Our company's liquid chromatography post column derivatization device has stable quality and high cost-effectiveness, and has been used by over 100 customers in China. The system consists of two SHU liquid pumps and a secondary derivative system, which comply with standards such as "Detection of Carbamate Pesticide Residues in Fruits and Vegetables", "Detection of Glyphosate in Drinking Water", and detection of aflatoxin.
1、 Background introduction:
(1) The T20 type post column derivative system produced by our company has stable quality and high cost-effectiveness, and has been used by more than 100 customers in China.
(2) The system consists of two derivative pumps and a secondary derivative system, which comply with standards such as "Detection of Carbamate Pesticide Residues in Fruits and Vegetables", "Detection of Glyphosate in Drinking Water", and detection of aflatoxin.
2、 Partial customers: Jinan Fruit Research Institute of All China Federation of Supply and Marketing Cooperatives, Dingbian Agricultural Inspection in Shaanxi, Yancheng Center for Disease Control and Prevention, Beihai Center for Disease Control and Prevention in Guangxi, Datong Quality Inspection in Shanxi, Lu'an Quality Inspection in Anhui, Shitong Testing in Qingdao, Guojian in Qingdao, Agricultural Bureau of Boksaier County in Xinjiang, Shenzhen Drug Testing Institute, Jintai Yang Pharmaceutical in Ningxia, Xuzhou Pharmaceutical Group, Lianping County Agricultural Inspection in Guangdong, Lianshan County Agricultural Inspection in Guangdong, Dapu County Agricultural Inspection, Qimei Testing in Wuhan, Zhongheng Testing in Sichuan, Agricultural Product Testing in Sihui City, Sichuan, Kangpaisi Quality Testing in Xi'an, Agricultural and Animal Husbandry Bureau in Ruoergai County, Sichuan, Forestry Academy in Wuwei City, Gansu, Shenyang Testing Center of Northeast Coalfield Geological Bureau, Huacai Testing in Zhejiang, etc.
IIIPost column derivatization device for liquid chromatographyInstrument features:
1. In order to ensure the key performance indicators of the instrument, all core components of the reagent pump are imported, and the proportion of imported components in the entire instrument reaches over 80%; The main indicators for determining SHU liquid pumps are high pressure indicators, and all sealing system components of Huamei Chen Company are imported from the United States. The motor drive that determines the stability and accuracy of flow is imported from Japan. The pulsation damper that suppresses pulsation is designed by Huameichen Company.
2. The derivative system adopts imported derivative pipelines and flow limiters to ensure the stability of the baseline and the separation degree of each measured substance.
4Post column derivatization device for liquid chromatographyTechnical Specifications:
P20 type high-pressure pump
- Flow range: 0.001ml/min~10ml/min
- Flow accuracy:<0.5% (0.5ml/min~10ml/min)
- Flow stability: RSD ≤ 0.06%
- High pressure resistance: 42MPa
Imported motor, imported driver, no mechanical noise, ensuring accuracy
Imported sealing system with strong high pressure resistance
Imported high-efficiency pulsation damper with strong buffering capacity, making pulsation small
- Fully imported liquid pipeline
- Safety control: pressure upper and lower limit control, buzzer alarm, automatic shutdown
T20 chromatography column post derivatization device
- microprocessor chip, high-sensitivity temperature sensor, can achieve temperature setting and control accuracy of ± 0.1 ℃ and maintain stability continuously
- Temperature range: Room temperature~150 ℃
- Setting accuracy: ± 0.1 ℃
- Equipped with sealed 10 meter or 20 meter imported derivative liquid pipeline
analysis project
- Detection of pesticide residues in insecticides (amino acid esters)
- Various toxins (aflatoxin, vomitoxin, shellfish toxin, etc.)
- Detection of herbicide residues (such as glyphosate, BAI glyphosate, Diclofenac, etc.)
- Amino acid analysis (amino acids, taurine)
Amino acid glycosides, polyether antibiotics
BEN Acetone Urine/Wind Diabetes Testing and Screening
Other substances such as biogenic amines, bromate, formaldehyde, chromium VI, guanidine