RG-600P Fourier Portable Gas Analyzer

NegotiableUpdate on 01/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The RG-600P Fourier portable gas analyzer can measure the concentration of most gas pollutants, and has the characteristics of high measurement accuracy, high stability and reliability, and fast response time.
Product Details

RG-600P Fourier Portable Gas AnalyzerIt is a portable Fourier transform infrared gas analyzer independently developed by our company for environmental monitoring and industrial site emission gas analysis. This analyzer can measure the concentration of most gas pollutants and has the characteristics of high measurement accuracy, high stability and reliability, and fast response time.

RG-600P Fourier Portable Gas AnalyzerApplication scenarios:

Garbage incineration monitoring (analyzing SO)2、NOx、CO、HCl、HF、NH3Etc.)

Greenhouse gas monitoring (analyzing CO)2、N2O、CH4Waiting for gas concentration

Concentration detection of hydrocarbon components

Motor vehicle exhaust emission testing (analysis of NO, NO)2、CO、CO2、HC)

Measurement of standard gas substance concentration, detection of impurity concentration in standard gas substance

Product Features

Independently developed and designed interferometers for on-site applications, sturdy, durable, and maintenance free for life;

The interference part uses a helium neon laser, which has higher wavelength stability compared to semiconductor lasers;

All metal multiple reflection high-temperature gold-plated gas chamber, corrosion-resistant, highly reliable, and water-soluble gas components such as HCl and NH3Waiting for the loss of no components;

The resolution of the spectrometer is optimized for the gas under test, resulting in high detection accuracy;

The instrument has high internal temperature control accuracy and good environmental adaptability;

Adopting a long-life infrared light source;

Modular design is adopted for light sources, spectrometers, core circuits, gas chambers, etc., with high reliability, good scalability, and easy maintenance.

Sampling probe, sampling pipeline

High temperature probes are suitable for sampling gases containing dust or suspended particles, especially for measurement under non static conditions;

Contains a non corrosive, heated, replaceable filter element;

This filter element is installed in an electrically heated stainless steel filter housing with thermal insulation There is a protective outer box;

Temperature regulation is controlled by PTC heaters;

Connect the heated sample wire directly to the probe housing with a quick connector

High temperature pretreatment

Small size and light weight, convenient to carry;

Automatic temperature control, with a control accuracy of 0.1 ℃;

Heating fault automatically stops sampling to prevent system contamination;

Ensure high-precision filter (0.1u) and system pressure drop of 6mbar. ·Humanized design, easy replacement of filters;




Technical Specifications


project

Specifications

Instructions

SO2measurement range

(0~50~2000)mg/m3

Scalable range

NO measurement range

(0~150~2000)mg/m3

Scalable range

NO2measurement range

(0~150~2000)mg/m3

Scalable range

N2O Measurement range

(0~50~2000)mg/m3


CO measurement range

(0~75~2000)mg/m3

Scalable range

CO2measurement range

(0~25~50)%

Scalable range

HCl measurement range

(0~75~200)mg/m3

Scalable range

HF measurement range

(0~50~200)mg/m3

Scalable range

NH3measurement range

(0~50~200)mg/m3

Scalable range

CHmeasurement range

(0~50~2000)mg/m3

Scalable range

H2O Measurement range

(0~40)%


detection limit

≤1% F.S.


indication error

≤2% F.S.


repetitiveness

Not exceeding 1%


stability

Not more than 2%


Suggested traffic

(2L~3L)/min


24-hour zero drift

Not exceeding ± 2% FS


24-hour range drift

Not exceeding ± 2% FS


response time

not greater than 100s@3L /min

HCl and HF should not exceed 200 seconds

Gas chamber temperature

180℃


Working temperature range

(0~40)℃


ambient humidity

≤98%


Power Supply/Power

220VAC ± 10%/peak 2500W

Average 150W @ ambient temperature 25 ℃


Specification of pneumatic joint

Φ 6mm card sleeve

air intake

Φ 8mm card sleeve

air vent

Φ 6mm quick twist

Optical path blowing

warm-up time

No more than 30 minutes