When the current is ≤ 10A, there is no accuracy requirement for 0-10m Ω |
Upper limit range |
Test time range setting |
0-999.9S, 0 represents continuous |
Working temperature and humidity |
0℃-40℃,≦75%RH |
power supply |
100V-121V,198V-242V,47.5-63Hz |
weight |
12.15KG |
12.9KG |
12.85KG |
35KG |
Standard accessories |
RS232 to USB connection cable, USB to square port connection cableGrounding test clip, power cordRS232 serial port connection cable, upper computer (download) |
RK-12 (120A) test cable, power cable, RS232 serial port connection cableRS232 to USB connection cable, USB to square port connection cable, RK260003A test cable, RK00048 test cable, upper computer (download) |
Optional accessories (complete set) |
RK00031, RK301 grounding point inspection box, RK00070 serial port option LAN port |
RS485 to USB connection cable, RK00031, RK101W grounding point inspection box, RK00070 serial port option LAN port
|