RF and Universal Frequency Counter/Timer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Keysight 53200 series 350 MHz RF and Universal Frequency Counter/Timer provides built-in data analysis and graphical display capabilities, as well as modern LXI-C and USB connectivity.

Product Details

1.Product Overview:

The Keysight 53200 series includes models such as 53210A, 53220A, and 53230A, and is a new generation 350MHz RF/universal frequency counter/timer with optional 6GHz or 15GHz inputs. This series has a resolution function of *, with a single frequency resolution of up to 12 bits/second on the basis of one second gating. The resolution of a single time interval measurement for the 53230A model reaches 20ps. All models provide built-in analysis and graphic display functions, and are equipped with an intuitive user interface and a large color graphic display screen. Multiple connectivity options to choose from, including LXI-C/Ethernet USB、GPIB, Some models can also be equipped with batteries to improve portability and maintain real-time accuracy. The instrument now comes with a built-in BenchVue software license (BV0011B), making it easier to connect and control the instrument as well as automate test sequences.

2.equipmentapplication:

Automotive electronics: used for the research and testing of automotive electronic systems, such as automotive electronic control units(ECU)、 biography

In the field of communication, it is used to measure parameters such as frequency, period, pulse width, etc. of radio frequency signals in the research, development, production, and maintenance of wireless communication systems to ensure the accuracy and stability of communication signals. For example, monitoring and analyzing the RF signals of base station transmitters and receivers to ensure communication quality.

Radar system: It can accurately measure the frequency and pulse parameters of radar transmission signals, helping to optimize the performance of the radar system. Meanwhile, in the research of radar signal processing and target detection algorithms, accurate time and frequency data support is provided.

Electronic circuit design and testing: In the design verification and performance testing of electronic circuits, the frequency and period of clock signals, as well as various parameters of pulse signals in digital circuits, can be measured to help engineers analyze the working status and performance indicators of the circuit.

Scientific research experiments: Provide high-precision frequency and time measurement tools for physics, electronics, and other scientific research experiments in universities and research institutions, meeting the precise measurement needs of various complex experiments, such as frequency calibration of atomic clocks and time measurement in quantum physics experiments.

3. Equipment characteristics

High resolution and high precision: With high frequency resolution and high precision measurement capabilities, it can meet the requirements for accurate measurement of frequency and time parameters. For example,The 12 bit/second resolution and 20ps time interval resolution of the 53230A model can accurately capture subtle frequency and time changes.

Built in analysis and graphical display functions: providing histogram, trend chart and other graphical display functions, as well as data recording and statistical analysis functions, to help users more intuitively understand the distribution and trend of measurement data, and improve the speed of measurement and analysis346.

Multiple measurement functions: supports frequency, frequency ratio, cycle, time interval, and rise /Measurement of various parameters such as descent time, pulse width, duty cycle, phase, accumulation, etc., to meet the measurement requirements of different application scenarios.

Continuous gapless measurement: capable of continuous measurement /Measurement without gaps and with timestamps on the signal edges, suitable for basic modulation domain analysis, can capture transient changes and modulation information of the signal.

Wide frequency range: The frequency range can reach 350MHz, It can also be extended to 6GHz or 15GHz through options, suitable for signal measurement in different frequency ranges.

Good connectivity: standard configuration LXI-C/Ethernet, USB and other interfaces, some models can choose GPIB interface for easy connection and data transmission with other devices, making it easy to integrate into automated testing systems.

User friendly interface: equipped with an intuitive user interface and a large color graphic display screen, easy to operate, clear display, convenient for users to set parameters and view measurement results345.

4. Some equipment parameters

model

53210A

53220A

53230A

type

1 channel; Optional RF channel

2 universal channels; Optional RF channel

2 universal channels; Optional RF channel

Measurement function

Frequency, frequency ratio, cycle, maximum input voltage /Minimum/Peak to Peak Value

Frequency, frequency ratio, period, time interval, rise /Descent time, signal period, pulse width, duty cycle, phase, accumulation, timestamp/sda

Frequency, frequency ratio, period, time interval, rise /Descent time, signal period, pulse width, duty cycle, phase, accumulation, timestamp/sda

Frequency range (optional)

DC to 350MHz

DC to 350MHz

DC to 350MHz (6 or 15GHz)

frequency resolution

10 bits per second

12 bits per second

12 bits per second

Time interval resolution

Nothing

100ps

20ps

connectivity

USB, LAN, and GPIB

USB, LAN, and GPIB

USB, LAN, and GPIB