| Product features |
| Electrical Design |
PNP |
| output function |
Normally open/normally closed; (Parameters can be set) |
| Sensing distance [mm] |
40...300; (Target object: 100 x 100 mm) |
| communication interface |
IO-Link |
| shell |
rectangular |
| Size [mm] |
M18 x 1 |
| Electrical data |
| Working voltage [V] |
10... 30 DC; (compliant with cULus - Class 2 standard) |
| Current loss [mA] |
< 35 |
| Protection level |
III |
| Reverse phase protection |
have |
| Startup delay time [s] |
< 0.3 |
| Conversion frequency [kHz] |
300 |
| Overall input/output |
| Total number of inputs and outputs |
Number of digital outputs: 1 |
| output |
| output quantity |
1 |
| Electrical Design |
PNP |
| Number of digital outputs |
1 |
| output function |
Normally open/normally closed; (Parameters can be set) |
| Maximum DC voltage drop of switch output [V] |
2.2 |
| Continuous current load of switch output DC [mA] |
100 |
| Switching frequency DC [Hz] |
8 |
| short circuit protection |
have |
| overload protection |
have |
| monitoring scope |
| Sensing distance [mm] |
40...300; (Target object: 100 x 100 mm) |
| Blind spot [mm] |
40 |
| Cylindrical aperture angle [°] |
15; (±2) |
| Maximum deviation of 90 ° angle sensor/target [°] |
± 4 |
| Accuracy/Deviation |
| temperature compensation |
have |
| Delay [%] |
< 1 |
| Switch point offset [%] |
-2...2 |
| Linear error of analog output [%] |
≤ 1 |
| Repetitive accuracy IO Link [%] |
< 0,7 |
| annotation |
The preheating time reaches the indicated value after 20 minutes. |
| repeatability accuracy |
1 % |
| Resolution [mm] |
1 |
| Software/Programming |
| Parameter Settings |
Delay/Window; The second switch point; ON delay and turn off delay; Activate operation; Teach demonstration function; Bright and dark modes |
| interface |
| communication interface |
IO-Link |
| Transfer type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| appearance |
Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel |
| SIO mode |
have |
| Required Material Port Type |
A |
| Minimum processing cycle [ms] |
3.2 |
| IO Link process data (periodic) |
| function |
Position length |
| process value |
16 |
| Device Status |
4 |
| Binary switch information |
2 |
|
| IO Link function (non periodic) |
Apply specific tags; Running hour counter |
| Supported DeviceIDs |
| Operation mode |
Deviceid |
| default |
886 |
|
| annotation |
| For more information, please refer to the IODD PDF file in the 'Download' section |
|
| working conditions |
| Environmental temperature [° C] |
-20...70 |
| Storage temperature [° C] |
-30...80 |
| Shell protection level |
IP 67 |
| Certification/Testing |
| EMC electromagnetic compatibility |
| EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF Electromagnetic Field Radiation |
3 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 Conducted Immunity to Radio Frequency Field Induction |
3 V |
| EN 55011 |
Grade A |
|
| Anti vibration strength |
| EN 60068-2-6 Fc |
(10-55) Hz amplitude of 1 millimeter, oscillation time of 5 minutes, resonance time of 30 minutes per axis or 55 Hz |
|
| impact-resistant |
| EN 60068-2-27 Ea |
30 g 11 ms half sine; 3 impacts in each direction on 3 coordinate axes |
|
| MTTF [year] |
197 |
| UL Certification |
| Ta |
-20...70 °C |
| power supply |
Class 2 |
| Number of files UL |
E174191 |
|
| Mechanical technical data |
| Weight [g] |
97.5 |
| shell |
rectangular |
| Size [mm] |
M18 x 1 |
| Thread code |
M18 x 1 |
| raw materials |
1.4542 (17-4 PH / 630); PBT; PA; Epoxy Glass Ceramic |
| Tightening torque [Nm] |
50 |
| Display/operating components |
| display |
| switch status |
1 x LED, yellow |
| echo |
1 x LED, green |
|
| Teach demonstration function |
have |
| Attachment |
| Scope of supply |
| Fixed nut: 1. Special steel |
|
| annotation |
| annotation |
| According to the working voltage of cULus' power level 2 ' |
|
| packaging unit |
1 piece |
| electrical connection |
| interface |
Connector: 1 x M12 |
| chart |
|

| 1: |
distance |
| 2: |
monitoring scope |
| 3: |
Open/Close Diagram |
| 4: |
Target object 100 x 100 mm |
| 5: |
Target 50% in the detection area |
| 6: |
switch point |
|